• Title/Summary/Keyword: 방사선감시

Search Result 145, Processing Time 0.028 seconds

Clinical Implementation of an Eye Fixing and Monitoring System with Head Mount Display (Head Mount Display (HMD)를 이용한 안구의 고정 및 감시장치의 임상사용 가능성 확인)

  • Ko, Young-Eun;Park, Seoung-HO;Yi, Byong-Yong;Ahn, Seung-Do;Lim, Sang-Wook;Lee, Sang-Wook;Shin, Seong-Soo;Kim, Jong-Hoon;Choi, Eun-Kyung;Noh, Young-Ju
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • A system to non-invasively fix and monitor eye by a head mounted display (HMD) with a CCD camera for stereotactic radiotherapy (SRS) of uveal melanoma has been developed and implemented clinically. The eye fixing and monitoring system consists of a HMD showing patient a screen for fixing eyeball, a CCD camera monitoring patient's eyeball, and an immobilization mask. At flrst, patient's head was immobilized with a mask. Then, patient was Instructed to wear HMD, to which CCD camera was attached, on the mask and see the given reference point on its screen. While patient stared at the given point in order to fix eyeball, the camera monitored Its motion. Four volunteers and one patient of uveal melanoma for SRS came into this study. For the volunteers, setup errors and the motion of eyeball were analyzed. For the patient, CT scans were peformed, with patient's wearing HMD and fixing the eye to the given point. To treat patient under the same condition, daily CT scans were also peformed before every treatment and the motion of lens was compared to the planning CT Setup errors for four volunteers were within 1mm and the motion of eyeball was fixed within the clinically acceptable ranges. For the patient with uveal melanoma, the motion of lens was fixed within 2mm from daily CT scans. An eye fixing and monitoring system allowed Immobilizing patient as well as monitoring eyeball and was successfully implemented in the treatment of uveal melanoma for SRS.

  • PDF

Review of Contamination and Monitoring of On-site Groundwater at Foreign Nuclear Power Plants due to Unplanned Release (비계획적 방출에 의한 해외 원전 부지 지하수 오염 및 감시 기술현황 분석)

  • Sohn, Wook;Lee, Gab-Bok;Yang, Yang-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.2
    • /
    • pp.124-131
    • /
    • 2013
  • Utilities have tried to ensure that radiological hazards to the environment and residents are kept as low as reasonably achievable by monitoring and controlling planned releases. However, since groundwater contamination was reported to occur due to unplanned releases mostly in the United States nuclear power plants, the interest of the stakeholders has increased to a point where it is now one of the most important issues in the United States nuclear power industry. This paper aims to help to implement an effective on-site groundwater monitoring program at domestic nuclear power plants by briefing the experiences of the United States nuclear power plants on groundwater contaminations and groundwater monitoring, and responses of the United States nuclear industry and regulator body for them.

Automatic Analysis of Gamma Ray Spectra for Surveillance of the Nuclear Fuel Integrity (핵연료 건전성 점검을 위한 감마선 스펙트럼의 자동 분석)

  • Cho, Joo-Hyun;Yu, Sung-Sik;Kim, Seong-Rae;Hah, Yung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.555-561
    • /
    • 1994
  • The program of performing a fast and automatic analysis of gamma ray spectra obtained by a Multi-Channel Analyzer (MCA) is developed for the surveillance of the nuclear fuel integrity. The integrity of the nuclear fuel is confirmed by the measurement of the radiation level of the reactor coolant through the real time monitoring and the periodic sampling analysis. In Yonggwang nuclear power plane 3 and 4, the Process Radiation Monitoring System (PRMS), which is a real time monitoring system, provides a measure of the fuel integrity. Currently, its spectrometer channel can identify only one radionuclide at a time since the signal processing unit of the spectrometer channel is a Single Channel Analyzer (SCA). To improve the PRMS, it is necessary to substitute the MCA for the SCA The program is operated in a real time mode and an on-demand mode, and automatically performed for all procedures. The test results by using the National Bureau of Standards (NBS) mixed standard source are in good agreement with those from Canberra System 100 which is a commercial MCA Consequently, the developed program seems to be employed for automatic monitoring of gamma rays in nuclear power plants.

  • PDF

Quantitative Assessment of the Radiation Exposure during Pathologic Process in the Sentinel Iymph Node Biopsy using Radioactive Colloid (방사성 콜로이드를 이용한 감시림프절 생검 병리처리과정에서 방사선 피폭의 정량적 평가)

  • Song, Yoo-Sung;Lee, Jeong-Won;Lee, Ho-Young;Kim, Seok-Ki;Kang, Keon-Wook;Kook, Myeong-Cherl;Park, Weon-Seo;Lee, Geon-Kook;Hong, Eun-Kyung;Lee, Eun-Sook
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.309-316
    • /
    • 2007
  • Purpose: Sentinel lymph node biopsy became the standard procedure in early breast cancer surgery. Faculty members might be exposed to a trace amount of radiation. The aim of this study is to quantify the radiation exposure and verify the safety of the procedure and the facilities, especially during pathologic process. Materials and Methods: Sentinel lymph node biopsies with Tc-99m human serum albumin were performed as routine clinical work. Exposed radiation doses were measured in pathologic technologist, nuclear medicine technologist, and nuclear medicine physician using a thermoluminescence dosimeter (TLD) during one month. We also measured the residual radioactivities or absorbed dose rates, the exposure distance and time during procedure, the radiation dose of the waste and the ambient equivalent dose of the pathology laboratory. Results: Actual exposed doses were 0.21 and 0.85 (uSv/study) for the whole body and hand of pathology technologist after 47 sentinel node pathologic preparations were performed. Whole body exposed doses of nuclear medicine physician and technologist were 0.2 and 2.3 (uSv/study). According to this data and the exposure threshold of the general population (1 mSv), at least 1100 studies were allowed in pathology technologist. The calculated exposed dose rates (${\mu}$ Sv/study) from residual radioactivities data were 2.47/ 22.4 ${\mu}$ Sv (whole body/hand) for the surgeon; 0.22/ 0 ${\mu}$ Sv for operation nurse. The ambient equivalent dose of the pathology laboratory was 0.02-0.03 mR/hr. The radiation dose of the waste was less than 100 Bq/g and nearly was not detected. Conclusion: Pathologic procedure relating sentinel lymph node biopsy using radioactive colloid is safe in terms of the radiation safety.(Nucl Med Mol Imaging 2007;41(4);309-316)

On-line Gamma Monitoring System for Environmental Radiation Measurement around KAERI-site (KAERI 부지 주변의 환경선량 측정을 위한 온라인 감마선량 감시시스템)

  • Lee, Chang-Woo;Park, Doo-Won;Lee, Won-Yun;Choi, Yong-Ho;Hong, Kwang-Hee;Kim, Sam-Rang;Lee, Hyun-Duk;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.2
    • /
    • pp.147-156
    • /
    • 1994
  • On-line gamma monitoring system around KAERI-site was set up to monitor the radiation fluctuations in environment. Data on gamma exposure rates measured by the ionication chamber in the monitoring posts are transmitted to a computer of central control station with. radio telemetry transmission modem and monitored in real time. Radio telemetry transmission system is economical and reliable on handling and storing of data. This monitroing system can triger an early warning system in the event of abnormal radiation levels.

  • PDF

Detection Properties of Irradiated Dried Seafoods Using PSL and ESR (PSL과 ESR 분석에 의한 건조수산물의 방사선 조사 여부 판별 특성 연구)

  • Song, Beom-Seok;Han, In-Jun;Yoon, Young-Min;Choi, Soo-Jeong;Kim, Jae-Kyung;Park, Jong-Heum;Jeong, Il-Yun;Lee, Ju-Woon;Kim, Byeong-Keun;Kim, Kyu-Heon;Kim, Jae-Hun
    • Journal of Radiation Industry
    • /
    • v.6 no.2
    • /
    • pp.119-123
    • /
    • 2012
  • The detection properties of gamma-irradiated (0~10 kGy) dried seaweed, dried shrimp, and seasoned dried filefish were investigated by photo-stimulated luminescence (PSL) and electron spin resonance (ESR). PSL could be used as a detection method on irradiated dried seaweed and dried shrimp as they showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples with doses above l kGy. However, PSL could not be applied to detect irradiated seasoned dried filefish, because gamma-irradiated sample at 10 kGy even yielded photon counts less than 700 counts/60 s (negative). The ESR spectroscopy for only dried shrimp revealed specific signals derived from free radicals captured in the shell of shrimp. As a result, it is considered that PSL or ESR methods for detection of gamma-irradiated dried shrimp and only PSL can be used to detect gamma-irradiated seaweed. Furthermore, it is considered that hydrocarbon analysis of seasoned dried filefish containing fat by GC/MS and Thermo Luminance (TL) analysis of dried seaweed should be studied for detection of irradiation.

원자력分野 에서의 破壞力學 現況 -법적 요구사항을 중심으로 (II)-

  • 송달호;손갑헌
    • Journal of the KSME
    • /
    • v.21 no.1
    • /
    • pp.21-31
    • /
    • 1981
  • 원자력발전소의 원자로냉각재 압력경계의 건전성과 안정성을 확보하기 위하여 법적 요구조건을 설정함에 있어 파괴역학이 어떻게 적용되었는 가를 설명하였다. 이를 요약하면 다음과 같다. 1) 압력경계에 사용되는 재료의 $RT_{NDT}$를 정의하였다. 이는 무연성천이온도와 같은 개 념의 것으로, 앞으로 재료의 파괴인성은 이 $RT_{NDT}$에 대한 상대온도의 함수로 주어진다. 2)비연성파괴를 방지하기 위한 설계조건으로서 선형탄성 파괴역학에 근거한 조건식을 인용하였다. 여기서 조건식이란 능력확대계수의 합계가 어떠한 조건에서도 이러한 조건식을 만족한다는 것을 해석적으로 확인하고 규제당국의 승인을 받아야 한다. 3) 가동중검사에 발견된 결함으로 합격수준을 초과하는 것은 파괴역학적으로 해석하여 구조적 으로 안전하다는 것은 파괴역학적으로 해석하여 구조적으로 안전하다는 것을 입증하여야 한다. 이때 결함은 원자로의 가동과 더불어 성장하므로 수명기간중 피로파괴에 이를 것인지의 여부도 평가하여야 한다. 이때의 대조균열성장률은 Paris의 power law에 따른다. 4) 고속중성자 (E>1. 0MeV)에 의한 조사취화를 감시하기 위하여 감시시험계획을 사전에 수립 하고 이에 따라 감시시험을 수행하여 조사에 수립하고 이에 따라 감시시험을 수행하여 조사에 의한 원자로용기 재료의 파괴인성의 저하를 평가하여 이를 고려한 충분한 안전여유를 갖는 운 전조건 즉, 압력-온도 한계곡선을 산출하여야 한다. 이때의 취화 정도는 DELTA. $RT_{NDT}$ 와 Upper Shelf Energy의 감소로 나타낸다. 또한, 압력-온도 한계곡선은 선형관성 파괴역학에 입각한 조건식을 이용하여 해당 온도에서의 압력을 산출한다. System을 개발 사용하기 위하여 기존 전자계산소를 이용하는 방법이 바람직하며 System의 도입은 자체운영을 결정하기 전에 경제적인 여건 등 여러가지 문제를 검토하여야 한다. 특히 Turn Key Base로 System를 도입할 경우에는 System의 도입목 적과 사용빈도, 앞으로의 확장성 현재 설계및 생산 과정과의 마찰가능성, 유지보수문제 등을 신 중히 검토하여야 한다. 이제 기계공업도 전자계산기를 이해하고 사용하므로 서 발전할 수 있는 단계가 되었다. 예로부터 좋은 공구를 개발하여 적절히 사용하는 것이 기계공업 발전의 첩경이 었다. 전자계산기는 현대 기술이 개발한 가장 강력하고 사용하기 좋은 공구이다.점에서 피로구열의 안정성장을 논하고, 과거 10여년간의 피로 crack문제에 대한 연구방법, 실험방법 등을 소개하는 방향으로 고 를 진행시켜 나가겠다.에 그 효과가 증대됨을 알 수 있었다.적용한 임상실험이 수행되어야 할 것이다. 또한 위치결정에서 획득한 좌표값의 정확성을 알아보기 위해서 팬톰을 이용한 방사선조사 실험이 추후에 실행되어져야 할 것이다. 그리고 제작된 프레임에 Rotating X선 시스템과 내부 장기의 움직임을 계량화하고 PTV에서의 최적 여유폭을 설정함으로써 정위 방사선수술 및 3 차원 업체 방사선치료에 대한 병소 위치측정과 환자의 자세에 대한 setup 오차측정 결정에 도움이 될 수 있을 것이라고 사료된다. 상대적으로 우수한 것으로 나타났으며, 혼합충전재는 암모니아의 경우 코코넛과 펄라이트의 비율이 7:3인 혼합 재료 3번과 소나무수피와 펄라이트의 비율이 7:3인 혼합 재료 6번에서 다른 혼합 재료에 비하여 우수한 것으로 나타났다. 4. 코코넛과 소나무수피의 경우 암모니아 가스에 대한 흡착 능력은 거의 비슷한 것으로 사료되며,

  • PDF

Assessment of Occupational Dose to the Staff of Interventional Radiology Using Monte Carlo Simulations (몬테카를로 방법을 이용한 중재방사선시술자에 대한 선량평가)

  • Lim, Young-Khi
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.213-217
    • /
    • 2014
  • Medical operations and diagnosis using interventional radiology techniques have been increased. The management and monitoring of occupational radiation exposure to the staff of interventional radiology become important, specially because they stand in close proximity to the patient. The operational radiation protection quantity, Hp(10) which can be obtained from personal dosimeter do not always represent the effective dose to the staff. So, in this study, to estimate the critical organ doses to the staff of interventional radiology, Monte Carlo calculations with mathematical human phantom and dose measurements with personal dosimeters were carried out for the major interventional radiology procedures using C-arm. Results showed that the values of Hp(10) measured by personal dosimeters were higher than critical organ doses which were calculated. And the calculated dose to thyroids was much higher than those of other critical organ doses. For the proper radiation protection of the medical staff of interventional radiology, additional radiation protection for thyroids as well as for whole body shielding like wearing a lead apron should be considered.

Radio-sensitivity of Dark-striped Field Mice, Apodemus agrarius, as a Biological Dosimeter in Radio-ecological Monitoring System (환경 방사선 생물학적 감시 지표로서 야생 등줄쥐의 방사선 감수성)

  • Kim, Hee-Sun;Nishimura, Y.;Kim, Chong-Soon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.25-32
    • /
    • 2006
  • This study examined the possibility of using dark-striped field mice as a biological indicator for the environmental radio-surveillance. For this study, dark-striped field mice were caught from five areas of Kyonggi, Kyongsang, Chungchong and Cholla provinces. The external morphological characteristics and isoenzymic types of dark-striped field mice were studied after they were captured. Among the external morphological characteristics, the dark-brown coat, dark back stripe, head-to-tail length, tail length, and ear length matched the taxonomical characteristics of dark-striped field mice. The analyses on L-lactate dehydrogenase, aspartate aminotransferase, and malate dehydrogenese revealed that one species of dark-striped field mice, called Apodemus agrarius, was inhabitated throughout a wide range of Korea. On the other hand, the frequency of micronuclei in peripheral polychromatic erythrocytes to survived mice after irradiation also analyzed. The LD50/30 of A. cgrarius and ICR mice were approximately 5 Gy and 7.9Gy, respectively. The results of the study reveal that wild A. asrarius have a high potential as a biological monitoring system to determine the impact of radiation in areas such as those within the vicinity of nuclear power plants.

  • PDF