• Title/Summary/Keyword: 무자각

Search Result 27, Processing Time 0.021 seconds

A Design of Kidney Diseases Diagnosis Method Using Formant Frequency Bandwidth Extraction and Analysis (포먼트 주파수 대역폭 추출 및 분석을 이용한 신장 질환 진단 방법의 설계)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.10B
    • /
    • pp.1062-1069
    • /
    • 2009
  • The kidney diseases is a big social problem what is suffering sequela of metabolic syndrome due to obesity. Therefore, it is most important that early to take the appropriate action; it does not have symptoms Abnormalities of the kidney. With this, in mind, this paper wish to propose the method to can diagnosis by non self-consciousness, non-imprisonment, analgesia of kidney disease through the voice analysis. To configure the entire system is developed to combines the voice analysis, watching the face color and this paper is designed the method to diagnosis kidney disease based on labial. In this paper, organized each kidney disease patients and healthy people group and we would like to analyze, compare with output in experiment morphology analysis and numerical value analysis of voice information. Secondly, auscultation theory of Oriental medicine and linguistic, phonetics analyze out interrelation to extraction peculiar elements of kidney about voice deduction deduced relation of the first formants frequency. Such result of experimentation, deduced widely to be formed the first formants frequency bandwidth value of kidney patients group than normal group. Finally, diagnosing an kidney diseases in only labial sound, calculated about misdiagnosis probability.

Design a Portable Biomedical Signal Measuring System for U-Health (U-Health를 위한 휴대형 생체신호 측정 시스템 설계)

  • Lee, Han-Wook;Kim, Sung-Hoo;Jeong, Won-Geun;Lee, Ju-Won;Jang, Doo-Bong;Lee, Gun-Ki
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.1 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • U-Health is abbreviated from ubiquitous Health. Its final aim is "to improve the quality of life. To realize it, it is needed to generalize IT infrastructure such as the development of information-technology and construction of network. It is guaranteed to get medical care benefits unconsciously every time and everywhere based on this system. In this study, the environment of unconscious measurement was set up through ultra-violet instead of the existing Probe to wear with finger to follow this. TFT-LCD was included into module for display. U-Healthcare focused on the minimization and portable characteristic through the designed Zigbee communication module. Handled healthcare device was developed based on the U-Healthcare.

  • PDF

Growth Inhibition of Helicobacter pylori by Ingestion of Fermented Soybean Paste (된장 섭취에 의한 Helicobacter pylori의 생장 억제)

  • Kim, Hyung-Rak;Kim, Young-Hyu;Park, Seong-Chan;Kim, Mi-Sun;Baik, Keun-Sik;Cho, Hyun-Wook;Seong, Chi-Nam
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1695-1700
    • /
    • 2007
  • The aim of this study was to estimate the ingestion effect of fermented soybean paste on the growth inhibition of Helicobacter pylori. Anti-H. pylori effect of the aqueous extract of soybean paste and cell-free supernatant of the isolates from soybean paste were determined using agar diffusion method. Soybean paste and the isolates inhibited the growth of H. pylori. Effect of soybean paste ingestion was estimated using urea breath test against infected volunteers showing no symptom of gastric disease. When 10 g of soybean paste was ingested 3 times a day for 6 weeks, average value of $P={\Delta}^{13}C(T_1-T_0)$ decreased from P=58 to P=28. This result indicated that fermented soybean paste was effective to inhibit the growth of H. pylori in gastric tissue.

Home Health Care Service Using Routine Vital Sign Checkup and Electronic Health Questionnaires (주기적인 생리변수 측정과 전자건강설문을 이용한 재택건강관리서비스)

  • 박승훈;우응제;이광호;김종철
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.469-477
    • /
    • 2001
  • In this Paper. we describe a home health care service using electronic health questionnaires and routine checkup of vital signs Including ECG (Electrocardiography) , blood pressure. and SpO$_2$ (Oxygen Saturation) . This system is for patients at home with chronic diseases, discharged Patients, or any normal people for the Prevention of disease The service requires a home health care terminal and a PC with Interned connection installed at Patient home. The distance health care management center is equipped with a vital-sign and questionnaire interpreter as well as database, Web, and notification servers with UMS (Unified Messaging System). Participating Physician can access the servers at the center using a Web browser running on a PC available to them at any time. These components are linked together through various kinds of data and voice communication channels including PSTN (Public Switched Telephone Network) . CATV(Community Antenna TV) . Interned. and mobile communication network. Following the Physician's direction given to a Patient. he or she uses the home health care terminal to collect vital signs and fill out the questionnaire. When the terminal automatically transmits these data to the management center. the data interpreter and servers at the center process the information fo1lowing the Protocol implemented on the system. Physicians can retrieve and review data corresponding to their Patients and send back their diagnostic reports to the center. UMS at the center delivers the physician 's recommendation to the corresponding patient through the notification server. Patients can also reprieve and review their own records as well as diagnostic reports from physicians. The system Provides a new way of collecting diagnostic information and delivering doctor's recommendation to patients at home for their health management. Future works are needed in the development of new technology for measurements and interpretations of various vital signs .

  • PDF

Study of Multi-Resident Location Tracking Service Model Based on Context Information (상황정보 기반의 다중 거주자 위치 추적 서비스에 관한 연구)

  • Won, Jeong Chang;Man, Ko Kwang;Chong, Joo Su
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.3 no.5
    • /
    • pp.141-150
    • /
    • 2014
  • In recent years, because of the development of ubiquitous technology in healthcare research is actively progress. Especially, healthcare service area is change to home for the elderly or patients from hospital. The technology to identify residents in a home is crucial for smart home application services. However, existing researches for resident identification have several problems. In this case, residents are needed to attach of various sensors on their body. Also relating private life, it is difficult to apply to resident's environment. In this paper, we used constraint-free sensor and unconscious sensor to solve these problems and we limited using of sensor and indoor environment in the way of working economical price systems. The way of multi-resident identification using only these limited sensors, we selected elements of personal identifications and suggested the methods in giving the weight to apply these elements to systems. And we designed the SABA mechanism to tract their location and identify the residents. It mechanism can distinguish residents through the sensors located each space and can finally identify them by using the records of their behaviors occurred before. And we applied the mechanism designed for applications to approve this location tracking system. We verified to the location tracking system performance according to the scenario.

HRV Evaluation under Stress Condition by Using Patch Type Bipolar Heart Activity Monitoring System (패치형 바이폴라 심장활동 모니터링 시스템을 이용한 스트레스 상태의 HRV 평가)

  • Yang, Heui-Kyung;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Lee, Kang-Hwi;Choi, Hee-Jung
    • Science of Emotion and Sensibility
    • /
    • v.12 no.2
    • /
    • pp.161-168
    • /
    • 2009
  • In this study, we have developed the patch type HAMS (Heart Activity Monitoring System) which is non-restricted, non-awarable and non-invasive. The module using wireless telecommunication to receive the ECG (electrocardiogram) signal at the computer has mobility which it easily monitors the heart activity of subjects in no time for long term at any time and places. We developed the small patch type electrode which can be attached on the chest. Also the reliability and moving artifact of ECG signal measured by this electrode have been verified. Using HAMS, we measured the HRV (Heart Rate Variability) parameters, the questionnaire evaluation for anxiety and stress and the amount of stress hormone (cotisol) to evaluate the stress effect in HRV on the same subject. As a result of comparing the values under non stressed and stressed condition, there was significant difference on many parameters. And the parameter highly related with stress on Pearson's Correlation Coefficient has been examined. These show that using HAMS is able to evaluate the function of autonomic nervous system. Therefore, we can predict heart problem in daily life by using HAMS. Also we expect that this module can be applied for more application as health monitoring system.

  • PDF

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF