DOI QR코드

DOI QR Code

A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method

전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구

  • Han, Kyoung Ho (Department of Chemical Engineering, Kwangwoon University) ;
  • Shin, In Seong (G&G InTech Co. Ltd., Central R&D Center) ;
  • Yoon, Do-Young (Department of Chemical Engineering, Kwangwoon University)
  • 한경호 (광운대학교 공과대학 화학공학과) ;
  • 신인성 (지앤지인텍 중앙연구개발센터) ;
  • 윤도영 (광운대학교 공과대학 화학공학과)
  • Received : 2020.04.22
  • Accepted : 2020.06.12
  • Published : 2020.08.31

Abstract

In this study, the development of biosensors capable of bi-enzyme reactions by including Horseradish peroxidase and glucose oxidase was carried out for detection of glucose. The sensors were manufactured using electro deposition method to reduce production time, and screen printed electrodes (SPE) were used to produce economical sensors. To check the bienzyme effect, the sensor was compared and analyzed with single enzyme biosensor. The characteristics of the sensor were evaluated using scanning electron microscopy(SEM), cyclic voltammetry(CV), electrochemical impedance spectroscopy(EIS), chronoamperometry(CA), and flow injection analysis(FIA). Analysis results from SEM, CV and EIS confirmed that the enzymes are well fixed to the electrode surface. In addition, it was confirmed that bi-enzyme biosensors manufactured from the CA method improved signal performance by 200% compared to single enzyme biosensors. From this results, we were able to explain that HRP and GOD react catalyzed to each other. And the results of FIA showed that the intensity of each current signal was constant when the same concentration of glucose was injected four times. In addition, by analyzing the intensity of current signals for glucose concentrations, the biosensors manufactured in this study showed excellent trends in signal sensitivity, reproducibility and stability.

본 연구에서는 글루코스 검출을 위한 HRP (horseradish peroxidase)와 GOD (glucose oxidase)를 혼합한 형태의 다중 효소 반응 바이오센서 개발연구를 수행하였다. 바이오센서는 제작 시간 단축을 위하여 전기전착법을 이용하여 제작하였으며, 경제적인 센서 제작을 위하여 SPE (screen printed electrode)를 사용하였다. 다중 효소 바이오센서의 효과를 확인하기 위하여 단일 효소 바이오센서를 제작하여 비교 및 분석하였다. 센서의 특성을 평가하기 위해서 주사전자현미경(scanning electron microscopy, SEM), 순환전위법(cyclic voltammetry, CV), 전기화학적 임피던스 분광법(electrochemical impedance spectroscopy, EIS), 시간대전류법(chronoamperometry, CA), 흐름 주입분석법(flow injection analysis, FIA)를 수행하였다. SEM, CV, EIS의 분석결과로부터 효소가 전극 표면에 고정화가 잘 된 것을 확인하였고, CA로부터 제작된 다중 효소 바이오센서가 단일 효소 바이오센서에 비해 신호성능이 200% 향상된 것을 확인하였다. 이로부터 HRP와 GOD가 서로 촉매적으로 반응한다는 것을 설명할 수 있었다. 또한, FIA의 결과에서 동일한 농도의 글루코스 용액을 4회 나누어 주입하였을 때, 전류신호량이 일정함을 확인하였고, 농도에 따른 전류신호량을 분석하여 신호민감성, 재현성, 안정성 등이 우수함을 설명할 수 있었다.

Keywords

References

  1. X. Luo, J. Xu, Y. Du, H. Chen, 'A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition', Analytical Biochemistry, 334, 284 (2004). https://doi.org/10.1016/j.ab.2004.07.005
  2. B.W Park, D.S. Kim, and D.Y. Yoon, 'Surface modification of goldelectrode with gold nanoparticles and mixed self-assembled monolayers for enzyme biosensors', Korean J. Chem. Eng, 28, 64 (2011). https://doi.org/10.1007/s11814-010-0349-6
  3. C.X. Lei, S.Q. Hu, G.L. Shen, R.Q. Yu, 'Immobilization of horseradish peroxidase to a nano-Au monolayer modified chitosan-entrapped carbon paste electrode for the detection of hydrogen peroxide', Talanta, 59, 981 (2003). https://doi.org/10.1016/S0039-9140(02)00641-0
  4. X. Kang, J. Wang, H. Wu, I. A. Aksay, J. Liu, Y. Lin, 'Glucose Oxidase-graphene-chitosan modified electrode for direct electrochemistry and glucose sensing', Biosensors and Bioelectronics, 25, 901 (2009). https://doi.org/10.1016/j.bios.2009.09.004
  5. S. Yang, Z. Lu, S. Luo, C. Liu, Y. Tang, 'Direct electrodeposition of a biocomposite consisting of reduced graphen oxide, chitosan and glucose oxidase on a glassy carbon electrode for direct sensing of glucose', Microchim Acta, 180, 127 (2013). https://doi.org/10.1007/s00604-012-0911-5
  6. H.S. Wang, Q.X. Pan and G.X. Wang, 'A biosensor based on immobilization of horseradish peroxidase in chitosan matrix cross-linked with glyoxal for amperometric determination of hydrogen peroxide', Sensors, 5, 266 (2005). https://doi.org/10.3390/s5040266
  7. S. Chairam, P. Buddhalee and M. Amatatongchai, 'A novel hydrogen peroxide biosensor based on horseradish peoidase immobilized on poly(aniline-co-o-aminobenzoic acid) modified glassy carbon electrode coated with chitosan film', Int. J. Electrochem. Sci, 8, 10250 (2013).
  8. L. Wang, E. Wang, 'A novel hydrogen peroxide sensor based on horseradish peroxidase immobilized on colloidal Au modified ITO electrode', Electrochemistry communications, 6, 225 (2004). https://doi.org/10.1016/j.elecom.2003.12.004
  9. M. A. Sirvent, A. Merkoci, S. Alegret, 'Configurations used in the design of screen-printed enzymatic biosensors. A review', Sensors and Actuators B, 69, 153 (2000). https://doi.org/10.1016/S0925-4005(00)00536-0
  10. K. Grennan, A. J. Killard, and M. R. Smyth, 'Physical characterizations of a screen-printed for use in an amperometric biosensor system', Electroanalysis, 13, 745 (2001). https://doi.org/10.1002/1521-4109(200105)13:8/9<745::AID-ELAN745>3.0.CO;2-B
  11. S. Andreescu, L. Barthelmebs, J. Marty, 'Immobilization of acetylcholinesterase on screen-printed electrodes:comparative study between three immobilization methods and applications to the detection of organophosphorus insecticides', Analytica Chimica Acta, 464, 171 (2002). https://doi.org/10.1016/S0003-2670(02)00518-4
  12. M. P. O'Halloran, M. Pravda, G. G. Guilbault, 'Prussian Blue bulk modified screen-printed electrodes for $H_2O_2$ detection and for biosensors', Talanta, 55, 605 (2001). https://doi.org/10.1016/S0039-9140(01)00469-6
  13. F. Li, Z. Wang, W. Chen, S. Zhang, 'A simple strategy for one-step construction of bienzyme biosensor by insitu formation of biocomposite film through electrodeposition', Biosensors and Bioelectronics, 24, 3030 (2009). https://doi.org/10.1016/j.bios.2009.03.017
  14. P. Yang, L. Wang, Q. Wu, Z. Chen, X. Lin, 'A method for determination of glucose by an amperometric bienzyme biosensor based on silver nanocubes modified Au electrode', Sensors and Actuators B, 194, 71 (2014). https://doi.org/10.1016/j.snb.2013.12.074
  15. X. Chen, J. Zhu, Z. Chen, C. Xu, Y. Wang, C. Yao, 'A novel bienzyme glucose biosensor based on three-layer Au-Fe3O4@SiO2 magnetic nanocomposite', Sensors and Actuators B, 159, 220 (2011). https://doi.org/10.1016/j.snb.2011.06.076
  16. M. Gu, J. Wang, Y. Tu, J. Di, 'Fabrication of reagentless glucose biosensors: A comparison of mono-enzyme GOD and bienzyme GOD-HRP systems', Sensors and Actuators B, 148, 486 (2010). https://doi.org/10.1016/j.snb.2010.05.057