• Title/Summary/Keyword: 방류구

Search Result 115, Processing Time 0.024 seconds

A Comparative Study on Hydraulic Jump and Specific Energy Losses at Downstream According to the Weir Discharge Types (보 유출형태에 따른 하류부 도수 및 비에너지 손실에 관한 비교 연구)

  • Park, Hyo-Seon;Yoon, Geun-Ho;Koo, Bon-Jin;Choi, Gye-Woon
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.149-157
    • /
    • 2013
  • The weirs built so far are mainly overflow type weirs overflowing to the upstream. Main advantages of overflow type weirs are, effective water resources management and easy design, construction and maintenance due to many accumulated studies. However, due to the special feature of the overflow type weir where water overflows through the upstream of the weir, the silt coming from the upstream is not discharged to the downstream of the weir. This increases the river bed and reduces the reservoir capacity, and as a result, the weir loses its function. A underflow type weir with a water gate has been implemented in order to solve such sediment deposit and weir maintenance problems. However due to the design problem of recently constructed underflow type weirs, the river bed of the downstream of a weir has been scoured. And this leds to a structural problem. In this study, the flow characteristics of overflow type weirs and underflow type weir, hydraulic jump length analysis depending on change of water depth and the amount of specific energy loss generated per unit length depending on a weir type have been compared and analyzed, for the effective design and management of the weirs. The experiment results show that, when identical upstream conditions of underflow type weir and an overflow type weir were maintained, the hydraulic jump length was up to twice longer with Fr(Froude number) 3.5 of the hydraulic jump length at the underflow type weir, and the hydraulic jump length gradually decreased as the downstream water depth increased. The comparative analysis result of the amount of specific energy loss generated per unit length showed that the amount of energy loss per unit length was twice higher for an overlfow type weir than a underflow type weir. Therefore, in case of a underflow type facility, an additional energy reduction facility is determined to be necessary for safety of water construction structures.

Hydraulic Analysis of Air-core Patterns with Various Discharge and Improving Inlet Part of the Underground Bypass Model (유량변화와 지하방수로 유입구모형의 개선에 따른 공기공동양상의 수리학적 분석)

  • Park, Sung Won;Kim, Hyung-Jun;Rhee, Dong Sop
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.369-369
    • /
    • 2016
  • 홍수피해 저감을 위한 지하방수로나 지하저류지 등은 홍수 방어를 위한 도심 내의 토지 확보 부담을 줄이며, 집중 호우 발생 시 내수를 초기에 신속하게 배제하여 제내지 침수 피해를 줄이는데 효율적으로 활용된다. 미국 및 일본, 홍콩과 같은 외국에서는 이미 지하방수로 및 지하저류지를 활용한 홍수피해 저감방안을 수립하여 활용하고 있으며, 최근 국내에서도 치수 계획 수립 시 지하방수로 혹은 지하저류지 시설 도입이 활발히 검토되고 있으나 적용사례가 전무하여 제반기술이 부족하고 많은 시행착오가 예상된다. 제반설계기술의 경우는 구조적인 방안이 모색되어야 하며 대표적으로, 지하방수로 유입구 형상이, 동일한 흐름조건에 대한 유량배제효율에 가장 지배적인 영향인자로 알려진 바 있으며 다양한 유입구 형상설계방안이 기존 실험적 연구 및 외국 설계지침에 제안된 바 있다. 지하방수로는 접근 수로를 통해 유입된 유량이 유입구를 지나며 가속되어 와류 흐름을 형성하며 수직 갱도로 유입되는 구조를 갖기 때문에 지하방수로의 방류 효율을 높이기 위해서는 유입구에서 흐름 특성을 파악하는 것이 중요하다. 이때 유입흐름특성이 사류일 경우 혹은 급격하게 유입 유량이 많아지는 경우 수직 갱도 내에 공기 공동이 형성되어 구조물 파손, 와류의 발생으로 인한 배제효율 감소 등의 피해를 야기할 수 있으므로 수리학적으로 규명할 필요가 있다. 따라서 본 연구에서는 지하방수로의 기존 유입구형상에 대한 장단점을 비교하고, 개선점을 적용하여 수리모형을 제작하여 개수로 실험장치에 설치하고 다양한 유입흐름조건에 따라 수리실험을 수행하였다. 그 결과 유입흐름조건에 따라 발생하는 유입구의 공기 공동의 발달 및 소멸 그리고 규모변화를 정량적으로 분석하여, 유입부의 가능 단면적이 큰 수직갱도인 경우, 유량배제 효율이 감소되는 분석결과에 적절하게 일치하였으며, 본 연구결과는 향후 지하방수로 설계의 제반기술의 수립 시 효율적인 활용이 가능하다.

  • PDF

A Study on the Determination of Optimal Location and Size for Underground Sluiceway Design (지하방수로 설계를 위한 적정 위치선정 및 규모 결정에 관한 연구)

  • Lee, Jong-Tae;Lim, Taek-Sun;Hur, Sung-Chul;Park, Sang-Sik
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.5
    • /
    • pp.137-145
    • /
    • 2008
  • In this study, to reduce the flood damage caused by flood discharge exceeding project flood, the primary technology was applied to determining the optimal location and size for underground sluiceway. The Jungrang Stream was selected for this study because the stream was overflowed and the embankment section of the stream was destroyed owing to localized torrential rainfall in 1998 and 2001. Considering 200-year frequency storm, the inlets of the underground discharge channel were located at Seoul City limits, the confluence of Danghyun Stream, Wolgye 1-gyo, and the confluence of Mukdong Stream. The outlets were located at the estuary of Jungrang Stream and rightbank of Banpo Bridge in Han River. The transverse discharge according to the variation of overflow depth at the inlet of underground discharge channel was estimated and the effect of inundation reduction was analyzed. To examine the appropriate scale of the underground discharge channel, the 8 operation methods for the management of outlet discharge were compared considering four rules (only storage, the constant discharge rate, the constant discharge volume, and the mixture of the constant discharge rate and discharge volume). As a result, the effect of inundation reduction was most significantly improved when the inlet was located at the confluence of Danghyun Stream. The appropriate size of underground sluiceway for 200-year frequency storm was studied, and as a result, the appropriate diameters of the underground discharge channel were 12 m in case of only storage(Rule D), 9m in 50% of discharge(Rule E), 8 m in constant discharge volume(Rule F), and 7 m in mixture method(Rule G). This investigation process can be applied to design the underground discharge channel when the inundation damage is significant in coastal area due to embankment overflow. The underground discharge channel in Jungrang Stream can also be used as an underground road to link Seoul City to Uijeongbu City during dry season.

Thermal Effluent Effects of Domestic Sewage and Industrial Wastewater on the Water Quality of Three Small Streams (Eung, Chiljang and Buso) during the Winter Season, Korea (동계 저온기의 소하천 수질에 미치는 하·폐수의 온배수 영향)

  • Soon-Jin, Hwang;Jeon, Gyeonghye;Eum, Hyun Soo;Kim, Nan-Young;Shin, Jae-Ki
    • Korean Journal of Ecology and Environment
    • /
    • v.50 no.2
    • /
    • pp.238-253
    • /
    • 2017
  • The sewage and wastewater (SAW) are a well-known major source of eutrophication and greentide in freshwaters and also a potential source of thermal pollution; however, there were few approaches to thermal effluent of SAW in Korea. This study was performed to understand the behavioral dynamics of the thermal effluents and their effects on the water quality of the connected streams during winter season, considering domestic sewage, industrial wastewater and hot spring wastewater from December 2015 to February 2016. Sampling stations were selected the upstream, the outlet of SAW, and the downstream in each connected stream, and the water temperature change was monitored toward the downstream from the discharging point of SAW. The temperature effect and its range of SAW on the stream were dependent not only on the effluent temperature and quantity but also on the local air temperature, water temperature and stream discharge. The SAW effects on the stream water temperature were observed with temperature increase by $2.1{\sim}5.8^{\circ}C$ in the range of 1.0 to 5.5 km downstream. Temperature effect was the greatest in the hot spring wastewater despite of small amount of effluent. The SAW was not only related to temperature but also to the increase of organic matter and nutrients in the connected stream. The industrial wastewater effluent was discharged with high concentration of nitrogen, while the hot spring wastewater was high in both phosphorus and nitrogen. The difference between these cases was due to with and without chemical T-P treatment in the industrial and the hot spring wastewater, respectively. The chlorophyll-a content of the attached algae was high at the outlet of SAW and the downstream reach, mostly in eutrophic level. These ecological results were presumably due to the high water temperature and phosphorus concentration in the stream brought by the thermal effluents of SAW. These results suggest that high temperature of the SAW needs to be emphasized when evaluating its effects on the stream water quality (water temperature, fertility) through a systematized spatial and temporal investigation.

Estimation of the Freshwater Advection Speed by Improvement of ADCP Post-Processing Method Near the Surface at the Yeongsan Estuary (ADCP 표층유속 자료처리방법 개선을 통한 영산강 하구 표층 방류수 이류속도 산정)

  • Shin, Hyun-Jung;Kang, Kiryong;Lee, Guan-Hong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.3
    • /
    • pp.180-190
    • /
    • 2014
  • It has been customary to exclude top 10-20% of velocity profiles in the Acoustic Doppler Current Profiler (ADCP) measurement due to side lobe effects at the boundary. To better understand the mixing in the Yeongsan estuary, the freshwater advection speed (FAS) was recovered from highly contaminated ADCP data near the surface. The velocity profiles were measured by using ADCP at two stations in the Yeongsan estuary during August 2011: one was located in front of the Yeongsan estuarine dam and the other was deployed near Goha Island. The FAS was recovered from the ADCP data set by applying rigorous post-processing methods and compared with the sediment advection speed (SAS). The SAS was determined by the peak time difference of suspended sediment concentration between two stations in the channel, divided by the distance of two stations. The FAS and the SAS showed very similar value when the freshwater discharge was greater than $2.0{\times}10^7$ ton and the SAS was a bit greater when the freshwater discharge was smaller. Since the FAS was on average about 0.8 m/s greater than the velocity at 0.8 of water depth from the bottom, the net discharge, estimated with recovered FAS and integrated over water depth and tidal cycle, was directed seaward during the high discharge contrary to the onshore direction of the net discharge estimated with 0.8 of water depth from the bottom. Moreover, the velocity shear and Richardson number changed when the FAS was used. Thus, the importance of the true FAS is appreciated in the investigation of the surface layer stability. If currents, temperature and salinity were observed for longer time in the future, it could be possible to more accurately understand the formation and decay of stratification as well as the suspended sediment transport processes.

Thermal Dispersion Analysis Using Semi-Active Particle Tracking in Near Field Combined with Two-Dimensional Eulerian-Lagrangian Far Field Model (근역에서 부력입자추적모형을 적용한 Eulerian-Lagrangian 결합에 의한 온수확산)

    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.10 no.2
    • /
    • pp.73-82
    • /
    • 1998
  • In order to simulate surface discharged heat dispersion in costal area, a 2-dimensional Eulerian-Lagrangian model for far field and semi-active particle tracking random walk model in near field has been combined. The mass of discharged heat water in near field has treated as particles with buoyancy and this is eventually converted to horizontal additive dispersion in random walk equations. This model is applied to both a simplified coastal geometry and a real site. In simple application it can simulate plume-like characteristics around discharging point than a near field-model, CORMIX/3. Actual application in the Chonsu Bay shows farther spreading of heat water in near field comparing the observed data, and this shows that the developed model might be applied with satisfaction.

  • PDF

A Study on the Water Circulation Enhancement inside Harbor Utilizing Wave Energy (파랑에너지를 이용한 항내 해수순환증진에 대한 연구)

  • 오병철;전인식;정태성;이달수
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.14 no.3
    • /
    • pp.209-221
    • /
    • 2002
  • In the present paper, a method which enhances the circulation of harbor waters by using wave energy was investigated. The overflow levee was selected as a coastal structure helping the harbor circulation, and was applied to Jeju-outer-port site so as to estimate its effectiveness quantitatively in probabilistic point of view. It was assumed that sea water influx rate through the overflow levee into the harbor depended upon wave height and tidal level and a functional relationship among them was calculated using the results of hydraulic experiment. The probability distribution of water influx could be obtained from hindcasted wave data and measured tidal elevations at Jeju harbor. The Gamma distribution was appeared to best fit the estimated influx distribution, and the optimal location of the levee was discussed. Finally, water quality purification effect was investigated by computing the contaminant material dispersion according to whether the levee was or not.

A Flood Mitigation Safety Analysis for Yongdam Dam against the Future Climate Change (미래 기후변화에 대한 용담댐 치수안전도 분석)

  • Kang, Boo-Sik;Kim, Young-Oh;Lee, Seung-Jong;Kang, Dong-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.312-317
    • /
    • 2006
  • 지역규모의 기후변화 모의결과를 이용하여 금강유역 용담댐의 홍수기 치수안전도에 대한 민감도분석을 수행하였다. 기후변화 모의에 사용된 SNURCM(Seoul National University Regional Climate Model)은 미국 National Center for Atmospheric Research의 Community Climate System Model의 전지구모형을 기반으로 spectral nudging 기법을 사용한 공간해상도 30 km, 연직 21층의 지역기후모형이다. 기후변화 시나리오로는 SRES 'B1'이 사용되었으며 과거 control run에 대한 기후모의 정확도 분석을 통하여 SNURCM 기상자료를 관측치와 비교한 결과 면적강우량을 다소 과소추정하였고 이점을 감안하여 SNURCM의 일 모의결과에 보정 계수를 적용하였다. 하천유출량은 SSARR 모형을 이용하여 SNURCM 모의가 수행된 전체기간을 $1980{\sim}1999$년과 $2000{\sim}2019$년으로 20년씩 나누어 용담댐 일 유입량을 산정하여 통계분석을 실시하였고 과거와 미래 20년 동안을 비교하여 본 결과 (1) 유량의 평균보다는 분산이 미래 20년 동안 증가하여 가뭄과 홍수에 대한 위험도가 증가함을 알 수 있었고, (2) 특히 연최대유량 또한 미래 20년 동안 상당히 증가하여 홍수기 치수대책이 더욱 중요해질 것으로 판단되었다. 마지막으로 용담댐 운영은 범용 시스템분석 도구인 STELLA(System Thinking Experimental Learning Laboratory with Animation) 상에서 GUI로 구현하여 유입량 변화에 따른 용담댐 치수안전도 변화를 모의해 보았다. 용담댐의 홍수기 운영은 저수지 수위가 제한수위를 초과하기 시작하면 Rigid ROM 발효하여 방류량을 결정하도록 구성하였고, 무효방류(spill)가 일어나는 현상을 실패로 가정하여 이에 대한 신뢰도(reliability), 회복도(resiliency), 그리고 심도(vulnerability)를 치수안전도 지표로 계산하였다. 전체기간을 1980년${\sim}$1999년, 2000년${\sim}$2019년, 2000년${\sim}$2009년, 그리고 2010년${\sim}$2019년까지 총 4구간으로 나누어 결과를 도출하였으며 예상한 바와 같이 후반기 20년 동안에 세 가지 지표가 취약해 지는 것을 확인할 수 있었고, 특히 2000년부터 2009년까지 10년 동안에는 더욱 취약해짐을 확인할 수 있었다.

  • PDF

Analysis of Inundation Causes in Urban Area based on Application of Prevention Performance Objectives (도시유역에서의 방재성능목표 적용과 침수원인 분석)

  • kim, Jong-Sub
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.16-23
    • /
    • 2016
  • The purpose of this study is to analyze quantitatively the inundation causes by applying the prevention of performance objectives using the urban storm water runoff model XP-SWMM. The model was built by using DTM and storm sewer-network with the storm sewer and geo-data of the study area as input-data to assess the current performance of prevention. An analysis of the causes of the inundation by the frequency and the rainfall-duration. As a result, lack of pipe capacity due to flooding, as well as inundation heavier that the backwater rainfall occurs due to the rise of water level of outside. For solve the inundation damage, It is necessary to improvement pipe of capacity lack and installation of a flood control channel.

2-Dimensional Hydrodynamic and Water Quality Analysis of Water Quality of the Geum River using EFDC and WASP7.2 (EFDC-Hydro와 WASP7.2를 이용한 금강하류 2차원 동역학수리 및 수질 모의)

  • Seo, Mi-Jin;Seo, Dong-Il;Lee, Yong-Sung;Yun, Jin-Ho
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1953-1956
    • /
    • 2008
  • 본 연구에서는 금강의 하류부의 시간적 공간적 수질변화를 자세하게 분석하기 위하여 3차원 수리동역학 모델인 EFDC 와 비정상상태 수질모델인 WASP 7.2와 를 연계 적용하였다. 본 연구의 대상 구간은 금강하류 부중 대청댐 조절지 방류구 지점부터 공주의 정안천 유입 직전까지 총 48km의 구간이다. 하천의 수심별 수질은 일정하다고 가정하였으나 폭방향의 수질은 좌 중 우로 3개의 소구간으로 나누고 하천의 흐름 방향으로 나누어 전체적으로는 2차원적으로 구분하였다. 하천의 바닥 형상을 이용하여 모델 격자를 구성하였으며 수리모델은 건교부의 수위자료를 이용하여 보정하였고 수질자료는 환경부의 수질측정망 자료를 이용하여 보정하였다. 2차원 수리동역학-수질 연계모델링 결과, 대전 갑천이 유입되고 난 후의 청원지점에서 그리고 청주지역의 영향을 포함하는 미호천이 유입되고 난 연기 지점 그리고 본 연구의 최하류인 공주지점에서는 하천의 폭 방향으로 상당한 수질 차이가 있음을 확인하였다. 이는 대전 갑천 또는 청주 미호천 등이 유입된 이후 효과적으로 혼합되지 않는다는 것을 의미한다. 이는 해당지역의 수질시료 채취 위치에 따라 수질에 현격한 차이가 있을 수 있다는 것을 나타내며, 현재 환경부 수동측정망의 시료채취 방법을 고려하여 볼때 하천수질의 대표성을 나타낼 수 있는가 하는 문제의 차원에서 매우 심각하게 받아들여져야 할 것으로 생각된다. 한편, 현재 우리나라에서 시행되고 있는 오염총량관리제나 대부분의 환경영향평가에서는 하천의 폭 방향의 수질 차이에 대한 고려가 전무하며 이에 대한 전면적인 재검토가 시급하다고 판단된다.

  • PDF