Abstract
In this paper, a optimum degaussing technique, which can minimize an underwater magnetic field anomaly generated by the ferromagnetic hull, was verified through the mock-up test of a ship. To predict degaussing field signals due to the degaussing coils installed in a ship, individual coil effects were measured. Exploiting the linearity of coil effects and analytical sensitivity formula, optimum degaussing current values fed to individual coils were decided. To identify degaussing performance of the proposed method, the obtained degaussing currents were applied to the coils. Then the field anomaly signals were measured and analyzed before and after degaussing. Experimental results show the magnitude of the field signal after degaussing is reduced up to 95% of that before degaussing.
본 논문에서는 축소 함정을 이용한 소자시험을 통하여 강자성체 선체에 의해 발생하는 수중 자기장 왜곡신호를 최소화할 수 있는 최적 소자기법의 타당성을 검증하였다. 소자코일에 의해 발생하는 소자 자기장 신호를 예측하기 위하여, 축소 함정 내에 설치된 개별 소자코일에 대한 코일효과를 측정하였다. 코일효과의 선형성과 해석적인 민감도 식을 기반으로 각 소자코일에 인가해야 할 최적 소자전류를 도출하였다. 확립된 최적 소자기법의 성능 검증을 위하여, 도출된 최적 소자전류를 축소 함정의 소자코일에 인가하여 발생하는 소자 전 후의 자기장 왜곡신호를 측정하고 분석하였다. 시험결과 소자 후 자기장 왜곡신호의 크기는 소자 전에 비해 95 % 정도 감소함을 확인하였다.