• Title/Summary/Keyword: 물리 흡수

Search Result 590, Processing Time 0.032 seconds

Characteristics of Tissue Dose of High Dose Rate Ir-192 Source Substitution for Co-60 Brachytherapy Source (코발트-60 선원 대체용 고선량률 Ir-192 선원의 조직선량특성)

  • 최태진;이호준;김옥배
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • To achieve the 2D dose distribution around the designed high dose rate Ir-192 source substitution for Co-60 brachytherapy source, we determined the exposure rate constant and tissue attenuation factors as a large depth as a 20 cm from source center. The exposure rate constant is used for apparent activity in designed source with self-absorption and encapsulation steel wall. The tissue dose delivered from the 4401 segments of 2.5 mm in a diameter and 2.5 mm height of disk-type source layer. In the experiments, the tissue attenuation factors include the tissue attenuation and multiple scattering in a medium surrounding the source. The fitted the polynomial regression with 4th order for the tissue attenuation factors are very closed to the experimental measurement data within ${\pm}$1% discrepancy. The Meisberger's constant showed the large uncertainty in large distance from source. The exposure rate constant 4.69 Rcm$^2$/mCi-hr was currently used for determination of apparent activity of source and air kerma strength was obtained 0.973 for tissue absorbed dose from the energy spectrum of Ir-192 source. In our experiments with designed high dose rate brachytherapy source, the apparent activity of Ir-192 source was delivered from the 54.6 % of actual physical source activity through the self-absorption and encapsulation wall attenuations. This paper provides the 2-dimensional dose tabulation from unit apparent activity in a water medium for dose planning includes the multiple scattering, source anisotropy effect and geometric factors.

  • PDF

Effect of Press Temperature and Time on Physical Properties of Larch Particleboard (압체온도(壓締温度)와 시간(時間)이 낙엽송(落葉松) 파티클 보오드의 물리적(物理的) 특성(特性)에 미치는 영향(影響))

  • Lee, Phil Woo;Chung, Gyun
    • Journal of Korean Society of Forest Science
    • /
    • v.63 no.1
    • /
    • pp.12-20
    • /
    • 1984
  • This research was performed to estimate the properties of particleboard based on the press time and temperature which was made of chip of larch that grows in Korea. The results in this study were as follows: 1) Even though the chips, 1:1-35 ratio between length and thickness, are relatively bad condition, the surface smoothness that can easily spread the adhesive evenly and thoroughly and bonding ability of chips can give proper physical properties. 2) It shows more mechanical properties at the press time of 10 min. in MOR (Modulus of Rupture), MOE (Modulus of Elasticity) and SHA (Screw Holding Ability). 3) It is not significant according to the press time 20 min. in MOR, IBS (Internal Bonding Strength) and SHA, for the reciprocal actions between the accelerating aging effect of chip and the softening effect of adhesion are occured. 4) IBS is rising according to the increasing temp at the press time of 10 min. Because it needs to transfer the plate heat to make the proper hardening temp. In the layer. 5) The heat treatment effects have greatly influenced the stahility of dimension by falling the absorption, anisotropy and inhomegenity. As a result of these the values of thickness and linear expansion ratio were respectively dropped by the increase of press temp and the time and so did absorption.

  • PDF

Effects of the Antiestrogen on Morphologic Changes of efferent ductules of the Adult Male Mouse (항에스트로겐이 성체 수컷 마우스 수출소관의 형태적 변화에 미치는 효과)

  • Kim, Myung-Hoon
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.190-197
    • /
    • 2003
  • This study was designed to investigate the function of estrogen in related with the effects of the antiestrogen on morphologic changes of efferent ductules of the adult male mouse. Estrogen is synthesized in the male reproductive system and is found in high concentrations in rete and seminal fluids. Adult male mice, 30 days old, were injected subcutaneously with ICI(5mg/mouse) once per week for 8 weeks. Tissues were fixed by vascular perfusion on days 8, 10, 12, 14, 16, 25 and 59 post-treatment. The lumen of efferent ductules began to dilate from the day 8 and continued to the day 59 post-treatment. Epithelial cell height in the efferent ductules of the treated mice decreased all the time periods, compared to the control. Cell height in proximal region of the efferent ductules in the treated groups decreased most by 38%. Supranuclear cytoplasmic height in epithelial cell of the ducts also showed the decrease of 46%, 39% and 33% in proximal, conus and common regions in the treated groups, respectively. ICI 182,780 treatment in the male mouse reproduced a similar morphological abnormalities that were observed in the efferent ductules of the ${\alpha}ERKO$ mouse.

  • PDF

Marine Environments and Production of Laver Farm at Aphae-do Based on Water Quality and Phytoplankton Community (수질환경과 식물플랑크톤 군집 변화에 의한 압해도 김 양식장의 해양환경과 생산)

  • Yoon, Yang Ho
    • Korean Journal of Environmental Biology
    • /
    • v.32 no.3
    • /
    • pp.159-167
    • /
    • 2014
  • In this study, I examined the water quality and phytoplankton community in aquaculture laver farm in the southwest part of Aphae-do, South Korea, based on the young leaf stage, middle leaf stage, and adult leaf stage of laver thallus from October, 2013 to January, 2014. It was observed that the Aphae laver farm, as located in shallow waters, was found to have a serious resuspsension of the surface sediments due to physical disturbance caused by winds and tidal mixing. Such a resuspension of surface sediments coupled with nutrients supply obstructs light penetration into the sea for its huge amount of total suspended matters. As a result for this reason, it was viewed toimpedthe growth of phytoplankton was impeded as it also competes with laver to absorb the same kinds of nutrients as laver does during the laver growth period in winter. Such elements of the marine environment in Aphae laver farm are in contrast with the environment of Japan, where nutrients including dissolved inorganic nitrogen, in particular, are insufficient to cause the recent laver bad harvest, discoloration and quality degradation while large diatoms, with their higher nutrients absorption efficiency than laver, generate winter red tide. In other words, an important factor to maintain the high laver production in the southern parts of West Sea of Korea was found to be the marine environment of its laver farms where large diatoms are prevented from growing due to nutrients supply and dense seston weights from resuspended matters by physical disturbances.

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

A study on the dose distribution for total-body & hemibody irradiation using clinical photon beams (광자선을 이용한 전신 및 반신조사의 선량분포에 관한 고찰)

  • 김진기;권형철;김정수;오영기;김기환;신교철;김정홍;박충기;정동혁
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.147-153
    • /
    • 2001
  • We have discussed that the total body irradiation(TBI) dose distribution of 6 and 10 MV photon beams, also differences between calculation dose use of compensator sheet and measurements in humanoid phantom. Total body irradiation and hemi-body irradiation(HBI) can be effectively performed when uniformity of dose distribution is estabilished. The method of TBI and HBI dosimatry requires special considerations related to technique, long distance and very large field, machine parameter, patient positioning. TBI and HBI with megavoltage photon beams requires basic dosimatric data which have to be measured directly or derived from the standard beam data. The semiconductor detector and ion chamber were positioned at a dmax depth, mid depth, and its specific ratio was determined using a scanning data by RFA-7 3-dimensional water phantom and solid phantom. The effective source axis distance 380 cm, the field size from 120 cm to 152 cm, isodose distributions were analyzed as a function of the thickness in phantom. Also, have discussed that the measurement of basic data for clinical photon beams for dosage calculations, data calculation sheet and the use of tissue compensation to improve dose uniformity. We have improved a dose uniformity in the TBI and HBI method.

  • PDF

Spray-dried powder preparation of pumpkin sweet potato hydrolysates and its physicochemical properties (호박고구마 효소 분해물의 분무건조 분말 제조 및 물리화학적 품질특성)

  • Lee, Dae-Hoon;Jang, Jong-Hyun;Hong, Joo-Heon
    • Food Science and Preservation
    • /
    • v.24 no.2
    • /
    • pp.246-253
    • /
    • 2017
  • This study was conducted prepare spray-dried powder using pumpkin sweet potato hydrolysates and examine the physicochemical properties of the powder. The insoluble dietary fiber and soluble dietary fiber of the pumpkin sweet potato treated by enzyme were 4.17% and 2.07%, respectively. The spray-dried pumpkin sweet potato hydrolysates was manufactured via spray-drying with different forming agents: i.e., pectin 0.1%, 0.5%, 1%, and 2.0%. The moisture contents and total starches of the spray-dried powders were approximately 1.68-2.46 and 45.32-46.51%, respectively. The color of the L and a value decreased, and that of the b and ${\Delta}E$ value increased. The particle size and outer topology of the spray-dried powders were $37.17-42.32{\mu}m$, and its shape was generally globular. The water absorption index of the spray-dried powder (1.74-1.91) was lower than that of the freeze-dried powder (2.15). The water solubility index of the spray-dried powder, 80.75-87.61%, was higher than that of the freeze-dried powder (70.47%). The adhesion values of spray-dried powder to epithelial HT-29 cells were 2.66-6.18% of the initial cell counts, whereas freeze-dried powder showed lower adhesive ability (1.79%). The in vitro human digestibility in the spray-dried powder was 70.09% which is very effective in digestion.

Physicochemical Characteristics of Korean Folk Sojues (전통민속소주의 물리화학적 특성)

  • Lee, Dong-Sun;Park, Hye-Seong;Kim, Kun;Lee, Taik-Soo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.649-654
    • /
    • 1994
  • In order to provide a quality index of Korean folk sojues, physicochemical properties of Korean folk sojues (Andong soju, Moonbaesul, Leekangju, Jindo Hongju, Chebiwon soju, Yethyang (rice) and Yethyang (barley)), Paekrosul, Chinese kaoliangchiews (Moutaichiew, Ergoutoutiu, Chuyehchingchiew, Zhikukaoliangchiew and Paigal), Japanese Senbatanuki shochu and two whiskies were determined. The pH of sojues ($3.43{\sim}5.85$) were mainly influenced by total acidity which was described as acetic acid. The conductivities of Paekrosul and Leekangju showed relatively high value of $246\;and\;122.7{\mu}S/cm$, respectively. Korean folk sojues and Paekrosul showed maximum absorption at 274 or $278{\sim}280nm$ in the spectrometric study. We performed principal components analysis (PCA) of physicochemical properties and spectrometric data to extract representative characteristics and to compare the similarity or the dissimilarity. The PCA plot showed the distinguished cluster of Korean folk sojues comparing with Chinese kaoliangchiew or Paekrosul etc.

  • PDF

Physical Characterizations and In Vitro Skin Permeation of Elastic Liposomes for Transdermal Delivery of Polygonum aviculare L. Extract (마디풀 추출물의 경피 전달을 위한 탄성 리포좀의 물리적 특성 및 In Vitro 피부 투과 연구)

  • Han, Saet Byeol;Kwon, Soon Sik;Jeong, Yoo Min;Kong, Bong Ju;Yu, Eun Ryeong;Park, Soo Nam
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.694-701
    • /
    • 2014
  • In this study, Polygomun aviculare L. (P. aviculare L.) extract loaded elastic liposomes (ELPs) were investigated to enhance the transdermal delivery of P. aviculare L. extract composed of various flavonoids. ELPs were composed of egg phospholipids (PC) and edge activator ($Tego^{(R)}$ care 450) and the physical properties and in vitro permeation studies of ELPs were performed. Particle size ranged from 148.1 to 262.2 nm and deformability index was recorded as 11.5~25.4. Loading efficiency was from 53.1 to 66.3%. In vitro skin permeation studies using Franz diffusion cell demonstrated that ELP-4 having ratio of 85:15 for PC to $Tego^{(R)}$ care 450 exhibited the higher skin permeability than ELP-1, the general liposome without $Tego^{(R)}$ care 450. It was visually seen by fluorescence image restoration microscopy. The findings suggest that ELP-4 selected as the optimal formulation could be used as useful formulation for transdermal delivery of the extract.

Study on the Small Fields Dosimetry for High Energy Photon-based Radiation Therapy (고에너지 광자선을 이용한 방사선 치료 시 소조사면에서의 흡수선량평가에 관한 연구)

  • Jeong, Hae-Sun;Han, Young-Yih;Kum, O-Yeon;Kim, Chan-Hyeong
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.290-297
    • /
    • 2009
  • In case of radiation treatment using small field high-energy photon beams, an accurate dosimetry is a challenging task because of dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons, and non-uniformity between the detector and the phantom materials. In this study, the absorbed dose in the phantom was measured by using an ion chamber and a diode detector widely used in clinics. $GAFCHROMIC^{(R)}$ EBT films composed of water equivalent materials was also evaluated as a small field detector and compared with ionchamber and diode detectors. The output factors at 10 cm depth of a solid phantom located 100 cm from the 6 MV linear accelerator (Varian, 6 EX) source were measured for 6 field sizes ($5{\times}5\;cm^2$, $2{\times}2\;cm^2$, $1.5{\times}1.5\;cm^2$, $1{\times}1\;cm^2$, $0.7{\times}0.7\;cm^2$ and $0.5{\times}0.5\;cm^2$). As a result, from $5{\times}5\;cm^2$ to $1.5{\times}1.5\;cm^2$ field sizes, absorbed doses from three detectors were accurately identified within 1%. Wheres, the ion chamber underestimated dose compared to other detectors in the field sizes less than $1{\times}1\;cm^2$. In order to correct the observed underestimation, a convolution method was employed to eliminate the volume averaging effect of an ion chamber. Finally, in $1{\times}1\;cm^2$ field the absorbed dose with a diode detector was about 3% higher than that with the EBT film while the dose with the ion chamber after volume correction was 1% lower. For $0.5{\times}0.5\;cm^2$ field, the dose with the diode detector was 1% larger than that with the EBT film while dose with volume corrected ionization chamber was 7% lower. In conclusion, the possibility of $GAFCHROMIC^{(R)}$ EBT film as an small field dosimeter was tested and further investigation will be proceed using Monte Calro simulation.

  • PDF