• Title/Summary/Keyword: 맥동신호

Search Result 26, Processing Time 0.018 seconds

A study on non-invasive SaO$_2$ measurement algorithm to improve on effect of the motion artifact (동잡음의 영향을 개선한 비관혈식 산소포화도 측정 알고리즘에 대한 연구)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.101-107
    • /
    • 2000
  • Pulse oximetry is a non-invasive optical method which measures arterial oxygen saturation with two different wavelength. We can obtain the pulsating component of the arterial blood superimposed on DC level attenuated by venous blood, skin and other nonpulsatile components. This study is based on computing algorithm of oxygen saturation using the integral ratio of pulsatile components. In this algorithm, we used the half cycle of the pulsatile signal rely on arterial contraction. It's period is about 1/4 in 1 cycle. In the result, Our algorithm with 1/4 period of 1 cycle is similar to existing model. Because of removal that A part have low amplitude and possession in long term from calculating, the effect of the motion-artifact is decrease.

  • PDF

Noise source identification of a pulse combustion burner by digital signal processing techniques (디지탈 신호처리 기법을 이용한 맥동연소기의 소음원 규명에 관한 연구)

  • 송척기;조정길;이관수;오재응
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.9-14
    • /
    • 1990
  • 맥동 연소기는 기존의 연속 연소식 연소기에 비하여 높은 열효율, 소형화, 연소과정의 개선, 시동후 점화플러그 및 송풍팬의 불필요, 자력 배기와 장시 간 안전 운전등의 장점들로 인하여 최근 연구대상으로서 주목을 받고 있다. 맥동연소 현상은 1800년경부터 알려졌음에도 불구하고 기본적인 연소메카니 즘 및 기본동작 원리에 대한 미비점 및 높은 소음 등으로 인하여 종래의 연 구는 거의 실험을 통하여 이루어 졌으며 이러한 것들이 현재까지도 맥동 연 소기의 발전에 걸림돌이 되고 있다. 맥동 연소기가 산업용 및 가정용 열기기 로서 사용되기 위하여 진동과 소음의 감소에 대한 엄격한 요구를 만족하지 않으면 안된다. 따라서, 그에 대한 효과적인 방지 설계를 하기 위하여 진동 원과 소음원이 어느 부위에서 전달되어 오는지를 파악하는 것이 중요하다.. 본 연구에서는 맥동연소기의 소음원을 규명하기 위하여 종래에 사용되어 온 주파수 응답함수법과 소음원간에 강한 상관관계가 존재하는 경우에 사용되 는 기여도함수법을 이용하여 다차원 스펙트럼해석법에 의하여 입출력간의 기여관계를 규명하였다.

  • PDF

Enhancement of Signal to Noise Ratio for High Frequency Square-Wave Injection Sensorless Drive with Regulation of Induced High Frequency Current Ripple (고주파 전류 맥동 제어를 통한 신호 주입 센서리스 방법의 신호 대 잡음 비(SNR) 개선)

  • Kim, DongOuk;Kwon, Yong-Cheol;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.167-168
    • /
    • 2013
  • 신호 주입 센서리스 구동 시, 인버터의 비선형성으로 인한 주입 전압 왜곡현상은 전류 신호 정보의 SNR을 떨어뜨리게 된다. 이로 인하여 회전자 위치를 추정하는 과정에서 오차가 발생하는 문제점이 발생한다. 본 논문에서는 인버터의 비선형성이 주입 전압에 미치는 영향을 분석하고, 전류 신호 정보의 SNR을 개선하기 위하여 고주파 전류 맥동의 크기를 일정하게 제어하는 주입 전압을 인가하는 방법을 제안한다. 실험을 통하여, 제안된 방법의 성능을 검증하였다.

  • PDF

A Study on Speed Ripple Reduction of Compressor for Oil Cooler (오일 쿨러용 컴프레셔의 속도 맥동 저감에 관한 연구)

  • Shin, Gwang-Hyun;Lee, Jae-Seok;Hwang, Seon-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.113-114
    • /
    • 2016
  • 본 논문에서는 오일 쿨러용 컴프레셔의 속도 맥동에 의한 영향을 분석하고 이를 저감하기 위한 알고리즘을 제안한다. 일반적으로 공작기계의 공작물 가공부위에서 발생하는 열 변형 오차를 줄이기 위해 오일 쿨러용 컴프레셔가 사용된다. 하지만 싱글 로터리 구조의 컴프레셔에서 발생하는 기계적인 진동은 배관의 피로파괴와 소음을 야기하므로 반드시 저감시켜야 한다. 따라서 본 논문에서는 싱글 로터리 컴프레셔의 운전 시 발생하는 속도 맥동의 영향을 최소화할 수 있는 실시간 보상기법을 제안한다. 제안된 기법은 특정 맥동 성분을 저감할 수 있는 비례공진제어기를 적용하여 속도 맥동의 주파수 성분을 검출하여 이를 최소화 하는 방향으로 보상신호를 주입하는 방식이다. 시뮬레이션과 실험을 통해 제안하는 기법의 효용성을 검증한다.

  • PDF

Analysis on the Position Estimation Error in Position-Sensorless Operation of IPMSM Using Pulsating Square Wave Signal Injection (맥동하는 구형파 주입 매입형 영구 자석 전동기의 센서리스 운전에서 위치 추정 오차에 대한 분석)

  • Hwang, Chae-Eun;Lee, Younggi;Sul, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.221-222
    • /
    • 2017
  • 본 논문에서는 위치 센서에 의존하지 않는 매입형 영구자석 전동기의 센서리스 구동 시 전압 왜곡으로 인해 나타나는 위치 추정 오차를 이론적으로 분석하고자 한다. 특히, 추정 d축에 맥동하는 구형파 전압을 주입하는 방법에서 주입하는 신호의 주파수에 따라 위치 추정 성능이 달라지는 현상에 초점을 맞춘다. 무부하에서 스위칭 주파수의 신호를 주입할 때 전압 왜곡은 on/off sequence에서 서로 반대의 위상을 갖는 역상분 2고조파의 형태로 나타나며, 위치 추정 오차는 3고조파의 형태로 나타난다. 반면, 반스위칭 주파수의 신호를 주입하는 경우에는 샘플링 주기 동안 주입 전압 왜곡의 효과가 상쇄되기 때문에 인덕턴스의 영향만이 주로 고려되어 위치 추정 오차가 6고조파의 형태로 나타난다. 시뮬레이션과 실험을 통해 이론적 분석의 타당성을 검증하였다.

  • PDF

Development of 3 Channel Biomedical Signal Measurement System for Mac-yule (맥율용 3채널 생체신호 계측시스템 개발)

  • Byeon, M.K.;Kim, H.J.;Jang, J.K.;Han, S.W.;Huh, W.
    • Journal of IKEEE
    • /
    • v.11 no.1 s.20
    • /
    • pp.24-29
    • /
    • 2007
  • In this paper, we developed a Mac-Yule measurement system which consider psychological stable state of patience. The developed system consist with a hardware device that can derive a EEG, respiration and pulse wave, and a software which acquire a biological signal and signal processing The EEGs are derived with bipolar method from frontal head. The respiration signals obtain from nasal front with a transducer which consist with thermistor bridge. The pulse waves are detected from earlobe with photoplethysmograph method. A power spectrum of EEG are used as the decision parameters of psychological stable state of patience. The decision of Mac-Yule are defined as origin text method that of numbers of pulse to 1 respiration period. As the results of experiment with developed system, we could have a spectrum band discretion of EEG signal, stable respiration signal detection and automatic gain controlled pulse signal with realtime. And then, we could detect Mac-Yules from processed signals.

  • PDF

Detection of Radial Pulse by Combinational Fiber-optic Transducer (조합형 광섬유 트랜스듀서에 의한 요골맥파의 검출)

  • Park, Seung-Hwan;Hong, Seung-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.197-202
    • /
    • 1998
  • The human pulse wave is a vital biosignal that includes the diagnostic data related with the heart and the cardiovascular system of human body. Based on the mechanical transducing method, a pulse detection transducer using optical fiber was developed to acquire the pulses non-invasively. To improve the detection efficiency, we proposed a new design that consists of two combinational parts; detecting part, which is in contact with the pulsating skin and transmits the displacement motion of the pulsating skin to the sensing part, and sensing part, which converts the physical quantity transmitted from the detecting part to electronic signal. By using the new method, we confirmed that the proposed transducer can detect the C point(incisura) and the T wave(tidal wave) which is not easily detected by existing transducers.

  • PDF

A Study on Current Ripple Reduction Due to Offset Error and Dead-time Effect of Single-phase Grid-connected Inverters Based on PR Controller (비례공진 제어기를 이용한 단상 계통연계형 인버터의 데드타임 영향과 옵셋 오차로 인한 전류맥동 저감에 관한 연구)

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.157-158
    • /
    • 2014
  • 단상 계통연계형 인버터에서 전류센서를 통한 상전류 측정시 옵셋 오차는 전류센서와 측정 경로상에 위치한 아날로그 소자의 전압 불균형 및 비선형성으로 인하여 발생하게 된다. 또한 데드타임은 전력용 반도체 스위치를 제어하기 위한 PWM 신호 출력시 필연적으로 발생된다. 본 논문에서는 데드타임으로 인하여 왜곡된 상전류에 포함된 옵셋 오차에 의한 영향을 분석하고 동기좌표계 dq축 전류에 포함된 특정 고조파 성분을 제거하기 위하여 PR 제어기를 사용한 알고리즘이 제안되었다. 데드타임 및 옵셋 오차로 인해 발생된 전류맥동 보상을 위한 기준신호로는 동기좌표계 dq축 전류를 사용하였다. 제안된 알고리즘의 타당성을 시뮬레이션과 실험을 통하여 증명하였다.

  • PDF

A Study of Current Ripple Reduction Due to Offset Error in SRF-PLL for Single-Phase Grid-connected Converters (단상 계통연계형 컨버터의 SRF-PLL 옵셋 오차로 인한 전류 맥동 저감에 관한 연구)

  • Seong, Eui-Seok;Jeong, Byeong-Guk;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.451-452
    • /
    • 2014
  • 본 논문에서는 단상 계통연계형 컨버터의 전원 위상각을 추종함에 있어 필수적인 전압 센서의 옵셋 오차에 대한 영향을 분석하고 이를 검출 및 보상하기 위한 알고리즘을 제안하였다. 전원전압 측정에 따른 옵셋 오차는 전원 주파수의 1배 맥동을 야기하여 전원 위상각이 왜곡된다. 왜곡된 전원 위상각에 의한 좌표변환시 동기 좌표계 dq축 전류에 전원 주파수 1배의 맥동을 야기하며 이는 계통측 상전류에 직류성분과 전원 주파수 2배의 고조파 성분을 발생시키게 된다. 따라서, 본 논문에서는 전원측정시 야기되는 옵셋 오차의 영향을 분석하고 이의 검출신호로 전원 위상각 제어기의 적분출력을 선정하였다. 또한 RMS(Root Mean Square) 기법을 이용하여 옵셋 성분을 검출 및 보상하는 알고리즘을 제안하였다. 제안된 알고리즘의 성능은 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument (산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.452-456
    • /
    • 2000
  • A measurement unit and signal processing algorithm have been developed for predicting arterial oxygen saturation noninvasively. The measurement set-up was composed of a probe including light source and photodetector, optical signal processing section, LED driving circuit, PC interface software for data acquisition and data processing software. Light from the LED's was irradiated onto the finger nail bed and transmitted light was measured at different wavelengths. An effective baseline correction method was developed and measured data were analyzed by using various data processing methods and prediction algOlithms. For performance evaluation, a pulse oximeter simulator (Bio- Tek Instrument Inc.) was used as reference. The best performance in terms of the correlation coefficient and the standard deviation was obtained under the following conditions; when the arterial signals were computed in terms of area rather than peak-valley difference, and when the algorithm calculating by $In(I_p/I_v)/I_{avr}$ value for pulsation waveform was used. In in vivo test, prediction was improved when the developed baseline correction method was used. In addition, wavelengths of 660 nm and 940 nm provided better linearity and precision than wavelengths of 660 nm and 805 nm. 05 nm.

  • PDF