• Title/Summary/Keyword: 바닥

Search Result 3,358, Processing Time 0.029 seconds

Research on simple measurement method of floor finishing materials to predict lightweight floor impact noise reduction performance in apartment houses (공동주택 경량 바닥충격음 저감성능 예측을 위한 바닥마감재 간이측정 방법 연구)

  • Min-Woo Kang;Yang-Ki Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.594-602
    • /
    • 2023
  • To date, research on heavy floor impact noise has mainly been conducted. The reason is that in the case of lightweight floor impact noise, sufficient performance could be secured with only the floating floor structure and floor finishing materials. In the case of heavy floor impact noise in a floating floor structure, the reduction performance can be predicted to some extent by measuring the dynamic elasticity of the floor cushioning material. However, with the recent introduction of the post-measurement system, various floor structures are being developed. In particular, many non-floating floor structures that do not use cushioning materials are being developed. In floor structures where cushioning materials are not used, the finishing material will have a significant impact on lightweight floor impact noise. However, research on floor finishing materials is currently lacking. In this study, as a basic research on the development of various floor finishing materials for effective reduction of lightweight floor impact noise, various materials used as floor finishing materials for apartment complexes were selected, the sound insulation performance of lightweight floor impact noise was measured in an actual laboratory, and vibration characteristics were identified through simple experiments. The purpose was to confirm the predictability of light floor impact noise.

Existing RC deck and Simplified Composite Deck Comparative Analysis Of Punching Shear Strength (기존 RC 바닥판과 초간편 강합성 바닥판의 펀칭전단강도에 대한 비교 분석)

  • Lee, Sung-Yul;Yoon, Ki-Ying;Yi, Gyu-Sei;Kim, Sang-Seup
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.33-36
    • /
    • 2009
  • 현행 도로교설계기준의 바닥판에 대한 설계방법은 휨 이론에 따라 바닥판을 단위 폭의 보로 보고 강도설계법으로 설계하고 있다. 그러나 실제 교량 바닥판의 파괴 형태는 펀칭에 의한 파괴이므로 바닥판의 극한성능은 펀칭전단강도를 토대로 평가해야 할 것이다. 하지만 기존에 연구된 결과로는 초간편 강합성 바닥판의 펀칭전단강도를 산정하기 어려워 이에 대한 연구가 필요한 실정이다. 본 연구에서는 개발된 초간편 강합성 바닥판의 펀칭전단성능을 파악하기 위하여 초간편 강합성 바닥판과 RC바닥판에 대한 펀칭전단실험을 실시하여 비교하여 보았다.

  • PDF

Improvement of Direct Measurement of Bottom Shear Stress Using Shear Plate (전단평판을 이용한 바닥전단응력의 직접 측정 방법의 개선)

  • Jung, Dong Gyu;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.70-70
    • /
    • 2016
  • 하천시설물 설계, 시공 및 관리에 있어서 바닥전단응력은 매우 중요하다. 예를 들어, 호안 등 시설물의 허용 소류력을 계산하거나, 하천의 유사량을 예측하는 데 있어서 바닥전단응력이 기준으로 쓰인다. 정상 등류의 경우, 수로 내 수체에 작용하는 중력과 수로 바닥 및 측면에 작용하는 마찰력의 평형을 고려함으로써 바닥전단응력을 산정할 수 있다. 본 연구에서는 식생을 제외한 아크릴수로에서의 전단판의 움직임을 이용한 바닥전단응력 측정장치를 설계, 교정 및 검증을 실시하였다. 이 전단판은 수체와 바닥면에서 발생하는 마찰력에 의해 변위가 발생하고 이 변위를 바닥전단 응력으로 산정하였다. 직접 측정한 바닥전단응력은 기존에 연구된 두 가지 방법과 비교하여 검증하였다. 비교 검증을 위한 실험은 폭 0.3 m, 길이 10 m인 고속수로에서 Froude수 1이상, Reynolds수 20000이상의 사류이면서 난류인 상태로 실험을 진행하였으며 유속은 PIV을 이용하여 측정하였다. 비교 검증을 위한 첫 번째방법은 Reach-avrage공식을 기초로 manning의 평균 유속 공식을 이용한 바닥전단응력을 산정하는 방법으로 일반적으로 간단한 경험식을 이용하여 바닥 전단응력을 산정하는 방법이다, 두 번째는 Reynolds stress를 산정하는 방법으로 PIV를 통해 흐름방향의 연직프로파일의 유속을 측정 한 후 레이놀즈 분해법에 의해 산정된 난류 강도를 측정하여 Reynolds stress를 산정한 후 Shear stress를 산정하는 방법을 사용하였다. 마지막으로 본 연구에서 가로 0.14 m, 세로 0.14 m의 전단판으로 구성된 바닥전단응력 측정장치를 개발하여 실험을 진행하면서 앞에서 언급한 두가지 방법을 측정하는 동시에 장치를 이용하여 바닥전단응력을 직접측정하여 총 3가지 바닥전단응력을 비교하였다.

  • PDF

실내공기질 향상을 위한 환경친화형 바닥공조시스템

  • 조동우
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.32-40
    • /
    • 2004
  • 바닥공조시스템(underfloor air distribution system)은 건물 내에서 공기흐름을 바닥을 통해 조절하는 방식으로 전통적인 천장공조 방식을 대체할 새로운 시스템으로 평가받고 있다. 일반적으로 바닥 공조시스템은 공조기 등에서 송풍되는 공조공기가 억세스 플로어 하부의 바닥공간으로 전달되고 바닥급기구를 통해 실내로 송풍되는 구조를 이루고 있다. 바닥공조시스템의 이점은 전통적인 천장공조 방식에 비해 실내공기의 질(IAQ)이 향상되며 에너지의 절감이 가능하다는 점을 들 수 있다. (중략)

  • PDF

A Study on Bond Properties of Joint Grouting Materials for Precast Concrete Bridge Decks (프리캐스트 콘크리트 교량바닥판 이음부 채움재의 부착특성연구)

  • 김영진;정철헌;심창수
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.153-159
    • /
    • 1998
  • 최근 교통량의 증가에 의해 직접 하중을 부담하는 교량바닥판의 손상이 심각한문제로 부각되고 있다. 더욱이 차량하중의 증가는 바닥판손상을 더욱 가속화시키고 있는 실정이다. 바닥판의 손상이 심한 경우에는 교체 또는 성능개선공사를 시행하게 되는데, 이때 기존의 현장타설바닥판이 갖는 단점을 보완할 수 있는 프리캐스트 콘크리트 바닥판은 공기단축, 품질확보 등의 측면에서 매우 효과적인 대체공법이 될 수 있다. 프리캐스트 콘크리트 바닥판은 기존의 현장타설바닥판과달리 바닥판간에 이음부를 갖는 구조적 특징이 있으며, 다양한응력상태에 있는 바닥판중에 존재하는 비연속부인 이음부와 콘크리트 부재사이의 원활한 하중전달을 위해 부착강도는 매우 중요하다. 따라서 본 연구에서는 이음부의 부착강도를 함리적으로 평가할 수 있는 새로운 실험방법을 제안하고 이를 이용하여 휨, 직접인장 및 전단실험을 수행하였다. 또한 구성재료에 대한 압축, 휨인장 및 할렬인장강도 특성도 평가하였 다. 부착 및 강도특성에 관한 실험결과, 제안된 실험방법을 이용하면 실제에 근접한 부착강도를 평가할 수 있으며 국내에서 사용되는 충전재료중 무수축모르터가 프리캐스트 콘크리트 바닥판간 이음부의 채움재로서의 기본요건을 만족하고 있는 것을 알 수 있었다.

An Experimental Study on Punching Shear of Simplified Composite Deck (초간편 강합성 바닥판의 펀칭 전단에 관한 실험적 연구)

  • Yoon, Ki-Yong;Lee, Sung-Yol;Yi, Gyu-Sei;Kim, Sang-Seup
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.5
    • /
    • pp.23-30
    • /
    • 2009
  • According to Korea Highway Bridge Design Code the bridge deck is designed by the strength design method and is regarded as a beam possessing the unit width based on the bending theory. By many researches it is revealed that the existing bridge deck is failed by punching shear. For evaluating the ultimate capacity of bridge deck it is important to estimate the behavior of bridge deck under the punching shear. For the punching strength it is difficult that the existing research results are applied to the simplified composite deck. In this study for comparing characteristics on punching shear the punching shear tests on simplified composite deck and RC deck are performed. The punching shear strength of simplified composite deck is compared with several bridge design codes.

Numerical Simulation for Winnowing Failure of Bed Protection (바닥보호공의 흡출 파괴에 대한 수치모의)

  • Ha, Sung Won;Kim, Tae Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.308-308
    • /
    • 2017
  • 국내 하천에 설치된 횡단구조물은 2009년을 기준으로 약 20,753개로 알려져 있으며 수위 유지, 하상고 유지 등의 목적을 가지고 설치된다. 그러나 낙차를 가진 빠른 유속의 흐름을 형성시켜, 하류 하상에서 국소 세굴을 발생시킨다. 이를 방지하기 위해 횡단구조물 하류에 굴요성 구조(flexible structure)인 돌망태, 블록공, 사석 등으로 이루어진 바닥보호공(bed protection)이 설치되나 유실, 침하 등의 문제가 빈번히 발생되고 있어, 문제를 해결하기 위한 연구가 필요하다. 본 연구는 이러한 피복 대책에서 일어날 수 있는 파괴 기구인 전단파괴, 흡출 파괴, 경계 파괴, 하상 형태 변화에 따른 하부 침식 중 흡출 파괴(winnowing failure)를 유발하는 흐름을 검토하기 위한 수치모의를 수행하였다. 이때 흡출 파괴는 바닥보호공의 공극으로 미세한 하상 재료가 난류와 침투류의 작용에 의해 침식되어 바닥보호공이 침하되는 것을 말한다. 수치모의는 전산유체동역학(Computational Fluid Dynamics, CFD) 모형인 FLOW-3D 모형을 이용하였으며, 난류 모형으로 LES 모형을 적용하고 조밀한 격자를 부여하여 바닥보호공의 공극에서 발생되는 비교적 작은 척도의 와(vortex)를 해상할 수 있도록 하였다. 수치모의에 적용된 횡단구조물은 보, 물받이공, 바닥보호공으로 구성하였으며 특히, 바닥보호공의 형상은 구체(sphere)로 가정하여 다층으로 배치하였다. 바닥보호공의 공극 또는 구체 사이에서 발생되는 유속, 압력 등의 흐름특성을 분석한 결과, 바닥보호공 두께가 두꺼울수록 흡출 파괴에 대해 안정적인 것으로 나타났다. 이는 바닥보호공 설계를 위한 기초자료로 활용될 수 있으며, 향후 입자영상유속계(Particle Image Velocimeter, PIV)와 같이 공극에서 흐름을 측정할 수 있는 방법과 병행한 연구를 수행할 수 있을 것이다.

  • PDF

Proposal of Domestic Road Bridge Deck Deterioration Models and Forecast of Replacement Demand (국내 도로교량 바닥판 열화모델 제안 및 교체 수요 예측)

  • Kim, Jin-Kwang;Jang, Il-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.61-68
    • /
    • 2017
  • Bridge decks are members that rapidly deteriorated due to various environmental factors such as heavy vehicle and deicing salt, etc. As the lifespan of bridges built in Korea increases, it is expected that the demand for replacing the deteriorated bridge decks will increase. In other countries, Accelerated Bridge Construction technology using precast decks is already actively being used as a countermeasure for replacement demand of deteriorated bridge decks. In this study, bridge decks deterioration models are proposed by collecting and analysing the condition index data of domestic bridge decks. Also, the future replacement demands of deteriorated bridge decks in terms of replacement time and replacement scale are predicted.

Analytical Modelling of Construction Structure Controlling Camber of Long-width Exterior Precast Panel (장폭 외측 프리캐스트 패널 캠버 조정을 위한 가설구조의 해석모델)

  • Won, Tae-Gun;Won, Dae-Yon;Kim, In-Soon;Lim, Yun-Mook
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.293-296
    • /
    • 2010
  • 일반 교량에 주로 사용되는 콘크리트 바닥판 시공을 위해서는 동바리, 거푸집 등을 설치하고 철근 배근 후 콘크리트를 타설하는 방법이 사용되어왔다. 그러나 기존 콘크리트 바닥판 시공은 계절 및 기후의 영향을 많이 받는다. 또한 시공과정에서 많은 인력이 요구되고 시공 안전성 확보를 위한 노력이 필요한 실정이다. 이러한 문제점을 극복하기 위하여 최근에 프리캐스트 바닥판을 이용한 교량 시공이 늘어나고 있는 추세이다. 프리캐스트 바닥판은 공장에서 선제작한 후 현장에서 조립하여 시공한다. 따라서 프리캐스트 바닥판 시공은 계절 및 기후의 영향을 최소화 하여 공기를 단축할 수 있고, 공장제작에 따른 양호한 품질도 보장된다. 또한 인력이 적게 요구되면서 시공 안전성도 확보할 수 있다. 그러나 이러한 기존의 프리캐스트 바닥판은 패널의 폭이 좁고 외측 캔틸레버부의 시공 시 별도의 지보공이 필요한 단점을 갖고 있었다. 이러한 단점을 보완하기 위해 장폭 외측 프리캐스트 바닥판이 제안되었다. 장폭 외측 프리캐스트 바닥판은 패널의 폭을 늘려서 장폭의 바닥판을 만들고, 가설구조물을 이용하여 지보공 없이 시공이 가능하게 고안되었다. 본 연구에서는 장폭 외측 프리캐스트 패널 캠버 조정에 사용 될 가설구조의 현장적용을 위하여, 실험 후 유한요소해석을 수행하여 비교 및 검증하였다.

  • PDF

Variation Characteristics of Floor Impact Sound by Ceiling Structures in Apartment Buildings (공동주택에 천장구조에 의한 바닥충격음 변화특성에 관한 연구)

  • 조창근
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.13-16
    • /
    • 1993
  • 본 연구에서는 공동주택의 바닥충격음 차음성능 향상을 위한 설계자료의 제시를 위해 천장구조가 서로 다른 공동주택을 대상으로 경량 및 중량 바닥충격음의 현장측정을 통하여 공동주택의 천장구조에 의한 바닥충격음 변화특성을 분석하고 차음성능을 평가하였다. 측정대상 건물에서 천장을 설치한 경우가 비교적 높은 충격음 차음성능 분포를 보이는 것으로 나타났으며, 바닥슬래브 하부 천장에 공기층과 완충재를 함께 설치하는 것은 기존 공동주택 등에서 경량 및 중량 바닥충격음 차음성능을 향상시키기 위한 효과적인 방안임을 확인하였다.

  • PDF