• Title/Summary/Keyword: 방사상대

Search Result 164, Processing Time 0.026 seconds

Radiation Characteristic Analysis of Fresnel Zone Plate Lens Array (프레넬 존 플레이트 렌즈 배열의 방사특성 해석)

  • Kim, Tae Yong;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.53-54
    • /
    • 2014
  • By using geometrical structure of Fresnel lens, it can be applied with receiver antenna and geodetic system. In this paper, radiation pattern from fresnel lens array of Soret type is calculate by the FDTD method. For simplicity, fresnel lens should be located linearly and considered to be dielectric rod with a relative permittivity.

  • PDF

Influence of the Monitoring Interval and Intake Pattern for the Evaluation of Intake (내부피폭 감시주기 및 섭취형태가 방사성핵종 섭취량 평가에 미치는 영향)

  • Jong-Il Lee;Tae-Young Lee;Si-Young Chang;Jai-Ki Lee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 2004
  • A variety of factors such as the pattern of intake (acute or chronic), monitoring interval and the characteristics of the radionuclides could have a significant influence on the estimates for the intake and internal dose. The relative differences of the assessed intakes based on the assumption of an acute intake to that of a chronic intake were evaluated by using the predicted bioassay quantity in the whole body or organs for an acute and chronic intake through the inhalation of $^{125}$ I, $^{137}$ C, $^{235}$ U with the AMAD of 1 ${\mu}{\textrm}{m}$ and 5 ${\mu}{\textrm}{m}$ for the monitoring intervals of 7, 14, 30, 60, 90, 120, 180, 360 days, respectively, The relative difference of the assessed intakes based on the intake pattern is affected by the monitoring interval, radionuclide and absorption type, but the particle size has little influence on the difference of the assessed intakes based on the intake pattern. The maximum monitoring interval, which is defined as the monitoring interval that the relative difference of the assessed intakes based on the assumption of an acute intake to that of a chronic intake is less than 10%, is 60 d for $^{125}$ I with Type F, 180 d for $^{137}$ C with Type F, 90 d for $^{235}$ U with Type M, and 360 d for $^{235}$ U with Type S. It was concluded that an intake pattern has little influence on the estimates of the assessed intake in the case where the monitoring interval is shorter than the maximum monitoring interval for each radionuclide.

  • PDF

Relative ratio about dose value of thermoluminescence and optical stimulated luminescence dosimeter according to exposed condition in diagnostic radiation (진단방사선의 노출 조건에 따른 열형광선량계와 광자극형광 선량계의 선량값 상대비)

  • Kang, Yeonghan;Kwon, Soonmu;Kim, BooSoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.499-505
    • /
    • 2012
  • The purpose of this study was to find out the difference of radiation dose value through energy, exposure number, fluoroscopy time, the number of days of exposed scatter X-ray when TLD and OSLD is used in diagnostic radiology. The difference of value were measured by relative ratio and interval. Energy makes high relative ratio of TLD($1.81{\pm}0.41$) than OSLD($1.40{\pm}0.26$), exposure number makes high of OSLD($1.40{\pm}0.26$) than TLD($2.10{\pm}0.10$). There are no significant differences between relative ratio of TLD and OSLD in fluoroscopy time and the number of days of exposed scatter X-ray. But interval of relative ratio in the number of days of exposed scatter X-ray was narrowed in less 0.2. That means, the measurement of scatter X-ray could more confident in TLD and OSLD than the measurement of direct ray. In conclusion, we have to recognize the relative ratio of TLD and OSLD could be vary depending on exposed condition of radiation. And in some cases, double test of TLD and OSLD get more creditable results of dose value.

A Study on the Collection Efficiency of A Tritium Bubbler (삼중수소 버블러의 포집효율에 대한 고찰)

  • Shin Jae-sin;Lee Seung-Ho;Park Kwang-Ryeol
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.172-181
    • /
    • 2005
  • Collection Efficiency of a tritium bubbler being used at domestic nuclear power plants was studied. Equilibrium is attained while tritium vapour in air passes through the bubbler. When a lot of gas sample passes through the bubbler, the tritium concentration of water is raised and volume of water is decreased or increased. These phenomena give effect to the collection efficiency. Estimation of the tritium concentration of the water agreed with our experiments. If relative humidity is higher than 0.5, the efficiency becomes lower than 1 and if relative humidity is lower than 0.5, the efficiency becomes higher than 1, provided collected tritium is evaluated with original volume of the water. Though the relative humidity is riot 0.5, the efficiency can be maintained near 1 by making $\frac{saturated\; water\; vapour(cm^3_w)\times volume \; of \; gas \; sample(cm^3)}{volume\; of\; water(cm^3)}$ small

  • PDF

Cracking of Rice Caused by Moisture Migration during Storage (쌀의 저장중 수분이동에 의한 균열현상에 관한 연구)

  • Mok, Chul-Kyoon;Lee, Sang-Ki
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.164-170
    • /
    • 1999
  • Cracking of rice caused by moisture migration during storage under different relative humidity conditions was investigated for the establishment of safe storage condition of rice. Rice was cracked when a large difference in equilibrium relative humidity $({\Delta}ERH)$ between the rice and the environment was present. External and internal cracks were generated as the results of moisture desorption and adsorption, respectively. The external cracks by moisture desorption generated in all directions and shaped irregularly, while the internal cracks by moisture adsorption did in radial direction and showed a typical shape. The cracking trend could be analyzed by the Weibull function, and the cracking constant increased with ${\Delta}ERH$. The frequency of cracked rice increased linearly with In $({\Delta}ERH)$. The critical crack-inducing ${\Delta}ERH$ was $11.3{\sim}16.4%$ during desorption and $10.8{\sim}17.1%$ during adsorption. A diagram for the safe storage of rice was developed with respect to the initial moisture content and the water activity of rice.

  • PDF

Analysis of Accuracy of Apparent Activity According to Calibration Method for High Dose Rate Brachytherapy Source (측정용 전리함에 따른 고 선량율 근접치료용 방사성 선원의 겉보기 활성도의 정확도 비교 분석)

  • Huh, Hyun-Do;Choi, Jin-Ho;Choi, Sang-Hyoun;Kim, Seong-Hoon;Kim, Woo-Chul;Kim, Hun-Jeong;Lee, Re-Na;Kim, Kum-Bae;Hong, Seong-Eon;Shin, Dong-Oh
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.305-312
    • /
    • 2008
  • The aim of this study is to introduce the accuracy of Ir-192 source's apparent activity using the well-type chamber and the Farmer-type ionization chamber in the high dose rate brachytherapy. We measured the apparent activity of Ir-192 that each medical center in the country has and the apparent activity of calibration certificate provided by manufacturer is compared with that by our experimental measurement. The number of sources used for the activity comparison was 5. The accuracy of the measured activity was in the range of -2.8% to -1.0% and -2.1% to 0.2% for the Farmer-type chamber system (Jig) and for the well-type, respectively. The maximum difference was within 1.0% for comparison with two calibration's tool. Our results demonstrate that well-type chamber as wall as Farmer-type chamber is a appropriate system as the routine source calibration procedures in HDR brachytherapy. Whenever a new source is installed to use in clinics, by periods, a source calibration should be carried out.

  • PDF

Radiation Therapy for Superior Vena Cava Syndrome (상대정맥증후군의 방사선치료)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.78-84
    • /
    • 2005
  • Purpose: The studied the effect of such variables as the symptom improvement rate, survival and prognostic factors on the treatment results of radiation therapy for Superior Vena Cava Syndrome (SVCS). Materials and Methods: From 1988 to 2003, seventy two patients with SVCS were treated with radiation therapy at the Department of Radiation Oncology, Keimyung University Dongsan Medical Center. The patients' ages ranged from 10 to 83 years old with the median age being 61, and sixty four patients were male. For the causes of the SVCS, 64 patients had lung cancer, four had metastatic lung cancer, two had malignant lymphoma and two had thymoma. The radiotherapy was delivered with 6-MV X-rays and all patients received above 900 cGy up to 6,600 cGy, with the median dose being 4,000 cGy The follow-up periods were from 1 to 180 months with a median of 5.6 months. Results: The main clinical manifestations were dyspnea ($84.7\%$), facial edema ($81.9\%$), arm edema ($22.2\%$), neck vein distension ($25\%$), hoarseness ($12.5\%$) and facial plethora ($5.6\%$). Eighty percent of patients achieved excellent to good symptom improvement and $19.4\%$ experienced minimal improvement. The median survival period was 5.1 months, and overall survival rates were $17.7\%$ at 2 years (2YOS) and $14.8\%$ at five years (5YOS) for all the patients. The median survival period, the two and five year disease free survival rates were 4.3 months, $16.7\%$ and $13.4\%$ for the lung cancer patients, respectively. The total tumor dose was a statistically significant survival factor on the univariate analysis for the patients with lung cancer (2YSR; > 30 Gy, $25.6\%$, $\leq$ 30 Gy $6.7\%$, p<0.01). On the multivariated analysis, a higher total tumor dose (p<0.01) and younger age (p<0.05) were statistically significant factors of survival for the lung cancer patients. Patients with NSCLC showed better survival than did the patients with SCLC, but this was not statistically significant (p > 0.05), Conclusion: Radiation therapy for the patients with SVCS due to malignancy could be an effective treatment. We considered that radiation therapy above 30 Gy of the total tumor dose may improve survival for SVCS due to lung cancer.

Mediastinal Cavernous Hemangioma (상대정맥에 발생한 해면상 혈관종 -1례 보고-)

  • 김동원;이재영;배철영;신원선;맹대현;곽영태;이신영
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.69-72
    • /
    • 1998
  • Mediastinal hemangioma is a rare tumor and only few cases have been reported in the literatures. We have experienced one case of cavernous hemangioma occuring at the superior vena cana. The patient was a thrity-five year old female with no specific symtoms except palpable cystic mass in the right cervical area. A routine chest radiography showed an upper mediastinal mass. Computed Tomography showed about 4$\times$5 cm sized cystic mass communicating to the superior vena cava 2 cm above of the veno-atrial junction. After the evaluation, surgical excision was performed and the pathologic diagnosis was confirmed to cavernous hemangioma. Postoperative course was uneventful and the patient has been followed up without any problems.

  • PDF

Temperature Distribution Measurement of High-pressure Mercury Lamp using Spectroscopic Method (분광 분석법에 의한 고압 수은등의 온도분포 측정)

  • 김상용;김창섭;지철근
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.3 no.4
    • /
    • pp.41-48
    • /
    • 1989
  • 두 분광선의 상대휘도를 이용하는 분광 분석법에 의하여 고압 수은등의 온도분포를 측정하였다. 관경 방향의 휘도분포를 구하기 위해 측정된 분광휘도를 Abel변환을 수행하여 관경방향의 분광휘도로 변환하였다. 사용된 온도결정법은 LTE가 성립한다는 가정하에 같은 종류의 원자로부터 방사되는 두 분사광선의 상대휘도 비교에 의한 절대온도 결정법이고 가시광선 영역에 존재하는 수은의 분광선들 중 두가지 조합이 사용되었다. 250W 고압 수은등으로 실험한 결과 6300[K]까지의 축 중심부 온도가 측정되었으며 아아크의 수축현상이 잘 관찰되었고 중심에서 5[mm]까지의 영역에서 LTE가 성립함을 실험적으로 확인하였다. 본 논문에서 사용한 실험방법이 타당하게 적용될 수 있는 중심 부근에서의 온도분포는 이단계(two-step) 온도분포에 근사함을 알 수 있었다.

  • PDF

Left-Handedness 특성 Metamaterial 구조의 마이크로파 부품과 안테나 개발에의 적용 기술

  • Gang, Seung-Taek
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • 본고를 통해 초고주파 이론과 공학 분야는 물론 물리학, 재료공학의 기초 학문 분야에서도 지대한 관심을 모으고 있는 Metamaterial(MTM) 구조에 대해 조명하고자 한다. 먼저 MTM의 핵심이라고 할 수 있는 Left-Handedness(LH) 왼손 전파 법칙과 LH 발생 재질인 Double Negative(DNG) 재질에서의 전파 특성을 상대 유전율과 상대 투자율 평면에서 확인하고, 일반 매질인 Double Positive(DPS)형인 오른손 전파 법칙 Right-Handedness(=RH) 매질과의 결합(Composite Right-and Left-Hnaded=CRLH)에서 얻어지는 특징들을 살펴본다. 특히 DPS와 DNC의 결합에서 얻을 수 있는 음의 공진과 0차 공진(Zero-Order Resonance)을 언급하고 ZOR을 응용한 RF 부품의 소형화와 특성 개선사례를 소개한다. 또한, 안테나와 전자파 산란 특성에 MTM의 특수한 성질을 이용하여, 크기를 줄이거나 표면파를 억제하거나 혹은 방사 개구를 확대 또는 렌즈 특성을 얻어낸 사례도 언급된다 그리고 LH 특성은 아니지만 MTM 계열인 ENG(Epsilon Negative), MNG(Mu Negative), ENZ(Epsilon Near Zero)를 응용한 예들을 보이고, MTM 관점에서 FSS(Frequency Selective Surface )의 특성을 논의하고, 그간에 발표된 대표적 MTM 연구 결과에 대한 소개를 마치고자 한다.