• Title/Summary/Keyword: 바닥두께

Search Result 222, Processing Time 0.032 seconds

Evaluation of floor impact sound and airborne sound insulation performance of cross laminated timber slabs and their toppings (구조용 직교 집성판 슬래브와 상부 토핑 조건에 따른 바닥충격음 및 공기전달음 평가)

  • Hyo-Jin Lee;Yeon-Su Ha;Sang-Joon Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.6
    • /
    • pp.572-583
    • /
    • 2023
  • Demand for wood in construction is increasing worldwide. In Korea, technical reviews of high-rise Cross Laminated Timber (CLT) buildings are under way. In this paper, Floor Impact Sound Insulation Performance (FISIP) and Transmission Loss (TL) of 150 mm thick CLT floor panels made of two domestic species, Larix kaempferi and Pinus densiflora, are investigated. The CLT slabs were tested in reverberation chambers connected vertically. When comparing Single Number Quantity (SNQ) of FISIP of the bare panels, the Larix CLT is 3 dB lower in heavy-weight and 1 dB in light-weight than the Pinus CLT. However, there was no difference when concrete toppings were added to improve the performance. As the concrete toppings became thicker, the heavy-weight was reduced by 9 dB ~ 20 dB, and the light-weight by 20 dB ~ 30 dB. And the analysis of these results with area density has confirmed that the area densities are highly correlated (R2 = 0.94 ~ 0.99) to the FISIP of the CLT. The types of CLT didn't affect the TL. Comparison of theoretical TL values with measured TL values has shown that the frequency characteristics are similar but 8 dB ~ 12 dB lower in measured values. The relationship between the TL and frequency characteristics of the tested CLT slabs was derived by using the correction value.

An Efficient High-Frequency Vibration Analysis of Floors in Building Structures (고차의 진동하중을 받는 건축물 바닥판의 효율적인 진동해석)

  • Lee, Dong-Guen;Kim, Tae-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.10 no.5 s.51
    • /
    • pp.35-48
    • /
    • 2006
  • The object of this study is to propose the efficient method for analyzing the building floors subjected to the loading with high frequency contents. For this purpose, the method for mesh division and the selection of master DOF for FE model of building floors with these loadings are studied. Also, it is verified that the availability of thin plate element that is used by structural engineers for the modelling of the building floor of which the span-thickness ratio is usually ten times and over. And the possibility and limit of the equivalent plate which is already studied by other researcher for the multi-layer plate are investigated. At last, proposed modelling method is examined by the example structure.

Numerical Study on the Design Safety of $9\%$ Nickel Based Inner Tank Bottom Plate in Terms of Hydrostatic Pressure (유체정압을 고려한 $9\%$ 니켈강재 내부탱크 바닥판의 설계 안정성에 관한 수치적 연구)

  • Kim Chung Kyun;Kim Han Goo
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.2 s.23
    • /
    • pp.35-41
    • /
    • 2004
  • This paper presents the stress and deformation characteristics of $9\%$ nickel based inner tank bottom plate in full containment LNG storage tank. When a . maximum hydrostatic pressure applies the bottom plate of inner tank, the maximum = f stress and displacement distributions of the bottom plate have been analyzed as ' functions of inclined angle of the bottom plate, and the thickness and length of the annular plate between the shell plate and bottom one. The calculated results indicate that the taper of the bottom plate is recommended by 100${\~}$200 : 1 for $140,000m^3$ storage capacity of the inner tank. The results recommend that the thickness of the annular plate is around 20mm and the length is greater than 3m for a maximum hydrostatic pressure of $140,000m^3$ tank capacity.

  • PDF

Manufacture and Application of UV-Cured Anti-cigar burning Coating Compounds for PVC Tile (PVC 바닥상재용 광경화형 내열 코팅액의 제조 및 응용에 관한 연구)

  • Park, Bo-Ram;Ha, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.608-613
    • /
    • 2010
  • This study is on development of UV-cured water soluble coating composition which have more improved anti-cigar burning to prevent a surface of PVC tile from damage of heat. To make an anti-cigar burning coating solution, thermostable agent that synthesize main materials phosphorus compound, guanidine and ammonium phosphate dibasic used temporary flame retardants, changing their contents from 10 to 30wt% against quantities of resin and compounded. After coating PVC tiles using bar-coating method that can adjust a thickness, we estimated surface properties of coated layer such as anti-cigar burning, adhesive power, chemical resistance, thickness of coating, and so on. Results showed that a coating composition added 30 wt% of phosphorus compound and coated with No.12 bar-coater had the best optimized surface property in anti-cigar burning effect, adhesive power and chemical resistance. Also, we could find anti-cigar burning effect was improved as thermostable agents content and coating thickness increased.

Practical Vibration Analysis of Deck Floor Slab (데크 바닥판 구조물의 실용적인 진동해석)

  • Kim, Gee-Cheol
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.1
    • /
    • pp.61-69
    • /
    • 2005
  • As long-span and light-weight deck floor slab are flexible and have low inherent damping, the significant floor vibration could be induced by residents' activities. These floor vibrations affect to safety and serviceability of building structures. So the vibration criteria are applied to the quality assessment of building structure. Therefore, the accurate vibration analysis should be performed for the correct assessment of deck floor slab. In this paper, practical analysis method with considering orthotropic rigidity of deck floor is proposed tot the accurate vibration analysis of dock floor slabs with form deck plates.

An Experimental Study on Static Behaviors of Composite Sandwich Bridge Decks with Hybrid GFRP-Steel Core (하이브리드 GFRP-강재 심재를 갖는 복합샌드위치 교량바닥판의 정적거동에 관한 실험 연구)

  • Ji, Hyo-Seon;Chun, Kyung-Sik;Park, Dae-Yong;Son, Byung-Jik
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.12-17
    • /
    • 2011
  • This paper presents the flexural behavior of a hybrid Glass Fiber-Reinforced Polymer(GFRP)-steel decks for use in deteriorated bridge decks replacement. Static load tests were conducted to investigate the structural characteristics of the hybrid FRP-steel deck. The tested deck panel satisfied the design criteria. The failure mode of the hybrid deck was demonstrated ductility with deformation beyond initial yielding. The responses were compared with the ANSYS finite element predictions. It was found that the presented hybrid deck was efficient for use in bridges. The thickness of the hybrid deck may be decreased when compared to that of the all FRP deck with similar flexural rigidity.

Numerical Simulation for Bed Protection Design (바닥보호공 설계를 위한 수치모의)

  • Ha, Sung Won;Kim, Tae Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2016.05a
    • /
    • pp.345-349
    • /
    • 2016
  • 보본체와 물받이공을 보호하는 바닥보호공(bed protection)은 굴요성 구조(flexible structure)인 돌망태, 블록공, 사석 등으로 설치되어야 하며, 일반적으로 경제성과 시공성이 우수한 사석(riprap)이 많이 이용된다. 이때 사석의 안정성 확보를 위한 설계기준으로 국내의 경우 포설길이에 대해서만 제시하고 있으나, 외국의 경우 수심, 유속 등의 값을 기초로 사석의 크기, 포설두께, 포설길이를 산정할 수 있도록 상세하게 제시하고 있다. 이와 같은 실정으로 국내 하천 실무자들이 바닥보호공을 설계 할 때 하천설계기준을 바탕으로 블라이 공식 또는 국립건설시험소 공식을 적용하여 사석의 포설길이는 산정하지만 사석의 크기, 중량 등의 제원들은 외국 설계기준을 차용하여 산정하거나 생략하는 경우도 있다. 따라서 하천설계기준의 보완 및 최근 국내 주요하천에서 발생하는 바닥보호공 유실, 침하 등의 문제를 해결하기 위한 연구가 필요하다. 본 연구는 전산유체동역학(Computational Fluid Dynamics, CFD) 모형인 FLOW-3D 모형을 이용하여, 바닥보호공 주변 흐름에 대한 수치모의를 수행하였다. 이때 난류 모형은 LES (Large Eddy Simulation) 모형을 적용하였으며, 바닥보호공에 작용하는 비교적 작은 척도의 와(vortex)를 해상할 수 있도록 조밀한 격자를 부여하였다. 초기 수치모형 결과의 적정성은 수리실험 결과와 비교하여 판단하였으며, 수리실험을 잘 재현해내는 격자, 매개변수 등을 적용하여 보의 하류 수위 변화에 따른 유속, 난류강도 등에 대한 분석을 수행하였다. 본 연구 결과는 바닥보호공 설계를 위한 기초자료로 활용될 수 있으며, 향후 수리실험과 병행하여 국내 실정에 맞는 설계식 개발에 대한 연구가 필요한 것으로 보인다.

  • PDF

Theoretical Assessment of Limit Strengthening Ratio of Bridge Deck Based on the Failure Characteristic (교량 바닥판의 파괴형태를 고려한 임계보강재비의 이론적 산정)

  • 심종성;오홍섭;유재명
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.1
    • /
    • pp.110-117
    • /
    • 2002
  • In a strengthened bridge deck which received increased service loads, failure patterns of bridge deck vary depending on deck thickness, compressive strength of concrete, yielding strength of reinforcement, reinforcement ratio and additional strengthening ratio. General failure pattern that is most commonly reported as punching shear failure after the main rebar yields, followed by yielding of distributing rebar. In this paper, by Proposing a limit to the amount of strengthening material, a brittle failure can be prevented and a ductile failure mode similar to that developed in unstrengthened deck is derived. In order to calculated the limit strengthening ratio, the yield line theory and previously proposed plastic punching shear model have been used

Evaluation of Floor Vibration Existing in Apartment Building (기존 아파트 바닥의 수직진동 성능 평가)

  • Han Sang Whan;Lee Min Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.221-228
    • /
    • 2004
  • In recent years building floors become larger and more spacious due to the development of new design methods and high strength and light weight materials. However, such long span floor systems may provide smaller amount of damping and have a longer period so that they may be more vulnerable to the floor vertical vibration. In Korea when floors are to be checked against the floor vertical vibration, the provisions developed in foreign countries have been used. However these guidelines have been developed based on human perception, which may vary from country to country. Also, Korea have particular floor systems, such as flat plate floor system of apartment building. This study attempts to evaluate the vibration performance of the floors in typical apartment buildings. Two different floors with the area of $28 m^2$ and $32 m^2$ were investigated. The criteria provided by ATC-1(1999), AISC-11(1997), AIJ(1991) and the local criteria developed in the previous study(Han, 2003) was used to check the acceptability of the floor vertical vibration.

Effects of Bedding Thickness of Sawdust on Environment of Cowshed Floor and Productivity of Hanwoo (깔짚 두께가 한우사 바닥환경과 생산성에 미치는 영향)

  • Kim, Seung-Gi;Park, Byung-Ki;An, Jun-Sang;Park, Myung-Ho;Ra, Chang-Six;Shin, Jong-Suh
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.65-72
    • /
    • 2012
  • This study was conducted to investigate the effects of bedding thickness of sawdust on feed intake, blood metabolites concentration and environmental condition of cowshed floor for Hanwoo. Feed intake was increased at thicker bedding groups (15 or 20cm), compared with thinner bedding group (10cm). The thicker bedding had a positive effect on concentration of serum total protein, high density lipoprotein (HDL)-cholesterol, low density lipoprotein (LDL)-cholesterol and ${\gamma}$-glutamyltransferase (GGT). Moisture content and the number of E. Coli in the bedding material were remarkably lower in 15 and 20 cm groups, compared with 10 cm group. Based on the data obtained in this study, approximately 20 cm bedding thickness or at least over 15 cm would be maintained to improve the health condition of Hanwoo and hence to enhance the productivity.