• Title/Summary/Keyword: 방사선구역

Search Result 133, Processing Time 0.021 seconds

Radiation Exposure on Radiation Workers of Nuclear Power Plants in Korea : 2009-2013 (국내 원전 종사자의 방사선량 : 2009-2013)

  • Lim, Young-khi
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.162-167
    • /
    • 2015
  • Although the perfomance indicators of the nuclear power plants in Korea show optimal, it requires detailed analysis and discussion centered on the radiation dose. As analysis methods, analysis on the radiation dose of nuclear power plants over the past five years was assessed by comparing the relevant radiation dose of radiation workers and per capita average annual radiation dose of the world's major nuclear power stations was also analyzed. The radiation workers over the annual radiation dose limit of 50 mSv were not. The contrast ratio of the radiation exposure according to the reactor type was the normal operation of PHWR was 6.2% higher than those of the PWR. This shows the radiation work of PHWR during normal driving operation is much more than those of PWR. According to the Performance Indicators of the World Association of Nuclear Operator, the annual radiation dose per unit in 2013 showed 527 man-mSv of Korea is the best country among the major nuclear power generating states, the world average was 725 man-mSv. The annual per capita radiation dose is about 80% less than 1 mSv of the public dose limit and also the average per capita dose showed a very low level as 0.82 mSv. Workers in related organizations showed 1.07 mSv, the non-destructive inspection agency workers showed 3.87 mSv. The remarkable results were due to radiation reduced program such as development of radiation shielding and radiation protection. In conclusion, the radiation exposured dose of nuclear power plants workers in Korea showed a trend which is ideally reduced. But more are expected to be difficul and the psychological insecurity against the operation of the nuclear power plants is existed to the residents near the nuclear power plants. So the radiation dose reduction policy and radiation dose follow up study of nuclear power plants will be continously excuted.

Metastatic Malignant Fibrous Histiocytoma in Lung -One Case Report- (폐로의 전이성 악성 섬유성 조직구종 -1예 보고-)

  • 이석열;이만복;이길노;고은석
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.671-674
    • /
    • 1999
  • At OPD follow-up in December 1998, chest x-ray of a 42-year-old female showed a solit ary pulmonary nodule at a superior basal segment in the right lower lobe. After percut aneous transthoracic needle aspiration failure, wedge resection of the superior basal segment of lower lobe in right lung was performed for diagnosis and therapy. Three years ago, she had received surgery to remove a mass in the left buttock. The mass was pathologically diagnosed as malignant fibrous histiocytoma. She subsequently received 4500 rad radiotherapy for 35 days. Pathology confirmed metastatic malignant fibrous histiocytoma of the lung.

  • PDF

Early Therapeutic Effects of Cyberknife Radiosurgery on Trigeminal Neuralgia (삼차신경통에 대한 사이버나이프 방사선수술의 조기 치료 효과)

  • Mun Seong-Kwon;Choi Ihl-Bohng;Kang Young-Nam;Jang Ji-Sun;Kang Ki-Mun;Choi Byung-Ock
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.88-95
    • /
    • 2006
  • Purpose: We evaluated whether Cyberknife radiosurgery is an effective and safe method of therapy for medically intractable trigeminal neuralgia (TN). Materials and Methods: We retrospectively analyzed the outcome of 26 patients, who failed to surgery or were not suitable candidates for invasive intervention and were treated by Cyberknife radiosurgery between March 2004 and May 2005. Radiosurgery doses of $60{\sim}64 Gy$ were delivered to the 80% isodose line prescribed to an 6 mm length of the nerve, sparing the most proximal 3 mm away from the trigeminal nerve root entry zone (median dose: 64 Gy). Results: Follow-up period was $3{\sim}15$ months (median follow-up period: 9 months) Preliminary results from a cohort of 26 patients undergoing Cyberknife radiosurgery for TN showed that pain relief was achieved in 50% (13/26) of patients within the first 24 hrs after treatment. At last follow-up, 96.2% (25/26) of patients reported early pain relief within 7 days. Treatment failure developed in 2 of 26. Poor response occurred in one patient and relapse was observed in the other patient. 3 patients had hypoesthesia (11.5%), which was the only complication observed with any of our patients. Conclusion: With these results, authors assumed that Cyberknife radiosurgery for TN could be one of safe and effective therapeutic methods.

Development of Qualitative Evaluation of Medical Radiation Protective Apron (의료 방사선 방호용 앞치마의 정성적 평가법 개발)

  • Lim, Hui-Gyeom;Kim, Sang-Hyun;Kim, Tae-Hyung;So, Woon Young;Lee, Tae Hui;Kim, Seung Chul;Kim, Jin-Tae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.453-460
    • /
    • 2017
  • This study proposes effective quality control and maintenance method by developing a new qualitative evaluation method of apron for medical radiation protection. As an experimental material, one of 0.45 mm lead and 100 of 0.45 mm Pb aprons were used and irradiated under the conditions of a tube voltage of 75 kVp and a tube current of 12.5 mAs to obtain an image. and using the Image J program, PSNR values were compared and analyzed. The results showed that there were 40 aprons (less than 11dB), 55 aprons (less than 11dB, less than 30dB), and 5 aprons (30dB or more). In addition, the dose showed a normal distribution for the apron, and 5 aprons with PSNR less than 11dB and 30dB or more were selected and divided into 8 zones, and these groups were statistically significant.

Study in Occupational Exposure to Radiations and Radioactive Isotopes (방사선 및 방사성동위원소 근로자 피폭실태 연구)

  • Lee, Du-Yong;Kim, Kwang-Jin;Park, Hee-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.247-255
    • /
    • 2009
  • This study aims to provide basic data for establishing the safety and health plan by investigating the exposure conditions in the facilities registering business about handling radiations and radioactive isotopes in Korea. dose levels(working space, worker location) of the workers in 153 facilities were measured using surveymeter, and individual exposure concentration[(shallow dose(SD), depth dose(DD)] in 27 facilities using thermal luminescence dosimeter(TLD). In accordance with the measurement results by business type[fire fighting prevention business(FFPB, n=10), financial insurance business(FIB, n=3) and other facilities(n=140)] using surveymeter, those three business type groups showed difference (p<0.000). Dose levels of worker location for FFPB and FIB were significantly higher than 10.0 ${\mu}Sv$/hr, the allowable standard for radiations and radioactive isotopes, and they were higher 109.3 times(p<0.000) and 187.5 times(p<0.000) than those in other facilities. The concentration of TLD[FFPB(n=10), other facility (n=17)] in DD of FFPB was significantly higher than that in other facility(p=0.05). In accordance with the analysis result on relationship between surveymeter and TLD, the dose on working space and worker location(r=0.406, p<0.05), worker location dose and SD(r=0.453, p<0.05), worker location dose and DD(r=0.553, p<0.01), and SD and DD(r=0.927, p<0.001) had all related each other. It is urgently required to change FFPB and FIB from the facilities requiring registration for handling radiations and radioactive isotopes to the facilities that shall get permission for handling radiations and radioactive isotopes by reestablishing the legal administration area, for safety and health of radiation occupants.

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF

Analyzing Image Quality and Disinfection Effectiveness of Alcohol Gel Application in Ultrasound Scans (초음파 스캔에서 알코올 겔 적용 시 화질과 소독효과 분석)

  • Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.365-372
    • /
    • 2024
  • To analyze the image quality and disinfection effectiveness of alcohol gel application in ultrasound scans, we varied the application of alcohol gels with different alcohol content from ultrasound gels. The image quality analysis compared the Dead zone, axial and lateral resolution, sensitivity, and gray scale changes using the ATS-539 phantom, while the disinfection effectiveness analysis was performed by swabbing the three cover faces of convex probe used in clinical practice, collecting specimens and enrichment culture them for 24 hours before identification with Gram stain. image quality analysis showed that all items, regardless of the alcohol content, produced images that were not different from the ultrasonic gel application images, and pathogens such as staphylococcus aureus, streptococcus, and enterococcus were detected on all probes, and all were extinction by the application of alcohol gel. The application of alcohol gel during ultrasound examination was meaningful in terms of image quality maintenance and disinfection effect, and if the results of this study are further studied and commercialized, the application of alcohol gel as an alternative to ultrasound gel will be very useful in clinical examinations because it can consider not only image quality but also infection prevention.

An Evaluation on the Radiation Shielding of the Radwaste Drum Assay Facility (방사성폐기물드럼 핵종재고량 평가시설 구축에 따른 방사선차폐 영향평가)

  • Ji, Young-Yong;Kwak, Kyung-Kil;Hong, Dae-Seok;Shon, Jong-Sik
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.10 no.2
    • /
    • pp.117-123
    • /
    • 2012
  • In order to dispose of the LILW(low and intermediate level radioactive waste) stored at KAERI, the radwaste drum assay system will be introduced to evaluate the radioisotopes inventory of stored drums. At present, the construction project of the dedicated assay facility to operate it and carry out routine maintenance of that equipment has been conducting at the radwaste treatment facility. Since that facility will be constructed in front of a 1st radwaste storage facility as well as the radwaste drums to be assayed and the transmission source in the radwaste drum assay system are in that facility, they could act as the radioactive sources and then, would affect the dose rate at the inside and the outside of the facility. Therefore, the radiation shielding should be evaluated through the concrete wall near to the radioactive sources whether the wall thickness is sufficient against the regulations. In this study, the radiation safety for the concrete wall around the radiation controlled area in the radwaste drum assay facility was evaluated by the MCNP code. From the evaluation results, the thickness of those concrete walls which are under consideration of about 30 cm was enough to shield the radiation from the radioactive sources.

Analysis of Minimum Detectable Activity Concentration of Water Samples and Evaluation of Effective Dose (물 시료의 최소검출가능 농도 분석과 유효선량 평가)

  • Jang, Eun-sung;Kim, Yang-su;Lee, Sun-young;Kim, Jung-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.7
    • /
    • pp.857-862
    • /
    • 2020
  • In March 2011, a tsunami off Japan caused radioactive material that had seeped into the sea from the Fukushima nuclear accident to flow to the Pacific Ocean, causing pollution to sea life. For a comparative evaluation with the area surrounding the site of a nuclear power plant by the release of radioactive materials, an area 20 to 30 km away from the emergency protection plan area was selected as a comparative point considering weather conditions, population distribution, etc. In addition, the government intends to analyze the minimum detection radiation received by residents around the nuclear power plant and evaluate the effective dose. Analysis of tritium radiation from water samples showed that most of the samples were not detected and that 0.0014 % to 0.777 % of the annual legal standard of 1 mSv for the general public had little effect on the human body. Therefore, the measurement and analysis of water samples around the nuclear power plant site is expected to help relieve anxiety, such as exposure to the general public and neighboring residents due to radiation release.

액체폐기물 처리계통 고선량 폐필터 장기저장설비

  • Lee, Sang-Tae;An, Won-Seok;Mun, Cheol-Ung;Lee, Eun-Hak;Im, Wan-Seok
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2007.05a
    • /
    • pp.65-66
    • /
    • 2007
  • 원자력 발전소 방사선 관리구역 1차 계통수의 수질 정화 후 발생된 고선량 폐필터를 방사능 붕괴 후 잡고체 폐기물로 처리하기 위한 장기저장시설 내 설치 될 설비 임. 동 설비는 자동화공정을 기본으로 한정된 공간에 다량의 폐필터를 가장 효율적으로 저장 할 수 있는 최적의 설비이며, 폐필터 장입, 인출 시 작업시간단축, 작업자 피폭저감, 오염확산 방지는 물론 폐기물을 감용시켜 폐기물처리, 처분 비용 절감에 기여하고자 한다.

  • PDF