• Title/Summary/Keyword: 바이오 임피던스 분석

Search Result 20, Processing Time 0.026 seconds

Analysis on Upper Extremity of Hemiplegic Stroke Patients Using Bioelectrical Impedance (바이오 임피던스 분석을 이용한 뇌졸중 편마비환자의 상지 분석)

  • Yoo, Chan-Uk;Park, Ju-Hyung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.10
    • /
    • pp.94-101
    • /
    • 2017
  • This study is to compare and analyze the bioelectrical impedance values on the upper extremity (affected and non-affected side) in hemiplegic stroke patients. Experimental subjects were 24 stroke patients with hemiplegia undergoing stroke rehabilitation between October to November, 2015. Prediction marker, resistance, reactance, and phase angle were measured in the upper extremity (affected and non-affected side) of hemiplegic stroke patients, using MultiScan 5000, and then they were expressed as quantified values. The affected and non-affected side of upper extremity in stroke patients with hemiplegia exhibited significant differences in prediction marker, reactance, and phase angle (p<0.05). There were significant differences in the impedance values at the affected and non-affected side of hemiplegic stroke patients. Thus, the possibility of evaluating stroke patients undergoing clinical rehabilitation therapy was suggested.

실시간 고감도 온도 및 임피던스 측정 바이오센서 제작

  • Im, Gyeong-Seok;Sin, Hye-Seon;Jang, Mun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.343-343
    • /
    • 2016
  • 최근 사회적 이슈로 동물실험에 대한 규제가 강화되고 있어 동물실험을 대체할 새로운 방안의 중요성이 부각되고 있다. 이에 따라 현재 동물실험의 대체 방안의 하나로 3D 프린팅 기술을 활용한 3차원으로 배양된 인공장기에 대한 연구가 활발히 진행 중이다. 하지만 실시간으로 세포의 변화를 모니터링 할 수 있는 기술에 대한 연구는 많이 이루어지지 않고 있다. 본 연구에서는 3차원으로 배양된 세포에서 약물반응에 따른 세포변화를 실시간으로 분석할 수 있는 고감도 온도 및 임피던스 측정 바이오센서를 제작하였다. 센서 제작에 앞서 바이오센서로 사용하기 위해서는 세포를 안정적으로 성장시킬 수 있는 물질을 사용해야하며, 반도체공정으로 박막증착이 쉽고 물질변화가 크지 않도록 높은 work function(백금의 work function : 5.12~5.93 eV)을 가져야한다. 또한 온도 및 임피던스 측정을 위해 지표로 사용할 수 있는 TCR(Temperature Coefficient of Resistance)값이 온도에 따라 선형적으로 증가하는 특성을 가져야 한다. 위 조건들을 고려하여 센서물질로 백금을 선정하였다. 박막공정 및 열처리를 통하여 추출된 백금의 TCR은 $2045.9ppm/^{\circ}C$의 값을 가졌고, 추출된 백금의 TCR과 관계된 온도센서의 오차범위는 $0.01^{\circ}C$내에 있다. 이는 실시간으로 세포 변화를 분석할 수 있는 지표로써 활용되며, 고감도의 온도센서로써의 역할을 하기에 충분한 값이다.

  • PDF

Study on the characteristic Impedance of Biconical antenna Consisting of 4m conical wires (다소선 Biconical antenna 특성 임피던스)

  • 박정기;이두수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.2
    • /
    • pp.27-32
    • /
    • 1974
  • The characteristic impedance of a biconical antenna which is the conical cage consisting of 4m conical wires is obtained analytically under some assumption. The effect of the number of the elements on the characteristic impedance is observed according to the equation of the characteristic impedance derived in this paper. The equation is not convenient for practical use. However, a compact form of the equation is obtained by assuming that the apexangle is not very large. The numerical solution of this approximate equation is found to show errors no more than 2% over a wide range of the apex angle .

  • PDF

Electrochemical Impedance Spectroscopy (EIS) study of the Corrosion Resistance of Zn-Mg coatings with 6.72wt.% Mg contents (6.72wt.% Mg 함량을 갖는 Zn-Mg 박막의 침지 시간에 따른 전기화학적 임피던스 분광법 (EIS) 연구)

  • Bae, Gi-Tae;Ra, Jeong-Hyeon;Lee, Sang-Yul
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.05a
    • /
    • pp.174-174
    • /
    • 2015
  • 아연 도금 강판은 우수한 내식성으로 인해 널리 사용되고 있지만 최근 아연의 자원 고갈 및 지속적인 가격 상승문제로 인해 아연의 사용량을 줄이기 위한 연구 들이 진행 중이다. 최근 마그네슘이 첨가 된 아연 박막이 기존 아연 도금 강판에 비해 우수한 내식성을 갖는 결과들이 보고 된 바 있다. 본 연구에서는 비대칭 마그네트론 스퍼터링 방식을 활용해 합성된 Zn-Mg 박막을 전기화학적 임피던스 분광법 (EIS)을 통해 침지시간에 따른 전하이동저항의 변화를 분석하였다. EIS와 XRD 분석 결과에서 Zn-Mg 박막이 부식되면서 형성되는 안정한 simonkolleite 상이 전하이동저항의 증가에 큰 영향을 미치는 것으로 판단된다.

  • PDF

Analysis of Lower Leg Movement Using Bio-impedance Technique (바이오 임피던스를 이용한 하지 운동분석)

  • Song, C.G.;Song, C.H.;Lee, M.G.;Kim, S.C.;Kim, J.C.;Seo, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.414-417
    • /
    • 2002
  • This paper describes the possibility of analyzing gait pattern from the variation of the lower leg electrical impedance. This impedance is measured by the four-electrode method. Two current electrodes are applied to the thigh and foot., and two potential electrodes are applied to the lateral aspect, medial aspect, and posterior position of lower leg. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. From such features of the lower leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level.

  • PDF

바이오센서 응용을 위한 그래핀 전극 표면의 결함준위에 따른 전기화학적 특성 분석

  • Park, Min-Jeong;Hwang, Suk-Hyeon;Im, Gi-Hong;Choe, Hyeon-Gwang;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.386.2-386.2
    • /
    • 2014
  • 본 연구에서는 바이오 센서 응용을 위해 그래핀을 전극으로 제작하여 그래핀 표면 결함준위에 따른 센서의 민감도를 전기화학 실험을 통해 관찰하였다. 그래핀은 니켈/구리촉매를 이용한 저 진공 화학 기상 증착 장비(Low-Pressure Chemical Vapor Deposition; LP-CVD)와 Photo-lithography로 제작한 것과 탄소 산화물을 환원시켜 만든 환원-그래핀, 두 가지를 사용하였다. 전기화학 실험에서 그래핀 전극 및 Silver/Silver chloride (Ag/AgCl), Fluorine doped Tin Oxide (FTO)은 작업 전극 및 기준 전극, 상대 전극으로 각각 사용하였고, 반응용액은 potassium hexacyanoferrate (III)를 농도를 다르게 하여 사용하였다. 그래핀의 표면 상태, 층수, 결함 정도 등 구조적인 특성은 원자력현미경(Atomic Force Microscopy; AFM), 주사 전자 현미경(Secondary Electron Microscopy; SEM)과 Raman spectroscopy를 각각 이용하여 확인하였고, 그래핀의 결함준위에 따른 반응면적 및 센서 감도 의존성을 전류모드-원자력현미경(Current-Atomic Force Microscopy; I-AFM)과 전기화학 임피던스 분광법(Electrochemical Impedance Spectroscopy; EIS)를 통해 그래핀 전극의 성능을 분석하고, 그래핀 결함 준위에 따른 센서 감도 의존성은 순환전위 분광법 (Cyclic Voltammetry; CV)를 이용하여 관찰하였다. 또한 농도가 다른 반응용액은 센서의 민감도를 관찰하는데 사용하였다. 결과적으로 LP-CVD로 성장한 그래핀과 환원-그래핀의 결함준위에 따른 센서의 성능을 비교 분석한 결과와 반응용액 농도에 따른 센서의 민감도 결과는 그래핀 바이오센서에 대한 응용 및 상용화를 앞당기는데 기여할 것으로 예상한다.

  • PDF

Signal Characteristics of Multi-coil Probe for the Test of Reinforcement Embedded in Concrete (다중 코일에 의한 콘크리트내의 철근 탐지 시 신호 특성)

  • Kim, Young-Joo;Lee, Seung-Seok;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.285-289
    • /
    • 2000
  • This study suggests a rebar detection technique for simultaneous detection of size and cover of embedded reinforcement in concrete. The structure of the probe made in this study is somewhat different from commercial ones. This probe has three sensing coils. Rebar size and cover depth can be evaluated by detecting and analyzing the signal from them. Amplitude and phase variation of each coil in the probe was investigated using an impedance analyzer and the loci of transfer functions of the coils were analyzed. The locus of transfer function from the sensing coil positioned inside excitation coil was simple as well known, but the others from the coils outside excitation coil were not so. Actual experiment on rebar detection was performed with our probe and an eddy current test system for various rebar sizes and depths. The signal shape according to variation of cover depths showed the same tendency with the transfer function loci acquired by impedance analyzer. The different variation pattern of signal enabled to evaluate rebar size and cover depth simultaneously.

  • PDF

Study for analyzing decisive factors on short circuits of testing laboratory with short circuit generator using super excitation(I) (발전기 과여자를 고려한 단락시험회로의 회로특성 결정인자 분석연구(I))

  • Ahn, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.7-9
    • /
    • 2003
  • 전력계통의 정상상태와 다양한 초장상태를 모의하기위한 단락시험설비는 크게 단락발전기, 보호차단기, 전류제한 리액터, 투입스위치, 단락변압기, 버스바 및 케이블, 투입피크 제한장치, 부하회로 및 측정장치 등으로 구성되어 있으며, 유효한 시험을 위해서는 이러한(변수)조합들을 적절하게 조절, 제어하여 실계통의 현상을 재현하거나 규격 또는 의뢰자의 요구에 부응하도록 하는 것이 중요하다. 이것을 위해서는 각 시험설비의 정상 및 과도 특성과 조합된 회로에 상존하는 변수(stray values)들을 찾아내고, 이들에 대한 독립성과 의존성 관계를 파악하여 계산 가능한 모델링을 도출 하여야 한다. 그러나 경험적으로 볼때 단락발전기의 과도임피던스 및 여자 특성과 변압기를 포함한 회로상의 stray values 등이 여러 변수들과 만들어내는 상관관계를 파악하는데는 좀 어려움이 있었다. 본 논문에서는 이러한 관점에서 상기 변수에 따른 변화 기여도를 가능한 한 정량적으로 분석하여 회복전압, TRV 및 전류와의 상관관계를 규명해 보고자 한다.

  • PDF

A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method (전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구)

  • Han, Kyoung Ho;Shin, In Seong;Yoon, Do-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, the development of biosensors capable of bi-enzyme reactions by including Horseradish peroxidase and glucose oxidase was carried out for detection of glucose. The sensors were manufactured using electro deposition method to reduce production time, and screen printed electrodes (SPE) were used to produce economical sensors. To check the bienzyme effect, the sensor was compared and analyzed with single enzyme biosensor. The characteristics of the sensor were evaluated using scanning electron microscopy(SEM), cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS), chronoamperometry(CA), and flow injection analysis(FIA). Analysis results from SEM, CV and EIS confirmed that the enzymes are well fixed to the electrode surface. In addition, it was confirmed that bi-enzyme biosensors manufactured from the CA method improved signal performance by 200% compared to single enzyme biosensors. From this results, we were able to explain that HRP and GOD react catalyzed to each other. And the results of FIA showed that the intensity of each current signal was constant when the same concentration of glucose was injected four times. In addition, by analyzing the intensity of current signals for glucose concentrations, the biosensors manufactured in this study showed excellent trends in signal sensitivity, reproducibility and stability.

A Study on the Electrochemical Characteristics of Biosensor with HRP Enzyme Immobilized on SPCE (SPCE에 HRP 효소가 고정화된 바이오센서의 전기화학적 특성에 관한 연구)

  • Han, Kyoung Ho;Lee, Dae Hyun;Yoon, Do Young;Choi, Sangil
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.3
    • /
    • pp.73-80
    • /
    • 2020
  • Fenton oxidation method using hydrogen peroxide is an eco-friendly oxidation method used in water treatment and soil restoration. When removing pollutants by this method, it is quite important to properly regulate the concentration of hydrogen peroxide according to the concentration of the contaminants. In this study, electrochemical biosensors using HRP (horseradish peroxidase) enzymes were manufactured and studies were conducted on the activity of enzymes and the detection characteristics of hydrogen peroxide. HRP were electro deposited with chitosan and AuNP on the working electrode surface of the SPCE (Screen Printed Carbon Electrode). Then, the fixation of enzymes was confirmed using the cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The activity of HRP enzymes was also identified from chronoamperometry (CA) and UV spectroscopy. After immersing the biosensor in PBS solution the current generated from electrodes by titrating hydrogen peroxide was measured from CA analysis. The generated current increased linearly for the concentration of hydrogen peroxide, and a calibration curve was derived that could predict the concentration of hydrogen peroxide from the current.