• Title/Summary/Keyword: 발전소 배수로

Search Result 120, Processing Time 0.021 seconds

Design of Sedimentary Rock Slopes in River Diversion Works (가배수로 터널공사의 퇴적암 사면 안정화 설계)

  • Jee, Wang-Ruel
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.17-32
    • /
    • 1998
  • The Bakun hydroelectric project includes the construction of a hydroelectric power plant with an installed capacity of 2,520MW and a power transmission system connecting to the existing transmission networks in Sarawak and Western Malaysia, The power station will consist of a 210m height concrete faced rockfill dam. During the construction of the dam and the power facilities the Balui river has to be diverted by three diversion tunnels with a length of some 1,400m each. The inner diameter of the tunnels is 12m and the tunnel width is 16m at the portal area. This paper describes the stability analysis and design methods for the open cut rock slopes in the inlet and outlet area of the diversion tunnels. The geotechnical parameters employed in stability calculations were given as a function of four. defined Rock Mass Types (RMT) which were based on RMR system from Bieniawski. The stability calculations procedure of the rock slopes are divided into two stages. In the first stage, it is calculated for the stability of each 'global' slope without any rock support and shotcrete system. In the second stage, it is calculated for each 'local'slope stability with berms and supported with rock bolts and shotcrete. The monitoring instrumentation was performed continuously and some of the design modification was carried out in order to increase the safety of failed area based on the unforeseen geological risks during the open cut excavation.

  • PDF

Characteristics of Zooplankton Community in the Coastal Waters of Wolseong Nuclear Power Plant, East Sea of Korea (월성원자력발전소 주변 해역 동물플랑크톤의 군집 특성)

  • Kim, Mi-Hyang;Moon, Hyung-Tae;Shin, Sang-Hee;Shon, Myung-Baek;Byun, Ju-Young;Choi, Hue-Chang;Son, Min-Ho
    • Korean Journal of Environmental Biology
    • /
    • v.28 no.1
    • /
    • pp.40-48
    • /
    • 2010
  • A total of 63 taxa was identified with a mean abundance of total zooplankton ranging from 85~28,087 indiv.$m^{-3}$. Cluster and nMDS analysis showed that the study sites could be divided into two regions: North and East part of the sampling area (group A) and South part of the sampling area (group B). The number of taxa and species varied significantly among the two regions (ANOVA, p<0.05). The pattern of the spatio-temporal distribution of the zooplankton community in the coastal waters around the Wolseong Nuclear Power Plant is affected by the variations of seasonal water temperature. However, zooplankton community were no significant between the water temperature and heated discharge.

Construction of the Heat Pump System Using Thermal Effluents for Greenhouse Facilities in Jeju and Evaluation of Cooling Performance (제주 시설온실 냉난방을 위한 발전소 온배수 활용 열펌프 시스템 구축 및 냉방성능 평가)

  • Lee, Yeon-Gun;Heo, Jaehyeok;Lee, Dong-Won;Hyun, Myung-Taek
    • Journal of Energy Engineering
    • /
    • v.27 no.4
    • /
    • pp.70-79
    • /
    • 2018
  • A heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO was constructed with the capacity of 300 RT to supply cool or hot water to greenhouse facilities located 3 km from the power station. The way of transporting heat from the thermal effluent to greenhouses at a long distance was optimized, and a monitoring system to measure the water temperature and detect a leakage in a pipe conduit was also installed. This paper presents the system configuration of the constructed heat pump system for air conditioning and heating of greenhouse facilities in Jeju, and the characteristics of major components deployed in the system. The preoperational tests of the heat pump system were conducted during the summer season in 2018 for evaluation of its cooling performance. The operational stability and cooling performance of the heat pump system were confirmed by investigating the measured fluid temperature and flow rate, and COP of the heat pump in a cooling mode.

A Tracing Survey of Hot Waste Spread from Nuclear Power Station by Means of Landsat TM Images (Landsat TM 영상에 의한 원자력 발전소로부터의 온배수 확산의 추적조사)

  • 최승필;양인태
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.231-236
    • /
    • 1997
  • Observation for hot water spread has been carried out by such activites as sampling of water with ship, etc, until now It was required further to have new probe methodologies in such issues as simultaneity, great-spheric nature, and economics due to many hindering ele- ments such as spread speed of hot waste water, weather conditions, cost and expenses, scope and location determinations. However, it was believed that satellite could be utilized to monitor spread of water temperature and spread level in more quick and correct way than existing one, because it would be possible to supervise and detect marine environment within significantly short period if analyzed by means of satellite images. Therefore, this study is taken into account to flow and spread conditions of hot waste water, survey of water temperature, by means of satellite images.

  • PDF

A study on the development of drainage system for rapid drainage of thermal power plant outdoor coal storage during rainfall and characteristics of discharged water quality (강우시 화력발전소 옥외저탄장 신속한 배수를 위한 배수시스템 개발 및 배출 수질 특성에 관한 연구)

  • Lim, Chang-Min;Kwon, Hyun-Woo;Kim, Young-Min;Cho, Do-Young;Lee, Gun-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.189-190
    • /
    • 2022
  • Power plants that produce electricity through thermal power plants mainly store coal in outdoor storage yards. In particular, coal is directly exposed to rainwater during rainfall, including torrential rain. There is no separate drainage facility in the outdoor coal yard, and coal is simply stored on the ground. Accordingly, during rainfall, coal dust flows down by rainwater, and a large amount of rainwater that is not drained overflows the outdoor coal yard, overflowing the surrounding facilities and causing environmental pollution. Therefore, in this study, a drainage system was developed for the rapid drainage of an outdoor coal mine, and the quality of the water was evaluated when rainwater mixed with drainage characteristics and coal dust was discharged through the drainage system.

  • PDF

Seasonal Variation of Thermal Effluents Dispersion from Kori Nuclear Power Plant Derived from Satellite Data (위성영상을 이용한 고리원자력발전소 온배수 확산의 계절변동)

  • Ahn, Ji-Suk;Kim, Sang-Woo;Park, Myung-Hee;Hwang, Jae-Dong;Lim, Jin-Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.4
    • /
    • pp.52-68
    • /
    • 2014
  • In this study, we investigated the seasonal variation of SST(Sea Surface Temperature) and thermal effluents estimated by using Landsat-7 ETM+ around the Kori Nuclear Power Plant for 10 years(2000~2010). Also, we analyzed the direction and range of thermal effluents dispersion by the tidal current and tide. The results are as follows, First, we figured out the algorithm to estimate SST through the linear regression analysis of Landsat DN(Digital Number) and NOAA SST. And then, the SST was verified by compared with the in situ measurement and NOAA SST. The determination coefficient is 0.97 and root mean square error is $1.05{\sim}1.24^{\circ}C$. Second, the SST distribution of Landsat-7 estimated by linear regression equation showed $12{\sim}13^{\circ}C$ in winter, $13{\sim}19^{\circ}C$ in spring, and $24{\sim}29^{\circ}C$ and $16{\sim}24^{\circ}C$ in summer and fall. The difference of between SST and thermal effluents temperature is $6{\sim}8^{\circ}C$ except for the summer season. The difference of SST is up to $2^{\circ}C$ in August. There is hardly any dispersion of thermal effluents in August. When it comes to the spread range of thermal effluents, the rise range of more than $1^{\circ}C$ in the sea surface temperature showed up to 7.56km from east to west and 8.43km from north to south. The maximum spread area was $11.65km^2$. It is expected that the findings of this study will be used as the foundational data for marine environment monitoring on the area around the nuclear power plant.

Heating Performance Analysis of the Heat Pump System for Agricultural Facilities using the Waste Heat of the Thermal Power Plant as Heat Source (발전소 폐열을 이용한 농업시설용 히트펌프시스템의 난방 성능 분석)

  • Kang, Youn Koo;Kang, Suk Won;Paek, Yee;Kim, Young Hwa;Jang, Jae Kyung;Ryou, Young Sun
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.317-323
    • /
    • 2017
  • In this study, the heating performance and the energy saving effect of the heat pump system using hot waste water(waste heat) of the thermal power plant discharged from a thermal power plant to the sea were analyzed. The greenhouse area was $5,280m^2$ and scale of the heat pump system was 120 RT(Refrigeration Ton), which was divided into 30 RT, 40 RT and 50 RT. The heat pump system consisted of the roll type heat exchangers, hot waste water transfer pipes, heat pumps(30, 40, 50 RT), a heat storage tank and fan coil units. The roll type heat exchangers was made of PE(Poly Ethylene) pipes in consideration of low cost and durability against corrosion, because hot waste water(sea water) is highly corrosive. And the heating period was 5 months from October to February. During the heating performance test(12 hours), the inlet water temperature of evaporator was changed from $32^{\circ}C$ to $26^{\circ}C$, and heat absorption of he evaporator was changed from 175 kW to 120 kW. The inlet water temperature of the condenser rose linearly from $15^{\circ}C$ to $50^{\circ}C$, and the heat release of condenser was reduced by 40 kW from 200 kW to 160 kW. And the power consumption of the heat pump system increased from 30 kW to 42 kW. When the inlet water temperature of condenser was $15^{\circ}C$, the heating COP(Coefficient Of Performance) was over 7.0. When it was $30^{\circ}C$, it dropped to 5.0, and when it was above $40^{\circ}C$, it decreased to less than 4.0. It was analyzed that the reduction of heating energy cost was 87% when compared to the duty free diesel that the carbon dioxide emission reduction effect was 62% by recycling the waste heat of the thermal power plant as a heat source of the heat pump system.

Spatial and Temporal Patterns of Coralline Algae around Three Nuclear Power Plants on the East Coast of Korea (동해안 3개 원전 주변 산호말류의 시.공간적 분포양식)

  • Ahn, Jung-Kwan;Kim, Young-Hwan
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.1
    • /
    • pp.114-123
    • /
    • 2009
  • The species composition and biomass of coralline algae around three (Uljin, Wolseong and Gori) nuclear power plants on the east coast of Korea were investigated seasonally from February 1997 to October 2006. As a result, 13 species of coralline algae were found during the past ten years. Among them, Corallina pilulifera, C. officinalis, Amphiroa zonata and Pneophyllum zostericolum were common species that occurred more than 50% in frequency during the study period. Species number of coralline algae were between 10$\sim$12 species at the breakwaters near the outfalls of power plants and 8$\sim$12 species at the control area, and differences in species composition were not observed among study sites. Seasonal fluctuations of mean biomass were 0$\sim$2,530 g dry wt m$^{-2}$ and dominant species in biomass was Corallina pilulifera at all the study sites. The breakwaters of power plants generally had a greater coralline algal biomass than the control area. Biomass proportions of coralline algae at the breakwaters of power plants were also higher than those at the control area. At the Uljin sites, particularly, biomass of coralline algae showed greatest in summer and biomass proportion showed highest during the summer season. Differences in the spatio-temporal patterns of coralline algae around three nuclear power plants on the east coast of Korea were presumably due to the regional temperature variations.

Analysis of the Discharge Capacity Improvement of a Lock Gate by Using 3-Dimensional Numerical Simulation (3차원 수치모의를 이용한 배수갑문의 방류능력 개선효과 분석)

  • Kim, Nam-Il;Kim, Dae-Geun;Lee, Kil-Seong;Kim, Dal-Sun
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.3 s.152
    • /
    • pp.189-198
    • /
    • 2005
  • This study showed that numerical simulation can be effectively used to analyze discharge capacity according to the form and arrangement of the lock gate of a tidal power plant. For the numerical simulation, FLOW-3D with Reynolds-averaged Navier-Stokes equation as a governing equation was used. This study found that improvement of apron length and approach angle of guide wall of the lock gate causes differences in discharge capacity of $10\%$ or more. In addition, there was a difference of discharge capacity caused by the connecting structures of the drainage gate and hydraulic turbine structure and the side slope at the end of apron. This study also showed that hydraulic investigation to enhance a discharge capacity is needed when the lock gate is designed and that numerical model experiments can be a useful analysis tool to design the drainage structure, as well as the hydraulic model experiment.

Effects of Thermal Effluent from Nuclear Power Plant on Growth of Sea Squirt, Haiocynthia roretzi (원자력발전소 온배수에 따른 우렁쉥이의 성장)

  • Kim Seong Gil;Kwak Hi Sang;Kang Ju Chan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.71-76
    • /
    • 2002
  • To understand the effect of heated effluent from a nuclear power plant on marine organism, experimental culture of Halocynthia roretzi was carried out at heated effluent of Wolsung nuclear power plant from January to December 1996. Temperature was $11.2\~27.9^{\circ}C$ and salinity was $32.54\~34.59\%_{\circ}$ during the culture period, The Growth of H. roretzi on lower area of Bonggil-ri (St. 1) was not normal in height, breadth and weight due to heated effluent. Daily growth rate (DGR) of H. roretzi about Kampo area (St, 4) was significant other station, and St. 1 was significant from other station except St. 4, Mytilus edulis was major fouling organism (over $90\%$) that were M. edulis, Dideninum moseleyi, Styela clava in experiment culture farm. St. 1 was higher (mean 143 individual) and St. 4 was lower (mean 56 individual) appearance attached of M. edulis. Growth of H. roretzi reduced when attached number of M. eduiis was increased, because correlation between DGR and number of M. edulis was negative.