• Title/Summary/Keyword: 민감도 측정

Search Result 1,700, Processing Time 0.051 seconds

Effects of Scintillation Crystal Surface Treatments on Small Gamma Camera Imaging (섬광체 옆 표면처리가 소형 감마카메라 영상에 미치는 효과)

  • Kim, J. H.;Choi, Y.;Kim, J. Y.;Oh, C. H.;Kim, S. E.;Choe, Y. S.;Lee, K. H.;Joo, K. S.;Kim, B. T.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.6
    • /
    • pp.515-521
    • /
    • 1999
  • Scintillator crystal is an important part and detcrmines performance characteristics of the gamma camera. We investigated the offects of scintillation crystal surface treatment on gamma camera imaging. Nal(TI) and Csl(Tl) scintillators. 20 mm diameter and 10 mm thickness, applied with two different surface treatments, white and black reflcetors, were applied to Nal(Tl) and Csl(Ti). The optical properties of generated scintillation light were evaluated by Monte Carlo simulation method and by actual measurement using a position sensitive photomultiplier tube (PSPMT). We measured sensitivity, energy resolution and spatial resolution of gamma camera with the various scintillators coupled to a PSPMT. In the simulation. Nal(Tl)-white prosented the best sensitivity. In the measurements, the sensitivities and the intrinsic spatial resolutions of Nal(Tl)-white, Nal(Tl)-black. CsI(Tl)-white, CsI(Tl)-black were 2920, 2322, 1754, 1401 cps/$\mu$ci and 5.2, 4.5, 7.0, 6.3 mm FWHM. respectively. Their intrinsic energy resolutions were mesured 12.5, 23.5, 20.5, 33.3% FWHM at 140 keV Tc-99m. In this study, we investigated the offects of a side surface treatment of the scintillator on the gamma camera imaging. Simulation and measurement prescnted similat trends. Based on the results, we concluded that the surface of th NaI(Tl)seintillator must be treated by absorptive materials in order to develop the gamma camera having good spatial resolution.

  • PDF

Time-Series Neural Network Modeling of Pulsed Ion Energy Pattern and Applications to Plasma Monitoring (펄스드 이온에너지 패턴의 신경망 시계열 모델링과 플라즈마 감시에의 응용)

  • Kim, Su-Yeon;Kim, Byung-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1855-1856
    • /
    • 2008
  • 본 연구에서는 공정 중에 민감하게 반응하는 플라즈마로부터 수집되는 이온에너지 분포(IED : Ion Energy Distribution)와 시계열 신경망 모델링을 결합한 플라즈마 감시 기술을 개발하였다. NIEA(Non-invasive ion analyzer)를 이용하여 IED를 측정하였으며, 모델링에 사용된 신경망은 자기 상관 시계열 신경망(A-NTS : Auto-Correlated Neural Time-Series)이다. 모델 개발을 위한 학습과 테스트 데이터로는 Duty ratio 100%에서 수집한 IED를 이용하였으며, 개발된 모델의 감시 성능은 60%에서 수집된 IED로 평가하였다. 학습인자 k와 m의 범위는 각각 1-3 으로 총 9종류의 (k, m) 조합에 대해서 모델 성능을 평가하였다. 신경망 은닉층 뉴런수는 2-9의 범위에서 최적화하였다. 최적화된 모델은 (2, 3)과 뉴런수 2에서 구해졌으며, 0.335의 예측 에러를 보였다. 60% IED 데이터로 평가한 결과 플라즈마 고장에의 민감도는 62% 이상이었다. 이는 IED의 A-NTS 모델이 플라즈마 고장의 감시에 효과적으로 적용될 수 있음을 의미한다.

  • PDF

Analysis of Emotional Characteristics on Life Environmental Noise I: Structural Analysis of Noise Adjectives (생활공간음의 감성 특성 분석 : 소음 형용사에 대한 차원분석)

  • 민윤기;손진훈
    • Science of Emotion and Sensibility
    • /
    • v.2 no.1
    • /
    • pp.69-75
    • /
    • 1999
  • 본 연구는 우리말 형용사를 이용하여 각종 생활공간음에 대해 느끼는 사람들이 감성적 반응의 차원을 밝히기 위한 기초 연구로 수행되었다. 형용사 사전에서 추출된 어휘들에 대한 적합성 및 유사성 평가를 통해 14개의 형용사가 최종적으로 선정되었고, 이 형용사들의 유사성 점수에 대해 요인분석, 다차원 척도 분석 및 군집분석을 시행하였다. 연구 결과 생활공간음에 대한 사람들의 감성적 반응은 크게 3가지 차원, 즉 쾌-불쾌, 민감-둔감 및 지각된 크기가 추출되었고, 소음에 대해 느끼는 감성은 이들 차원 상에서 측정될 수 있는 것으로 나타났다. 이들 차원들은 서로 직선적인 관계가 있는 것으로 보인다. 즉, 소음에 대해 민감한 사람은 그 소음에 대해 불쾌하거나 짜증을 일으키기 쉽지만 소음에 대해 불쾌하거나 짜즈을 일으킨 사람이 소음에 대해 민감한 사람이라고 볼 수는 없을 것이다. 따라서 이들 차원간에 구체적인 통로분석이 이루어져야 할 것으로 보이며 이는 후속연구에서 밝혀질 것이다. 또한 실제 소음을 제시하여 각각의 소음을 평가하는 경험적 연구도 수행될 것이다.

  • PDF

Evaluation of Enzyme-linked Immunosorbent Assay in Serological Diagnosis of Human Neurocysticercosis using paired Samples of Serum and Cerebrospinal Fluid (면역효소측정법을 이용한 뇌낭미충증의 혈청학적 진단의 평가)

  • 조승열;김석일
    • Parasites, Hosts and Diseases
    • /
    • v.24 no.1
    • /
    • pp.25-41
    • /
    • 1986
  • The applicability of micro-ELISA was evaluated in human neuro-cysticercosis using paired samples of serum and CSF. A total of 355 cases who were mostly neurologic patients was subjected. Cystic fluid of C. cellulosae was used as antigen in protein concentration of $2.5{\;}{\mu}g/ml$. Serum was diluted to 1 : 100 and CSF was undiluted in the assay for the specific IgG antibody level. The differential criterion of the positive reaction was the abs. of o. 18 in both samples. The results were summarized as follows: 1. The overall sensitivity of the micro-ELISA in 71 confirmed neurocysticercosis was 90.1% ; the sensitivity by serum was 77.5% and that by CSF was 83.1%. CSF was a more sensitive and valuable material. Most of the false negative cases of neuro-cysticercosis showed far lower level of abs. rather than marginal. 2. The overall specificity of the micro-ELISA in 52 confirmed other neurologic diseases was 88.5%; the specificities by serum and by CSF were 94.2% respectively. Cases of other neurologic diseases did not show false positive reactions in both samples. 3. When serum was assayed, taeniasis(2/18), sparganosis(2/20), paragonimiasis(1/56), clonorchiasis(1/15) and fascioliasis(1/1) cases showed cross reactions. When CSF was assayed, 2 ot 10 neuro-sparganosis showed cross reactions while none of 9 neuro-paragonimiasis showed it. Out of 71 confirmed neuro-cysticercosis cases, 6 and 11 showed cross reactions by serum and CSF to crude extract antigen of sparganum; but no case did show it to crude extract antigen of Paragonimus westermani. 4. Ventricular CSF showed low or negative levels of IgG antibody than lumbar CSF unless the lesion was at the lateral ventricle itself. 5. Out of 4 racemose cysticercosis cases, 3 showed positive reaction in serum while all of 3 examined CSF were positive. The above results indicated that the serological test for detecting the specific IgG antibody by micro-ELISA using paired samples of serum and CSF was very helpful for clinical differentiation of neuro-cysticercosis from neurologic diseases of other causes.

  • PDF

Mechanical Properties and Microstructural Analysis of Sn-40Bi-X Alloys (Sn-40Bi-X 합금의 기계적 물성과 미세조직 분석)

  • Lee, Jong-Hyun;Kim, Ju-Hyung;Hyun, Chang-Yong
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.79-79
    • /
    • 2010
  • 저온용 무연 솔더의 대표 조성으로 고려되고 있는 Sn-58Bi(융점: $138^{\circ}C$) 공정(eutectic) 조성은 우수한 강도에도 불구하고 연성(ductility) 측면에서의 문제점이 지속적으로 보고되고 있다. 따라서 이 합금계의 연성을 최대로 개선시킬 수 있으면서도 실제 상용화가 가능한 합금 조성의 개발 연구가 요청된다. 본 연구에서는 Sn-Bi 2원계 조성에서 최대의 연성을 나타내는 것으로 보고된 Sn-40Bi 조성에 미량의 합금원소를 첨가함으로써 최대의 연성을 확보하는 한편, 그 연성 특성이 변형속도에 어느 정도 민감한지를 인장 실험을 통해 결정하고자 하였다. 합금원소로는 0.1~0.5 wt%의 Ag, Mn, In, Cu를 선택하였으며, 인장 시편을 제조하여 $10^{-2}$, $10^{-3}$, $10^{-4}\;s^{-1}$의 3종류로 변형속도를 변형시켜가며 응력-변형 곡선(stress-strain curve)을 측정하였고, 조성별, 변형속도별로 최대인장강도(ultimate tensile stress, UTS) 및 연신율 결과들을 정리하였다. 합금원소를 첨가한 조성의 경우는 모든 시험 조건에서 Sn-40Bi보다 우수한 연신률을 나타내는 것으로 측정되었으나, $10^{-2}\;s^{-1}$의 빠른 변형속도에서는 그 향상 정도가 상대적으로 감소하는 경향이 관찰되었다. 특히 Sn-40Bi-0.5Ag 조성의 경우 느린 변형속도에서 특히 눈에 띄는 연신률 값을 나타내며, 모든 변형속도 조건에서 가장 우수한 연성을 나타내었다. 한편 Sn-40Bi-0.1Cu 조성의 경우 변형속도에 따른 연신률의 변화 정도, 즉, 변형속도에 따른 연신률의 민감도가 매우 커 $10^{-4}\;s^{-1}$ 속도에서는 Sn-40Bi-0.5Ag에 버금가는 연신률 값이 측정되었으나, $10^{-2}\;s^{-1}$ 속도에서는 가장 나쁜 연신률 특성을 보여주었다. Sn-40Bi-0.2Mn 조성은 최고의 연신률 향상 특성을 나타내지는 않았으나, In을 첨가한 경우보다는 대체적으로 우수한 연성을 나타내었다. 이상의 각 합금별 연성 특성은 인장시험 전의 미세조직 관찰 결과와 인장시험 후 파면부의 조직변화 관찰 결과로부터 해석되었다. 그 결과 석출상의 형성 여부, 인장 시험 중 재결정 조직의 형성 여부, 라멜라(lamellar) 조직의 분율과 라멜라 간격(lamellar spacing)의 정도 또는 $\beta$-Sn과 라멜라 조직 사이의 결정립계와 라멜라 조직 내 결정립계에서의 슬라이딩 모드(sliding mode) 변형 정도, 석출상의 크기와 분포 정도 등이 연신률 및 변형속도 민감도와 같은 연성 특성에 가장 큰 영향을 미치는 인자인 것으로 분석되었다.

  • PDF

The Usefulness According to the Incubation Time of PTH as Prediction Index of Hypocalcemia (저칼슘혈증 예측지표로서 부갑상선 호르몬 검사반응시간에 따른 유용성)

  • Au, Doo-Hee;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.138-142
    • /
    • 2010
  • Purpose: PTH (parathyroid hormone) level is a useful index for prediction of hypocalcemia after thyroidectomy. The fast results are required for an early diagnosis of hypocalcemia. In this study, we evaluated the PTH change according to incubation time, and investigated the usefulness of hypocalcemia diagnosis of PTH results in early incubation time. Materials and Methods: The subjects were 131 patients who had taken the PTH test from July to August in 2009. All experiments were used IRMA method. PTH value were evaluated with the correlation between precision (10 times repeat) and recovery rate and at 0.5, 3, 6 and $18{\pm}2$ (below overnight) hours following incubation time. Data analysis was investigated with relationship of the sensitivity, specificity, PPV (positive predictive value) and accuracy. Results: The correlation was time-dependent with levels reaching $R^2$=0.987 at 0.5 hours, $R^2$=0.993 at 3 hours and $R^2$=0.996 at 6 hours compare to overnight levels. The precision (%CV${\pm}$SD) were $15.92{\pm}15.54$ at 0.5 hours, $6.91{\pm}7.38$ at 3 hours, $4.30{\pm}4.69$ at 6 hours and $4.59{\pm}2.59$ at overnight. The recovery rate (%Mean${\pm}$SD) were $96.8{\pm}5.44$ at 0.5 hours, $102.6{\pm}4.35$ at 3 hours, $100.7{\pm}2.56$ at 6 hours and $102.2{\pm}5.98$ at overnight. When 15 pg/ml of overnight density was set up as criteria, we measured the sensitivity, specificity and PPV, accuracy at 0.5, 3, 6 hours. The sensitivity was shown to 97.5% at all times. The specificity was 96.0% at 0.5 hours, 100% at 3 hours and 92.3% at 6 hours for control, respectively. The PPV was 86.6% at 0.5 hours, 100% at 3 hours and 92.8% at 6 hours. The accuracy was shown to 84.7% at 0.5 hours, 97.5% at 3 hours and 90.6% at 6 hours. These data were accompanied by a corresponding PTH value of overnight incubation time, which significantly correlated with early time results. Conclusion: The values of PTH at 3 hours has favorable the rate of concordance of 94.1% and may be useful for prediction of hypocalcemia, and it responses to overnight incubation PTH values. Therefore, This method may be an attractive alternative to proper treatment to stop symptom revelation by giving a calcium agent to the patient.

  • PDF