• Title/Summary/Keyword: 민감도 측정

Search Result 1,700, Processing Time 0.035 seconds

Study on the Adaption Technique for Detection of Termites using Microwave (극초단파(Microwave)를 이용한 흰개미 탐지기술 적용연구)

  • Kim, Dae-Woon;Jeong, Seon-Hye;Lee, Sang-Hwan;Chung, Yong-Jae
    • Journal of Conservation Science
    • /
    • v.26 no.1
    • /
    • pp.77-83
    • /
    • 2010
  • The damage from the underground termite cannot be discovered with peculiar appearance of building but hollow phenomenon will occur. But there is no case in Korea as a non-destructive measurement of termite activation. Therefore, this research constructs non-destructive diagnostic techniques for wooden cultural properties using microwave detector (Termatrac, Australia). Result of maximun distance were measured 16cm (Pine tree, sensitivity 5, 6), 17cm (Zelkova and Douglas fir, sensitivity 5, 6). These results are expected that can be applied in the field. Result of field test using microwave detector, 33.8% of the wooden cultural properties were damaged by termites, and until now 7.8% (18 buildings) are being damaged in nationwide (total 231 buildings). Based on the above results, microwave detector will be able to be utilized effectively for detecting termite, preventing intrusion in wooden structure, and making full use of monitoring system periodically. In addition, it could be of great worth in preventing insect and microorganism in wooden structure.

A Experimental Study on the Depth of Scour to Formula Estimated of the Pattern Pier (원형 교각의 세굴심 산정식 개발에 대한 실험적 연구)

  • Baek, Kyung-Won;Park, Soo-Jin;Lee, Yeong-Seop;Choi, Han-Kuy
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • This study was intended to compare and evaluate the value obtained from the existing formula for calculating the depth of scour and the valey from experimental model through the investigation of hydraulic characteristics and pier data in the area of rivers at Gangwon Province, and the sensitivity analysis, which is a statistical method, of the elements affecting the scour of the pier was carried out. As a result, a deviation between the values of existing formulas and experimental model reached about 1.09%$^{\circ}$63.98%, indicating that existing formula was found not to be appropriate at the rivers in Gangwon Province. A sensitivity analysis was carried out based on value obtained from experimental model and consequently, the elements affecting the scour were size of pier accounting for 64% and water depth accounting for 36%. Finally, a formula for calculating the scour of the pattern piers at the rivers in Gangwon Province was developed using the regression analysis.

A Novel Luminance Adaptation Effect Model in Pixel Intensity Domain for Image Quality Assessment: Theory and Application (영상 화질 측정을 위한 픽셀 강도 영역의 새로운 광적응 효과 모델: 이론 및 적용)

  • Bae, Sung-Ho;Kim, Munchurl
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2015.07a
    • /
    • pp.78-80
    • /
    • 2015
  • 광적응(Luminance Adaptation; LA) 효과는 영상의 배경 밝기에 따른 왜곡에 대한 시각 인지 민감도가 달라지는 특성을 의미한다. 기존 영상 화질 측정(Image Quality Assessment; IQA) 방법들은 베버의 법칙(Weber' s law) 모델을 이용하여 LA 효과를 IQA 방법에 반영해왔다. 그러나, 이러한 IQA 방법들에 있어서 베버의 법칙 기반 LA 효과 모델은 다음 두 가지 이유로 부정확하게 동작한다: (i) 전통적인 베버의 법칙 모델은 실제 광도(luminance)에 대한 인지 민감도 응답값을 정확히 반영할 수 없다는 것이 밝혀졌다, (ii) 대부분 IQA 방법들은 픽셀 강도 영역에서 계산되지만, 베버의 법칙과 같은 LA 효과 모델들은 광도 영역에서 개발되었다. 따라서 광도와 픽셀 강도간 비선형 관계로 인해 IQA 방법에 반영된 베버의 법칙 기반 LA 효과 모델들은 부정확하게 동작한다. 이 문제를 해결하기 위해, 본 논문에서 처음으로 픽셀 강도 영역에서의 LA 모델을 이론적으로 유도한다. 본 논문에서 제안하는 픽셀 강도 영역에서의 LA 효과 모델은 감마 교정 함수(Gamma correction function)와 광도 영역에서의 LA 효과 모델인 제곱-법칙(power-law) 모델을 기반으로 하는 테일러 급수 확장 근사화를 통해 유도된다. 제안하는 픽셀 강도 영역 LA 효과 모델의 효과를 검증하기 위해, 제안하는 LA 효과 모델을 PSNR 에 도입하여 광범위한 실험을 수행한다. 실험 결과, 제안하는 LA 효과 모델 기반 PSNR 은 PSNR 및 베버의 법칙 기반 PSNR 대비 괄목할 만한 주관적 화질 예측 성능 향상을 보였다.

  • PDF

Characteristic Changes Observation of N-isopropylacrylamide Phantom by Repeated Ultrasound Irradiation (초음파 반복 조사에 따른 NIPAM 팬텀의 특성 변화 관찰)

  • Kim, Ju-Young;Kim, Jae-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.509-513
    • /
    • 2015
  • In this study, we evaluated the thermal denaturation characteristics of reusable NIPAM tissue mimicking (TM) Phantom by measuring the thermal sensitivity. And the changes of acoustic characteristic and thermal denaturation shape in NIPAM TM phantom according to the number of re-use time and re-use period were observed. With the result, as the sonication time is increased, the sound velocity of NIPAM phantom was decreased by 100 m/s and the attenuation was increased slightly. However, the changes according to the re-use period was not observed. In the thermal denaturation shape and size observation by ultrasound sonicaton, the remarkable changes have not been confirmed. With the result of this study, NIPAM Phantom was considered appropriate to evaluate and predict the effect of therapeutic ultrasound by in repeated sonication test.

Identification of Structural Defects in Rail Fastening Systems Using Flexural Wave Propagation (굽힘파 전파 특성을 이용한 레일체결장치의 구조 결함 진단)

  • Park, Jeongwon;Park, Junhong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.38-43
    • /
    • 2014
  • An experimental method based on flexural wave propagation is proposed for identification of structural damage in rail fastening systems. The vibration of a rail clamped and supported by viscoelastic pads is significantly influenced by dynamic support properties. Formation of a defect in the rail fastening system induces changes in the flexural wave propagation characteristics owning to the discontinuity in the structural properties. In this study, frequency-dependent support stiffness was measured to monitor this change by a transfer function method. The sensitivity of wave propagation on the defect was measured from the potential energy stored in a continuously supported rail. Further, the damage index was defined as a correlation coefficient between the change in the support stiffness and the sensitivity. The defect location was identified from the calculated damage index.

Verification of Optimum Degaussing Technique through the Mock-up Test of a Ship (축소 함정을 이용한 최적 소자기법 검증)

  • Kim, Dong-Wook;Choi, Nak-Sun;Kim, Dong-Hun;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.4
    • /
    • pp.107-113
    • /
    • 2014
  • In this paper, a optimum degaussing technique, which can minimize an underwater magnetic field anomaly generated by the ferromagnetic hull, was verified through the mock-up test of a ship. To predict degaussing field signals due to the degaussing coils installed in a ship, individual coil effects were measured. Exploiting the linearity of coil effects and analytical sensitivity formula, optimum degaussing current values fed to individual coils were decided. To identify degaussing performance of the proposed method, the obtained degaussing currents were applied to the coils. Then the field anomaly signals were measured and analyzed before and after degaussing. Experimental results show the magnitude of the field signal after degaussing is reduced up to 95% of that before degaussing.

포항 분지의 제3기 장기층군산 규화목에 의한 고환경 해석

  • Park, No-Tae;Kim, Jong-Heon
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.101-102
    • /
    • 2010
  • 규화목은 목본식물의 2차목부가 화석화된 것으로 화석화 과정에서 여러 종류의 무기물이 세포를 치환하거나 세포의 내강 또는 간극에 침투하여 고화된 것이다. 이 과정에서 목재의 해부학적 구조가 잘 보존되는 경우가 많고 이를 통해 목재의 수종을 비교적 정확히 동정할 수 있을 뿐만 아니라 과거 환경에 대한 정보를 얻을 수 있다. 목재는 유관속 형성층에 의해 매년 새롭게 형성되어 축적되며 형성된 조직은 성장하는 당해 기후변화를 반영하게 된다. 따라서 화석목재를 통해 과거 기후조건을 복원할 수 있는 정보를 얻을 수 있는 경우도 많다). 본 연구는 포항 분지의 신제3기 마이오세 장기층군에서 채집한 규화목의 조직과 나이테 분석을 통해 고환경을 해석한 것이다. 장기층군에서 채집한 15개의 규화목 표본 중 나이테가 잘 나타나는 5개 표본에서 나이테를 분석하고 그중 조직이 잘 보존된 1개의 표본에 대해 목재해부학적 연구를 수행하였다. 나무가 성장함에 따라 나타나는 나이테의 폭은 환경적 요인 등으로 매년 일정하지 않다. 이런 인접연륜간의 연륜변동성을 알아보기 위해 연륜연대학(Dendrochronology)에서 널리 사용되는 평균민감도 측정 방법을 사용하였다. 평균민감도는 연륜변동이 어느 정도있느냐를 알아보는 것으로 인접한 연륜들 사이의 차이를 측정하여 인접연륜간 연륜변동성을 나타낸다. 평균민감도 값이 크면 연륜폭 변동이 크다는 것을 의미하며 나무가 자라는 당시 환경인자의 변화량이 컸다고 해석할 수 있다. 조직이 잘 보존된 1개의 표본은 목재해부학적 특징상 느릅나무과(Ulmaceae) 느릅나무속(Ulmus)으로 동정되었다. 또한 5개 표본의 나이테를 분석한 결과 평균민감도는 0.34~0.41 범위를 나타내며 전체 평균은 0.37의 값을 갖는 것으로 나타났다. 이것은 규화목 생성 당시 환경이 온대기후를 지시하며, 물 공급이 매년 계절적인 제한을 받았거나 다양한 변화가 있어 계절적으로 강수량 변화가 있었음을 지시한다.

  • PDF

Characteristic Evaluation of Mercury lodide Film for Fluoroscopy Application (Fluoroscopy 적용을 위한 Mercuric lodide film 특성 평가)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Hoo;Yoon, Kyoung-Jun;Kang, Hyun-Gyu;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.494-497
    • /
    • 2004
  • 본 연구는 방사선 영상센서 적용을 위한 $HgI_2$ 필름의 특성 평가에 관한 것으로서 X-선 조사조건별 인가전압에 따른 검출신호 특성을 조사하였다. 기존의 $HgI_2$ 검출기의 경우 신호량이 크다는 장점이 있으나 노이즈의 양이 크다. 이에 대한 해결책으로 보호층을 삽입하나 이 경우 X-선 조사에 따른 시간 응답 특성이 있어서 전하트랩현상(tailing effect)에 의한 영향이 크게 존재하였다. 따라서 본 논문에서는 이러한 문제점을 해결하고자 보호층으로써 a-Se 을 삽입하여 기존의 $HgI_2$ 검출기에서 사용되어지는 parlyene이 삽입된 검출기와 전기적 특성을 측정, 비교해보고자 한다. 제작방식으로는 대면적 제작이 용이한 스크린 프린팅 방식을 이용하여 두께 $140\;{\mu}m$$3\;cm\;{\times}\;2\;cm$ 면적으로 제조하였다. 측정결과, a-Se을 보호층으로 사용한 $HgI_2$ 필름이 민감도는 거의 비슷하나 누설전류가 안정화 되는데 걸리는 감소시간(decay time)이 parlyene을 사용한 구조에 비해 훨씬 낮았다. 또한 X선에 대한 민감도는 기존의 a-Se에 비해 월등히 높아 적은 방사선 조사량(radiation dose)에서도 신호검출이 가능하여 저선량이 요구되는 방사선 투시촬영(digital fluoroscopy) 적용에 유용할 것으로 기대된다.

  • PDF

A Study on the Acoustic Analysis Method of the External Ear Canal Using DICOM Images (DICOM 영상을 이용한 외이도 음향해석 방법에 관한 연구)

  • Kim, Hyeong-Gyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.73-79
    • /
    • 2019
  • This study simulated external ear canal modeling with different external ear canal lengths, vertical flexion angles, and inner/outer diameter ratios using digital imaging and communications in medicine(DICOM) of the head temporal region and measured the acoustic sensitivity. The experiment was performed by increasing the audible frequency for humans by 200 Hz and expressing the frequency constantly transmitted at 1 Pa as the eardrum acoustic volume and presented the measurements by linear and quadratic curve regression analysis. The results showed that the longer the external ear canal length and the higher the ratio of the outer/inner diameter, the faster the acoustic response at lower frequencies. The acoustic sensitivity correlation of the meta-model using regression analysis showed a 77% influence by the external ear canal length and 5% by the external/internal diameter ratio, while the vertical flexion angle did not show a significant relationship. This showed that auditory acoustic sensitivity of humans is a factor that reacts faster at a low frequency when the external ear canal length is longer and when the difference between the outer and inner diameter is higher.

Development of Single Channel ECG Signal Based Biometrics System (단채널 심전도 기반 바이오인식 시스템 개발)

  • Gang, Gyeong-Woo;Min, Chul-Hong;Kim, Tae-Seon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.49 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • In general, currently developed ECG(electrocardiogram) based biometrics approaches are not suitable for real market applications since they require high cost ECG monitoring device and their measurement methods showed poor usability. In this paper, we developed lead I signal based biometrics system using special purpose ECG measurement hardware. To guarantee signal quality for biometrics from various signal measurement environment in our ordinary life, several filters are applied. In addition, to enhance usability, only two skin on electrodes without reference point are used for measurement. Lead I signals of seventeen candidates are measured from developed hardware and features are extracted. Extracted features are applied to support vector machine (SVM) pattern classifier for biometrics, and the experimental results showed 98.59% of sensitivity (SN) and 97.21% of accuracy (ACC). Compare to conventional ECG biometrics approaches, proposed system showed enhanced usability with low-cost measurement hardware.