This paper presents the flexural behavior of a hybrid Glass Fiber-Reinforced Polymer(GFRP)-steel decks for use in deteriorated bridge decks replacement. Static load tests were conducted to investigate the structural characteristics of the hybrid FRP-steel deck. The tested deck panel satisfied the design criteria. The failure mode of the hybrid deck was demonstrated ductility with deformation beyond initial yielding. The responses were compared with the ANSYS finite element predictions. It was found that the presented hybrid deck was efficient for use in bridges. The thickness of the hybrid deck may be decreased when compared to that of the all FRP deck with similar flexural rigidity.

본 논문은 노후교량바닥판 대체용으로서 하이브리드 GFRP-강재 바닥판의 휨거동을 구조적 거동특성을 기술하고 있다. 하이브리드 GFRP-강재 바닥판의 구조적 특성을 조사하기 위해 정적하중의 실험적 연구를 수행하였다. 하이브리드 바닥판의 파괴모드는 초기항복을 지나서 연성거동을 나타내었다. 결과는 유한요소프로그램 ANSYS의 값과 비교하였다. 제안된 하이브리드 바닥판이 교량적용에 유용함을 확인하였다. 하이브리드 바닥판의 두께는 유사한 휨 강성을 갖는 완전복합신소재 바닥판께와 비교하였을 때 감소될 수 있었다.

Keywords

References

  1. 이성우, 김병석, 조남훈, "인발성형 중공단면 복합소재 교량바닥판의 구조적 특성분석", 대한토목학회논문집, 제26권 제1A호, 2008 ,pp. 35-43.
  2. 정진우, 김영빈, 이재홍, "GFRP 복합재료를 이용한 조립식 교량 바닥판의 실험 연구", 한국강구조학회논문집, 제17권, 3호, 2005, pp. 337-346.
  3. 지효선, 손병직, 장석윤 "노후화된 교량 바닥판 대체용 복합신소재 교량 바닥판의 거동에 관한 실험적 연구", 한국강구조학회논문집, 제13권, 6호, 2001, pp. 631-640.
  4. 지효선, 천경식 "노후교량 바닥판 대체용 Modular GFRP 바닥판 거동에 관한 실험 연구", 한국복합신소재구조학회논문집, 제1권, 2호, 2010, pp. 44-50.
  5. Alagusundaramoorthy, P., Harik, I.E., and Choo, C.C. "Structural behavior of FRP composite bridge deck panels" ASCE Journal of Bridge Engineering, Vol. 11, No. 4, 2006, pp. 384-393. https://doi.org/10.1061/(ASCE)1084-0702(2006)11:4(384)
  6. Aref, A.J., Kitan, Y., Lee, G.C. "Analysis of hybrid FRP-concrete multi-cell bridge superstructures," Composite Structures, Vol 69, 2005, pp. 346-359. https://doi.org/10.1016/j.compstruct.2004.07.025
  7. AASHTO LRFD. (2007). AASHTO LRFD bridge design specifications, 4th Ed., AASHTO, Washington D.C.
  8. ANSYS Ins. (2005). ANSYS 10.0 documentation ANSYS Inc. distributed with ANSYS 10.0.
  9. Burgueno R., Karbhari V.M., Seible F., and Kolozs R.T. "Experimental dynamic characterization of an FRP composite bridge superstructure assembly," Composite Structures, Vol 54, 2001, pp. 427-444. https://doi.org/10.1016/S0263-8223(01)00115-5
  10. Ji, H.S., Song, W.C. and Ma, Z. John, " Design, Test and Field Application of a GFRP Corrugated-Core Sandwich Bridge", Engineering Structures, Vol.32, No.9, 2010, pp. 2814-2824. https://doi.org/10.1016/j.engstruct.2010.05.001
  11. Zi, G., Kim, B.M., Hwang, Y.K., and Lee, Y.H. "An experimental study on static behavior of a GFRP bridge deck filled with a polyurethane foam", Composite Structures, Vol 82, 2008, pp. 257-268. https://doi.org/10.1016/j.compstruct.2007.01.010