Analysis of The Problem of Exercising the Right of Claim for the Sale of the Housing Reconstruction Project (주택재건축사업의 매도청구권 행사 절차의 문제점 분석)

  • Kim, Kil-Chan;Park, Kyoung-Mi;Eom, Sun-Yong;Lee, Myeong-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.7
    • /
    • pp.508-518
    • /
    • 2011
  • In various urban renewal projects related to real estate, developer in order to conduct the business, must get real estate inside project section directly or receive the consent for project from the owners. It must be carried out by consultation. When it fails, developer, in order to get ownership, adopts 'the Right of Claim for the sale' which has forcibleness. However, because the procedure for implementation of the right of claim for the sale is not clear, conflict between stakeholders is caused and it causes extension of period. Therefore, after examining judgments and references of judicial power for administrative litigation of the Right of Claim for the sale, by researching stakeholders of the housing rebuilding project and based on the results, finding out differences of stakeholders' recognition according to their position and problems of exercising procedure of the Right of Claim for the sale, and by presenting improvement plans of the system of the Right of Claim for the sale, contributing the success of the housing rebuilding project is the purpose of it.

Cracking Behavior of RC Tension Members Reinforced with Amorphous Steel Fibers (비정질 강섬유로 보강된 철근콘크리트 인장부재의 균열거동)

  • Park, Kyoung-Woo;Lee, Jun-Seok;Kim, Woo;Kim, Dae-Joong;Lee, Gi-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.475-482
    • /
    • 2014
  • This paper presents the experimental results concentrically reinforced concrete tension members and compares cracking behavior of amorphous steel fiber and normal steel fiber reinforced concrete members. Two kind of steel fibers were included as a major experimental parameter together with the six cover thickness to bar diameter ratio ($c/d_b$). The presence of amorphous steel fibers effectively controlled the splitting cracks initation and propagation. In the amorphous steel fiber reinforced specimens, no splitting cracks were observed that becomes higher with cover thickness to bar diameter ratio is 2.0. Crack spacing of the each specimens reinforced with amorphous steel fibers and normal steel fibers becomes larger with the increase in cover thickness, and also measured maximum and average crack spacing are significantly smaller than current design code provision. Based on the measured crack spacings, a relationships for predicting the crack spacing is proposed using the measured average crack spacing in amorphous steel fiber reinforced concrete tension members.

A Study on Improvement of Fire-fighter's outfits and fire-fighting scenarios for effective water-extinguishment on ship (효과적인 선상 수소화를 위한 소방원 장구 및 화재진압 시나리오 개선에 관한 연구)

  • Sim, Hyo-Sang;Park, Young-Soo;Ha, Won-Jae
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2016.05a
    • /
    • pp.100-102
    • /
    • 2016
  • Every crew are in great peril that they should put out a fire on board in person due to a property of ship isolated. Accordingly, it is essential to verify whether the fire-fighter's outfits and fire-fighting scenarios in accordance with present regulations are safe and effective actually. As a result of comparison between shore fire-fighter's outfits and fire-fighting scenarios and those on ship and statistics calculation of the place and frequency of the fire of actual ship, present limitations of fire suppression system and fire-fighter's outfits were proved. In addition, derive the distance to the place on ship that has highest frequency of fire occurrence from examining actual ship's drawings according to their description and size. Finally from experiments in more experimental groups by changing numbers of actual fire-fighters and environment and conduction of survey of a number of crew in active service on ship, the most effective fire-fighter's outfits system and fire-fighting scenarios will be derived.

  • PDF

A Study on improvement of education training for private Security (일반경비원 교육훈련제도의 개선방안에 관한 연구)

  • Huh, Koung-Mi;Park, Young-Ju
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.529-550
    • /
    • 2007
  • In proportion to the increase of public security demand, the private companies advanced continuously every year. However the size of the industry expanded in its quantity, the quality remains the same as before. So it's important to training of the security officers. This study suggest the improvements of training system through the analysis and the review of problems of training and education security officers. To develop our private security industry, we suggest as follows. First, In spite of the training is important, the recognition against security officers training is low, so the improvement is demanded. Second, When selecting the educational institution, it does not reflect the demand and situation of education enough. So there is necessary that selecting the educational institution again, after finishing a demonstration duration. Third, The education contents is general, so there is a necessity of the education which is professionalized. Fourth, In order to improve the ability of the lecturer, we must strengthen the qualification of the lecturer. Fifth, For the development of securities industry, we must found the professional training institution.

  • PDF

Evaluation of Privately Owned Public Spaces within Detached Housing Areas in Pangyo City - Focusing on the Mixed use Housing Areas (가구내부 공유외부공지의 조성실태에 관한 연구 - 서판교 점포주택지를 중심으로)

  • Park, Kyung Seo;Kang, Jun Mo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.157-167
    • /
    • 2016
  • Detached residential housing areas are located in the west part of Pangyo City. Seven areas of them are designated for the displaced residents from their original homes by the city development, in which commercial use on the first floor is permitted. The District Plan for the areas were establishes, and one of its main goals is to secure privately owned public spaces (POPS). This research conducted a post enumeration survey on the POPS on the blocks in the seven areas, which blocks contain inner corridors between two rows of housing units. Analytical review of the survey result reveals that (1) POPS facing roads are mainly being used as parking lots or expansion-spaces for the commercial use on the first floor, (2) inner POPS forming corridors are being neglected and otherwise being used as storage areas or outdoor sub-kitchen spaces, and (3) no consideration has been taken for the continuity of the sloped corridors. Regardless of a few good practices in terms of air circulation and lighting, the POPS in the blocks prove to be limited in following the plan's original design intentions and principles.

Micro-Hydropower System with a Semi-Kaplan Turbine for Sewage Treatment Plant Application: Kiheung Respia Case Study (하수처리장 적용을 위한 Semi-카플란 수차가 장착된 마이크로수력발전 시스템: 기흥레스피아 사례)

  • Chae, Kyu-Jung;Kim, Dong-Soo;Cheon, Kyung-Ho;Kim, Won-Kyoung;Kim, Jung-Yeon;Lee, Chul-Hyung;Park, Wan-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.363-370
    • /
    • 2013
  • Small scale hydropower is one of most attractive and cost-effective energy technologies for installation within sewage treatment plants. This study was conducted to evaluate the potential of a semi-kaplan micro-hydropower (MHP) system for application to sewage treatment plants with high flow fluctuations and a low head. The semi-kaplan MHP is equipped with an adjustable runner blade, and is without a guide vane, so as to reduce the incidence of mechanical problems. A MHP rating 13.4 kWp with a semi-kaplan turbine has been considered for Kiheung Respia sewage treatment plant, and this installation is estimated to generate 86.8 MWh of electricity annually, which is enough to supply electricity to over 25 households, and equivalent to an annual reduction of 49 ton $CO_2$. The semi-kaplan turbine showed a 90.2% energy conversion efficiency at the design flow rate of 0.35 $m^3/s$ and net head of 4.7 m, and was adaptable to a wide range of flow fluctuations. Through the MHP operation, approximately 2.1% of total electricity demand of Kiheung Respia sewage treatment plant will be achievable. Based on financial analysis, an exploiting MHP is considered economically acceptable with an internal rate of return of 6.1%, net present value of 15,539,000 Korean Won, benefit-cost ratio of 1.08, and payback year of 15.5, respectively, if initial investment cost is 200,000,000 Korean Won.

Manufacturing Digital Map Version 2.0 Increased Visual Information (시각적 정보력이 향상된 수치지도 Ver. 2.0제작)

  • Park Kyeong Sik;Lee Jae Kee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.3
    • /
    • pp.221-231
    • /
    • 2005
  • Though Digital Map Ver. 2.0 is adequate to GIS, the possibility to gain information from its external form and the ease of producing paper map had retrogressed. In this research, concerned with the problems, we plan to make Digital Map Ver. 2.0, which satisfies the conditions of GIS. It will have geometrical and logical data structure, and also possess informative ability as much as that of Ver. 1.0. For the study, the process to analyze the topographic code, color, code priority order, etc. of paper relief map, digital map Ver. 1.0, and digital map Ver. 2.0 was taken. For the topographical feature with diverse expression, we changed the portrayal of digital map Ver. 2.0 to make it fit the regulations of map portrayal. At the point of topographic code priority order, the rule is to arrange them in the same order as the real territory. However, we made a special code in the case of any change of the locational order. According to the property of this study, we observe the regulations of map portrayal, for the elements related to subjective sense, such as colors. And we give priority on the data construction when the portrayal of topographical feature and the schema of GIS database system are contradictory.

A Study on the Improvement of Legal System for the Prevention of Damage due to Ash (화산재해로 인한 항공교통분야 피해예방을 위한 법규체계 개선방안에 대한 연구)

  • Lee, Young-Sub;Lee, Young-Kune;Park, Miri
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.277-283
    • /
    • 2017
  • In recent years, earthquakes and volcanic activity have been occurring actively in Japan, China, and Southeast Asia in the central Pacific Rim, and the cycle interval is shortening. In addition, there is Baekdu mountain, which is a large active volcano in Korea. On the other hand, the legal system and guidelines related to volcanic ash are very limited to counteract volcanic disasters. The volcano manual does not present specific countermeasures against volcanic disasters. The preparation of systematic disaster prevention measures against an eruption of Mt. Baekdu and the volcanic activity in Japan and China, which are occurring continuously, is necessary. Therefore, this study suggests an improvement to the relevant laws and regulations against volcanic disasters to analyze the aviation safety manual and relevant legal system. The problems with the current legal system are improved by modifying the legal system related to the air traffic sector when volcanic disaster occurs, and it is expected that more efficient manuals and guidelines will form the basis for the smooth operation of the manual at a disaster site.

A Study on the Educational Efficacy of a Maritime English Learning and Testing Platform (해사영어학습 및 평가 플랫폼을 활용한 교육 효과에 대한 연구)

  • Seor, Jin Ki;Park, Young-soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.4
    • /
    • pp.374-381
    • /
    • 2020
  • According to international regulations, it is mandatory for navigators or engineers to acquire suitable skillsets before their designation as a duty officer on board. One of the most important elements is Maritime English (ME), wherein students are taught a required set of basic skills that enable them to process various documents related to accidents, ship conditions, and inspections. Students have to be equipped not only with the use of general English skills but also with the coherent use of technical terms and phrases. However, due to the unique circumstances that exist in the maritime domain, the methods used for imparting maritime knowledge and the manner in which it is evaluated are restricted. Hence, this study aims to utilize an online Maritime English learning and testing platform that can be accessed on smart devices to analyze its impact on the students' learning process. An experiment was conducted on two groups of cadets, one that used the platform and another group that did not. After six-week, the experiment results showed a significant difference between the ME test scores of the two groups. The test scores were further analyzed by incorporating the students' personal elements to measure the ef icacy of the ME test platform. Therefore, the learning and evaluation processes are expected to be implemented in ways that are appropriate and convenient to specific circumstances and be widely used in the field of maritime education in the future.

A Study on the Optical Internal Recycle Rate and MLSS Concentration of Membrane Coupled $A_2O$ Process for Wastewater Treatment (하수처리를 위한 막결합형 $A_2O$공정에서 최적 내부 순환율 및 MLSS 농도에 관한 연구)

  • Kim Kwan-Yeop;Kim Jin-Mo;Kim Hyung-Soo;Lee Sang-Bek;Park Eugene;Bae Sung-Soo
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.114-120
    • /
    • 2005
  • The purpose of this study is to obtain practical information about membrane coupled $ A_2O$ system for muncipal wastewater treatment. A flat-plate microfiltration (MF) module with a pore size $0.25\;{\mu}m$ was submerged into the aeration basin and treated water was filtrated through the membrane by continuous suction with low pressure. The system was operated with synthetic wastewater to find operational parameters of internal recycle ratio and maximum MLSS showing best water quality and long-term stability. The internal recycle was defined as type 1 for aerobic to anoxic tank and type 2 for anoxic to anaerobic tank, respectively When the flux was maintained at $0.015\;m^3/m^2/hr$ (15 LMH) with 2Q type 1 internal recycle ratio, the optimal operational setting were 10 internal recycle ratio for type 2 and maximum MLSS of 11,000 mg/L among tested conditions. At this condition, removal efficiencies of BOD, CODcr, T-N and T-P showed $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$, respectively.