• Title/Summary/Keyword: 방사선구역

Search Result 132, Processing Time 0.025 seconds

Evaluation of the Size of Emergency Planning Zone for the Korean Standard Nuclear Power Plants (한국표준형 원전에 대한 방사선비상계획구역 범위 평가)

  • Jeon, In-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.215-223
    • /
    • 2003
  • Against major release of radioactive material in nuclear power plant, Emergency Planning Zone(EPZ)s are typically established around nuclear power plants to effectively perform the public protective measures. The domestic methodology to determine the size of the EPZ is similar to that of Japan established in 1980, where calculations were based on the conservative accident source term. The objective of this study is to re-evaluate the validity of established EPZ, the area within the radius of $8{\sim}10km$ around domestic nuclear power plants, using the source terms covering full spectrum of accidents obtained from PSA study of ULJIN 3&4. To evaluate the risks of health effects, the computer code MACCS2(MELCOR Accident Consequence Code System2) was used. The result shows that the existing EPZ can reduce the probability of early fatality adequately for most of the source term categories(STCs) except for STC-14 and STC-19. In case of STC-14 and 19, the evacuation distance of 16km and 13km, respectively, are required. These distances can be reduced by improving emergency preparedness since the sensitivity studies for the public protective actions show that the magnitude of early fatality is largely affected by the time delays in notification and evacuation.

Evaluation of Impacted Maxillary Canine Position Using Panoramic Radiographs and Cone-beam Computed Tomography (파노라마 방사선사진과 CBCT를 이용한 매복 상악 견치의 위치 평가)

  • Daeyoung, Hwang;Namki, Choi;Seonmi, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.4
    • /
    • pp.442-452
    • /
    • 2022
  • The purpose of this study was to compare the mesio-distal and vertical position of impacted maxillary canines on panoramic radiographs with the labio-palatal position of impacted canines and root resorption of adjacent teeth on CBCT (Cone-Beam Computed Tomography). A total of 54 patients with 69 impacted maxillary canines were included in this study. On panoramic radiographs, the mesio-distal (Sector I - V), and vertical position, and angulation of impacted maxillary canines were evaluated. Labio-palatal position and root resorption of adjacent teeth were evaluated on CBCT. Labial impaction of canines was most frequent in panoramic sector I. Impaction within the arch was most frequent in sector I and II. Palatal impaction was most frequent in sector III, IV, and V. Mesially positioned canines on panoramic radiographs tended to be palatally impacted. Most of the root resorption of adjacent teeth occurred in sector III, IV, and V (p < 0.05). Canines with low angulation on panoramic radiographs tended to be palatally impacted and resorb the roots of adjacent teeth. The vertical position of impacted canines on panoramic radiographs was not statistically significant with respect to labio-palatal position and root resorption of adjacent teeth on CBCT. Analysis of the mesio-distal position and angulation of impacted maxillary canines on panoramic radiographs can be used to predict the labio-palatal position of impacted canines and root resorption of adjacent teeth.

A Study on the Public Evacuation Time Estimates for Radiological Emergency Plan and Preparedness of Wolsong Nuclear Power Plant Site (방사선 비상계획을 위한 월성원전 주변 주민 소개시간 예측 연구)

  • Lee, Gab-Bock;Bang, Sun-Young;Chung, Yang-Geun
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.79-88
    • /
    • 2007
  • When an accident occurs at nuclear power plant and radionuclide material is released to the area around the plant, public evacuation is considered as a measure to protect the safety of the residents nearby. This study draws factors required to estimate evacuation time and make estimation of the time to evacuate all residents from the EPZ of Wolsong site in consideration of traffic condition in the neighborhood and on the basis of field data around the site for each factor. The traffic capacity and the traffic volume by season were investigated for the traffic analysis and simulation within EPZ of Wolsong site. As a result, the background traffic volume by season were established. To estimate TGT(Trip Generation Time), the questionnaire surveys were carried out for resident and transient. The TSIS code was applied to traffic analysis in the events of daytime/night and normal/adverse weather under normal day/summer peak traffic condition. The results showed that the evacuation time required for total vehicles to move out from EPZ took generally from 118 to 150 minutes. The evacuation time took longer maximum 17 minutes at night than daytime during summer peak traffic.

Remote Visualization of Radiation Information based on small Semiconductor Sensor Modules (소형 반도체 센서모듈 기반 방사선정보 원격 가시화기술 연구)

  • Lee, Nam-Ho;Hwang, Young-Gwan;Heu, Yong-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.876-879
    • /
    • 2012
  • In this paper we studied the radiation detection technology which described the radiation level distribution in high radiation area with remotely and safely. The designed radiation mapping system was composed of radiation nodes and radiation station. The radiation nodes could sense the radiation dose values with pMOSFET radiation sensors and transmit them to the radiation station. At the radiation station the received radiation values were merged with a geometric information and visualized at the virtual graphic location. For the functional verification of the above system, we attached the radiation nodes to each corner in our laboratory, executed the mapping tests, and confirmed the designed functions finally.

  • PDF

"하나로"의 채널유동 차단사고시 방사선 환경 영향평가

  • Lee, Jong-Tae;Han, Mun-Hui;Hwang, Won-Tae;Lee, Byeong-Cheol;Park, Cheol
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.867-873
    • /
    • 1995
  • 개방수조형 연구로인 하나로에서 가상적인 채널유동 차단사고에 따른 방사능 방출시의 환경영향을 부지 기상자료 측정결과를 이용하여 고공방출과 지표 면방출의 두가지 경로에 대해 평가하였다. 계산 결과, 지표면방출이 고공방출보다 피폭선량이 크게 나타났으나, 두 경우 모두 제한구역(EAB) 및 저인구지역(LPZ) 경계에서의 피폭선량 허용기준치를 만족하였다. 그리고 비상계획구역은 800 m로 설정하면 적절함을 입증하였다.

  • PDF

해외 기술 동향 - CCTV

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.33 no.5
    • /
    • pp.98-99
    • /
    • 2013
  • 발전소의 주요 구역과 시설을 계속적으로 모니터링 할 수 있는 내방사선 카메라 시스템은 그 중요성이 점점 커지고 있고, 전력 송출 중단 시간 (outage time)을 줄이고 작업자의 방사선 피폭량을 최소화하는 데에 기여할 것으로 원전 운영자들은 기대하고 있다.

  • PDF

Measurement of Spatial Dose Distribution for evaluation operator dose during Neuro-interventional Procedures (두경부 질환의 인터벤션 시술 시 시술자의 피폭선량평가를 위한 공간선량측정에 관한 연구)

  • Han, Su-Chul;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.323-328
    • /
    • 2016
  • The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in $18.1{\pm}10.5%$, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.