• Title/Summary/Keyword: 무근 콘크리트

Search Result 92, Processing Time 0.022 seconds

Experimental and Analytical studies on Failure Behavior of Stud Shear Connectors in CFT Structures (CFT 구조에 적용된 스터드 전단연결재의 파괴 거동에 대한 실험 및 해석적 연구)

  • Lee, Sangyoon
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.400-412
    • /
    • 2013
  • For the composite behavior of steel tube and inner concrete, the shear connectors should be applied to the CFT structures. However, the present design codes don't provide the design criteria that can be applied on shear connectors in the CFT structures typically filled with plain concrete. This study has been carried out to propose design criteria (shear strength and resistance factor) for the stud shear connectors in CFT structures. Experimental tests using the push-out specimens with the plain concrete blocks and finite element analysis were conducted for the purpose of verifying the main failure mode to propose the shear strength of studs in CFT structures. From the results of this study, the main failure mode of studs in CFT structures is splitting crack of concrete and this failure mode reduces shear strength of studs in CFT structures relatively to those embedded in RC blocks.

The Present Condition and Prospects of Concrete Products in Japan (일본의 콘크리트 제품 현황과 전망)

  • 복택공부;삼정아일;김무한
    • Magazine of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.32-40
    • /
    • 2002
  • 콘크리트 제품은 프리캐스트 콘크리트의 일종이며, 일반적으로 공장에서 생산되는 무근 콘크리트, 철근 콘크리트 및 프리스트레스트 콘크리트 부재를 말한다. 본고는 일본에서의 콘크리트 제품에 대한 기술적 동향을 소개하는 것으로서 일본에서는 콘크리트제품마다 관계자에 의해 이루어지기 때문에 이를 체계적으로 기술하는 것은 곤란하며 되도록 광범위한 정보를 전달하고자 하지만 필자들의 지식부족으로 소개할 수 없는 부분도 많이 존재하는 점에 대해 양해를 구하고자 한다. 또한 신기술의 소개에 있어서 그 기술이 어느 정도 새로운 것인지를 나타내기 위하여 현재에 이르기까지의 경위에 대해서도 약간 다루기로 한다.(중략)

The Control Methods of Crack on Concrete with Fiber reinforced and Finishing (섬유종류 및 마감방법에 따른 무근콘크리트의 균열제어 방법)

  • Lee, Tae-Gyu;Kim, Gyu-Yong;Kang, Yeon-Woo;Kim, Soon-Mook;Kim, Soo-Bong;Jung, Jae-Yung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.260-261
    • /
    • 2014
  • When press concrete with high W/B was hardened, it should consider a crack to make stress by drying shrinkage. For control of crack, wire-mesh used to reinforce concrete in site. Actually, it reported failure case in lack of quality control. This study conducted experiment to apply fiber reinforced press concrete. it was evaluated on fresh property, compressive strength and shrinkage crack of press concrete with fiber.

  • PDF

Performance Evaluation of Concrete using Performance Improving-type Polycarboxylic acid-based Admixture (성능개선형 폴리카르본산계 혼화제를 사용한 콘크리트의 성능평가에 관한 실험적 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae;Gong, Min-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.5
    • /
    • pp.445-451
    • /
    • 2017
  • Because of the supply-demand problem of aggregate, recently, the construction sites using 100% crushed sand are increasing and the use of low quality aggregate such as farmland sand is increasing too. When the low quality aggregate is used, the various quality defect of concrete such as the strength reduction, the increase of shrinkage and bleeding can be occurred. Therefore, in this study, the performance improvement PC admixture was developed to minimize the quality defect of plain concrete of basement parking area, when the low quality aggregate was used at the plain concrete of basement parking area. The slump loss to elapsed time test, the compressive strength test, the bleeding test and the drying shrinkage test were carried out.

Experimental Evaluation on Structural Analysis of the Shear Key between Concrete-PE Modules (콘크리트-PE 부유체 모듈의 케이싱형 전단키 구조성능 실험평가)

  • Jeongsoo Kim;Yeon-Ju Jeong
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.545-553
    • /
    • 2023
  • Purpose: This study proposes a casing type of shear key to connect with floating breakwater modules composed of concrete and PE(Poly Ethylene), and evaluates the structural performance of the shear key. Method: According to Eurocode, extreme load tests of shear keys with several cross-sections were conducted. Result: The maximum shear resistance of the casing type is 1.5 times than those of the plain concrete type, and the use of the casing shear key leads to ductile behaviors after its peak shear resistance than the shear key made of reinforced concrete. Conclusion: The use of the proposed casing type of shear key will contributes to improve the safety of the shear connection between modular structures.

A study of Building Mix-Design and Construction Process to Reduce the Combined Deterioration of Plain Concrete. (옥상 무근콘크리트 복합열화 방지를 위한 시공 프로세스 구축 및 배합 설계에 관한 연구)

  • Kim, Dae-Geon;Lee, Woo-Geun;Kang, Ye-Jin;Yeo, Dong-Kyu;Kim, Do-Hun;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.85-86
    • /
    • 2018
  • In the case where the building's rooftop was laid without any foundation, the combined deterioration, such as the repetition of shrinkage and expansion caused by temperature changes, caused further cost generation and damage. To prevent this, the concrete mixing design and construction process shall be established to resist combined deterioration.

  • PDF

Study on plain concrete crack reduction characteristics by fiber type (섬유보강재 종류에 따른 무근콘크리트 균열저감 특성에 관한 연구)

  • Lee, Ji-Hwan;Yun, Chang-Yeon;Park, Gi-Hong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.178-179
    • /
    • 2022
  • This study evaluated the crack reduction characteristics of concrete by type of fiber reinforced concrete. As a result of the experiment, it was shown that the fluidity decreased due to the mixing of the fiber reinforcing material. The higher the amount of fiber reinforced material used, the higher the decrease in fluidity. It was confirmed that the tensile strength was improved by the mixing of the fiber reinforcing material. The selection of fiber reinforcement has a great influence on the crack reduction effect.

  • PDF

An Evaluation of Shear Strength of Plain HVFAC Concrete by Double Shear Test Method (2면전단시험법에 의한 무근 HVFAC 콘크리트의 전단강도 평가)

  • Lee, Hyung-Jib;Suh, Jeong-In;Yoo, Sung-Won
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.261-266
    • /
    • 2017
  • In this study, to determine the shear properties, experiments on the shear behavior of plain concrete with the high volume fly ash cement by double shear test were performed. Test parameters are fly ash content and concrete compressive strength. Experimental results show the tendency that the shear strength similarly increases with an increase in the compressive strength as is generally known. The concrete shear strength formula proposed in the concrete structural design code of KCI shows a similar tendency to the experimental results, and It is expected that the shear strength of the high volume fly ash cement concrete can be applied with the formula given in the concrete structural design code of KCI. When considering the fly ash content ratio, the shear strength of high volume fly ash cement concrete according to fly ash conctent ratio shows as having a far greater correlation than if it is not considered to fly ash content ratio. So, even though existing code can be appliable for non consideration of the fly ash content ratio, we proposed a formula that is much more relevant than that of concrete structural design code of KCI.

Application of Acoustic Emission for Assessing Deterioration in Reinforced Concrete Beams (철근 콘크리트 빔의 노화도 평가를 위한 음향방출 기술의 응용)

  • Yoon, Dong-Jin;Park, Phi-Lip;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.276-284
    • /
    • 2000
  • The acoustic emission (AE) behavior of reinforced concrete beams tested under flexural loading was investigated to characterize and identify the source of damage. This research was aimed at identifying the characteristic AE response associated with micro-crack development, localized crack propagation, corrosion, and debonding of the reinforcing steel. Concrete beams were prepared to isolate the damage mechanisms by using plain, notched-plain, reinforced, and corroded-reinforced specimens. The beams were tested using four-point cyclic step-loading. The AE response was analyzed to obtain key parameters such as the time history of AE events, the total number and rate of AE events, and the characteristic features of the waveform. Initial analysis of the AE signal has shown that a clear difference in the AE response is observed depending on the source of the damage. The Felicity ratio exhibited a correlation with the overall damage level, while the number of AE events during unloading can be an effective criterion to estimate the level of corrosion distress in reinforced concrete structures. Consequently, AE measurement characterization appears to provide a promising approach for estimating the level of deterioration in reinforced concrete structure.

  • PDF