• Title/Summary/Keyword: 밀폐

Search Result 1,241, Processing Time 0.041 seconds

Heating Efficiency of Difference Heat Collection Methods for Greenhouse (유리온실의 태양열 집열방법별 집열효과)

  • 최영하;이재한;권준국;박동금;이한철
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.166-170
    • /
    • 2000
  • Three methods for heat collection, which were the flat solar collector, two fan with radiator, and square pipe method, were studied to sue efficiently solar energy in the three different glasshouses for two years. The flat plate solar collector method was made use of the commercial solar collector with collection area of 24$m^2$, the method of two fans with radiators collected solar energy at the top of the glasshouse. An thermal storage tank was constructed underneath in teach glasshouses. When an area of 1,000$m^2$ was heated to the minimum temperature of 9$^{\circ}C$, the decrease rate of heating fuel for the flat plate solar collector, the fan attached radiator and the square pipe methods were 7%, 19% and 28% respectively. The flat plate solar collector method, which could be heated approximately 40-50$m^2$, was currently used by most of the farmer. Under the condition, the decrease rate of annual heating fuel was 14% which was not better for an economic annual heating fuel. If the fan with radiator method was operated, the use of installation and maintenance were required. So, it could not be good economic efficiency of solar heating. The heating efficiency of the square pipe method was relatively better thant those of the flat plate solar collector or the fan attached radiator. Since the cost of materials and its installation of the use of square pipe method was lower than any other method. However, corrosion of the pipe, greater shade in the greenhouse and strength against the square pipe were problems that should be overcome in the square pipe method.

  • PDF

Worker Exposure and Volatilization Pattern of Cadusafos, Ethoprophos and Probenazole after Applying Granular Type Formulation on Soil in Greenhouse (시설재배지에서 토양처리농약 Cadusafos, Ethoprophos와 Probenazole 입제 처리 후 휘산 양상과 농작업자 노출)

  • Park, Byung-Jun;Lee, Ji-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.160-165
    • /
    • 2011
  • BACKGROUND: This study carried out to fate of pesticide and investigate worker exposure of pesticide in air after applying granular type pesticide formulation on soil in greenhouse for preventing farmer's pesticide intoxication. METHODS AND RESULTS: The recovery of pesticide, cadusafos, ethoprophos and probenazole on absorbent in air were ranged 80.9~121.1% in charcoal and 90.6~99.0% in XAD-4, respectively. Emission rate of in lysimeter was higher 3~5 times than that of pesticides from topsoil not added water at $35^{\circ}C$ plot after applying a mixture of granular formulation and soil. The ethoprophos concentration in air, 50 cm high from soil surface at greenhouse, was reached the highest 186.4 ${\mu}g/m^3$ within 13 hours and were ranged 17.8~186.4 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 150 g a.i./245 $m^2$. The cadusafos concentration in air at greenhouse was reached the highest 37.3 ${\mu}g/m^3$ within 39 hours and were ranged 10.0~37.3 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 180 g a.i./245 $m^2$. The probenazole concentration in air at greenhouse was reached the highest 1.45 ${\mu}g/m^3$ within 37 hours and were ranged 0.23~1.45 ${\mu}g/m^3$ during 46 hours after applying granular formulation at dose rate 144 g a.i./245 $m^2$. CONCLUSION(s): The result of the reentry interval study demonstrated that reentry intervals for ethoprophos and cadusafos are longer than 48 hours.

Mechanism by which periodontitis may contribute to atherosclerosis (치주염이 동맥경화에 기여하는 기전에 관한 연구)

  • Han, Seung-Hee;Kim, Kyung-Hwa;Yang, Seung-Min;Chung, Hyun-Ju;Choi, Yoon-Sik;Han, Soo-Boo;Chung, Chong-Pyoung;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.4
    • /
    • pp.837-846
    • /
    • 2002
  • 그람 음성균의 감염에 의한 만성 염증질환인 치주염이 동맥경화를 동반한 허혈성 심장질환 (협심증이나 심근 경색)을 일으킬 수 있는 위험인자로 작용할 수 있다는 보고가 있었다. 그러나, 그 기전에 관해서는 명확하게 알려져 있지 않다. 작용기전의 하나로서, 치주염에 의해 치주조직에서 국소적으로 생긴 염증성 싸이토카인(IL-1${\beta}$, IL-6, $PGE_2$, TNF-${\alpha}$)이 혈행을 따라 이동하여 심혈관에서 동맥경화를 일으킬 수 있다는 가설이 제시되고 있는데, 이 가설을 검증해 보고자 한다. 서울대학교 병원 순환기 내과에 불안정 협심증이나 심근경색으로 입원한 환자 및 과거 이 질환의 병력을 갖고 있거나 검진 목적으로 내원하여 관상동맥 조형술을 받은 환자들 중 동맥경화로 진단받은 사람을 실험군(24명)으로 하고, 동맥경화로 진단받지 않은 사람을 대조군(12명)으로 하였다. 치주질환의 활성도를 나타내는 치은 지수, 치태 지수, 치주낭 깊이, 부착 상실을 측정하였다. Paper strip을 실험대상 치아(Ramfjord's teeth)들 중에서 가장 깊은 치주낭을 가진 두 개의 치아를 택하여 각 치아의 가장 깊은 치주낭에 30초간 삽입한 후 밀폐된 plastic tube에 넣고 ELISA kit를 이용하여 IL-1${\beta}$, IL-6, TNF-${\alpha}$, $PGE_2$의 농도를 측정하였다. 환자의 plasma에서도 동일한 싸이토카인의 농도를 측정하였다. 설문조사를 통해 동맥경화의 위험 인자로 간주되어온 고혈압, 당뇨, 가족력, 심근경색이나 협심증의 기왕력, 흡연의 유무를 기록하였다. 혈액검사를 하여 total cholesterol, triglycerides, LDL cholesterol, HDL cholesterol, WBC, CRP (C-reactive protein)의 농도를 측정하였다. 치주조직에 대한 임상 검사 결과 치은의 염증상태를 나타나는 지표인 치은 지수에서만 실험군이 대조군에 비해 유의할 정도 (p=0.0174)로 높게 나타났고, 만성적인 염증의 결과로 인한 치조골의 사실 정도를 나타내는 치주낭 깊이나 부착 상실에서는 유의할 만한 차이를 보이지 않았다. 치주낭에서 측정한 염증성 싸이토카인 중 IL-1${\beta}$, $PGE_2$가 실험군에서 유의할 만한 차이 (p=0.005, 0.022)를 보이며, 더 높은 농도로 나타났고, TNF-${\alpha}$는 대조군에서 유의성 있게 (p=0.009) 높게 나타났다. 그러나, plasma의 싸이토카인이나, serum lipid/lipoprotein, C-reactive Protein, WBC는 유의할 만한 차이를 보이지 않았다. 또한 치은열구액내의 싸이토카인과 이에 상흥하는 싸이토카인 간에 상관관계는 관찰되지 않았다. 다변량 로지스틱 회귀분석 결과, 치은열구액내의 IL-1${\beta}$와 TNF-${\alpha}$ 만이 동맥경화와 유의성 있는 관련성을 보였고, 특히 IL-1${\beta}$와 교차비는 273으로 상당한 관련성을 보여주었다. 결론적으로, 치주조직에서 국소적으로 생긴 염증성 싸이토카인이 그대로 혈행으로 이동하여 혈장내의 싸이토카인 농도를 높이는 것은 아니다. 그러나, 치주염으로 인해 치은열구내액내에 국소적으로 증가된 염증성 싸이토카인은 동맥경화와 상당한 관련성을 가진다.

The effects of tissue punch diameter on healing around implants in flapless implant surgery (무피판 임플란트 수술에서 연조직 펀치의 크기가 임플란트 주위 조직의 치유에 미치는 영향)

  • Lee, Du-Hyeong;Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.301-311
    • /
    • 2009
  • Statement of problem: Flapless implant surgery using a soft tissue punch device requires a circumferential excision of the mucosa at the implant site. To date, Although there have been several reports on clinical outcomes of flapless implant surgeries, there are no published reports that address the appropriate size of the soft tissue punch for peri-implant tissue healing. Purpose: In an attempt to help produce guidelines for the use of soft tissue punches, this animal study was undertaken to examine the effect of soft tissue punch size on the healing of peri-implant tissue in a canine mandible model. Material and methods: Bilateral, edentulated, flat alveolar ridges were created in the mandibles of six mongrel dogs. After a three month healing period, three fixtures (diameter, 4.0 mm) were placed on each side of the mandible using 3 mm, 4 mm, or 5 mm soft tissue punches. During subsequent healing periods, the peri-implant mucosa was evaluated using clinical, radiological, and histometric parameters, which included Gingival Index, bleeding on probing, probing pocket depth, marginal bone loss, and vertical dimension measurements of the peri-implant tissues. Results: The results showed significant differences (P <0.05) between the 3 mm, 4 mm and 5 mm tissue punch groups for the length of the junctional epithelium, probing depth, and marginal bone loss during healing periods after implant placement. When the mucosa was punched with a 3 mm tissue punch, the length of the junctional epithelium was shorter, the probing depth was shallower, and less crestal bone loss occurred than when using a tissue punch with a diameter $\geq$ 4 mm. Conclusion: Within the limit of this study, the size of the soft tissue punch plays an important role in achieving optimal healing. Our findings support the use of tissue punch that 1 mm smaller than implant itself to obtain better peri-implant tissue healing around flapless implants.

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.6
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.

Propagation Efficiencies at Different LED Light Qualities for Leaf Cutting of Six Echeveria Cultivars in a Plant Factory System (에케베리아 6품종의 엽삽 시 식물공장시스템 내 LED 파장에 따른 번식 효율)

  • Kim, Seongmin;Kim, Jiseon;Oh, Wook
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.363-370
    • /
    • 2018
  • The succulent plants of Echeveria genus are in increasing demand worldwide, but it is difficult to supply good quality young plants throughout the year because propagation efficiencies are depend on cultivar and environmental factors. This study was carried out to investigate the propagation efficiencies of leaf cutting in Echeveria cultivars at different LED light qualities in a closed-type plant factory system. Leaf cuttings cut from stock plants of six difficult-to-propagated cultivars 'Afterglow (AG)', 'Berkeley Light (BL)', 'Mason (MS)', 'Subsessilis Light (SL)', 'Cream Tea (CT)', and 'Ben Badis (BB)' were put into cutting media in the plant factory system maintained at a temperature of $24{\pm}2^{\circ}C$ and relative humidity of $60{\pm}10%$, and watered with over-head irrigation twice a week. Cuttings were irradiated with sole or mixed red (R, 660 nm), blue (B, 450 nm), green (G, 530 nm), and far-red (FR, 730 nm) LEDs as follows: R10, R8+B2, R5+B5, R7+B2+FR1, and R7+B2+G1. PPFD just above the cuttings was $200{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and photoperiod was 16/8 (light/dark) hours. As a result, propagation efficiencies were dependent on cultivar. Rooting and shooting were relatively easy in 'SL' but shoot formation in 'AG' was very difficult. Light qualities from LEDs also affected plant regeneration. Light conditions with a higher ratio of B, R5+B5, R7+B2+FR1, and R7+B2+G1, promoted shoot formation and growth but inhibited rooting and root growth. R10 and R8+B2 with a higher ratio of R promoted rooting and root growth and inhibited shoot formation and growth of cuttings. In addition, the treatment with FR increased leaf size and biomass of the all plants. Therefore, further studies are needed to investigate the optimum compositions of LED light quality for the improvement of leaf cutting efficiency in difficultto-propagated Echeveria cultivars.

Possibility of Soil Solarization in Korea (한국(韓國)에 있어서 태양열(太陽熱)을 이용(利用)한 토양소독(土壤消毒)의 가능성(可能性))

  • Ki, Kye-Un;Kim, Ki-Chung
    • Korean journal of applied entomology
    • /
    • v.24 no.2 s.63
    • /
    • pp.107-114
    • /
    • 1985
  • This experiment was performed to see the possibility if soil-borne disease in green house can be controlled by soil solarization in Korea. Thermal death profiles of propagules of some soil-borne fungi, Fusarium oxysporum f. lycopersici, Fusarium oxysporum f. niveum, Rhizoctonia salani, Sclerotinia sclerotiorum, Sclerotium rolfsii and Pythium debaryanum, were obtained under the conditions in water-suspension and in soil. Except Pythium debaryanum, all the fungal units in water-suspension that were colonized on barley grains lost a viability within 7 days in water bath at $45^{\circ}C$. When the soil in test tubes in which barley grains infected with the fungi were also buried all the fungi tested including Pythium debaryanum were completely killed within 7 days in water bath at $45^{\circ}C$. From July to August in Korea, soil temperature at depth of 5cm and 15cm within tunnel in plastic house reached $38^{\circ}C\;to\;57^{\circ}C$ and $40^{\circ}C\;to\;47^{\circ}\C$, in 1982 and 1983 respectively. Even at 15cm depth, soil temperature were kept over $43^{\circ}C$ for 12 hours a day. Adiabatic material set under ground or under mulching with the transparent polyethylene-film on the soil surface had a boostering effect for higher soil-temperature and longer duration. Fungi buried in adiabatic block of the soil in plastic house were completely killed at 15cm depth 14 days after, and at 20cm depth 21 days after soil solarization. The exposure of the pathogens to fluctuating temperature was much more effective than to constant. From the above results, soil-borne diseases may be effectively controlled by soil solarization in the closed plastic house in hot summer season in Korea.

  • PDF

The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin (첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향)

  • Kim, Min-Chul;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.197-207
    • /
    • 2011
  • The study aimed at examining how different reline resins affect flexural strength and flexural modulus of denture base. A total of 80 specimens ($64{\times}10{\times}3.3$ mm, according to ISO 1567:1999) of heat-polymerized resin, 40 specimens for (Lucitone199(Dentsply Int., NewYork, USA), SR Ivocap(Ivoclar AG, Schaan, Liechtenstein)) respectively, were polymerized according to the manufacturer's instructions and divided into eight groups(n = 10). Control group specimens remained intact. Specimens in the other groups were abraded on both sides to 2 mm thickness, and were relined in 1.3 mm thickness with 3 types of resins (Lucitone199(Dentsply), SR Ivocap(Ivoclar), and Rebase II(Tokuyama Co., Ltd, Tokyo, Japan)). All specimens were preserved in distilled water at $37^{\circ}C$ for 50 hours, and then were subjected to flexural strength testing in a universal testing machine using 3-point loading. A crosshead speed of 5 mm/min was used, and the distance between the supports was 50 mm. Data analyses included one-way analysis of variance(ANOVA) and the Tukey Honestly Significant Difference test (p=.05). Both heat-polymerized resin groups and auto-polymerized resin groups showed statistically low flexural strength and flexural modulus than control groups. Specimens relined with Lucitone 199 showed significantly higher flexural strength and flexural modulus than those relined with SR-Ivocap. Specimens relined with auto-polymerized resin showed significantly lower flexural strength and flexural modulus than those relined with heat-polymerized resin. Relining with heat-polymerized resins showed superior mechanical properties to relining with an auto-polymerized resin. Relining with the same heat-polymerized resin as the denture base does not affect mechanical properties of a denture. Lucitone199 using a compression-mould technique resulted in the highest flexural strength.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.