• Title/Summary/Keyword: 만성폐색성폐질환

Search Result 5, Processing Time 0.023 seconds

Chronic Obstructive Pulmonary Disease in a Dressage Horse (마장마술마에서 발생한 만성폐쇄성폐질환 증례)

  • Jeong, Hyo-Hoon;Ahn, Kei-Myung;Kim, A-Ram;Roh, Ha-Jung;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.27 no.2
    • /
    • pp.194-197
    • /
    • 2010
  • A 14-year-old gelded dressage horse weighing 500 kg was presented to the Equine Medical Center of the Seoul Racecourse of Korea Racing Authority (KRA) due to coughing and mucopurulent nasal discharge. The horse was initiated with empirical antibiotic in the first place. However, the clinical signs did not improve but were rather exacerbated even after 3 weeks of therapy. Extensive diagnostic procedures including transtracheal wash (TTW) fluid cytology were undertaken. The localized wheezes and crackles were auscultated and an increase in the amount of mucopurulent exudate in trachea was observed at endoscopy. Infiltration of neutrophils was observed in the TTW fluid cytology implying chronic obstructive pulmonary disease (COPD). Therefore, the systemic glucocorticoid therapy was to be given for 3 weeks with improved ventilation provided at the same time. The respiratory symptoms started to improve in 7 days of therapy and were fully resolved by when the therapy was terminated. The horse is clinically normal now and being monitored for development of any signs of chronic obstructive pulmonary disease.

An Evaluation of the Accuracy of Mini-Wright Peak Flowmeters in Patients with Asthma and Chronic Obstructive Pulmonary Disease (천식 및 만성폐쇄성폐질환 환자에서 Mini-Wright Peak Flowmeter로 측정한 최대호기유속의 정확도)

  • Choi, Won-Il;Han, Seung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.3
    • /
    • pp.310-319
    • /
    • 2001
  • Background : The peak flowmeter is very useful in monitoring of out-patients as well as those in emergency departments because of its convenience and simplicity with low cost. There have been many studies aimed at determining the accuracy and reproducibility of the peak flow meter in normal population. However, there is a paucity of reports regarding its accuracy in patients with chronic obstructive pulmonary disease(COPD) or asthma. The accuracy of the peak expiratory flow(PEF) measured with a mini-Wright peak flowmeter was assessed by a comparison with the results of a mass flow sensor. Methods : The PEF measurements were performed in 108 patients aged 19-82 years presenting with either a chronic obstructive lung disease or asthma before and after inhaling salbutamol. The PEF measurements from the mini-Wright flowmeter were compared with those obtained by the calibrated mass flow sensor. Results : The average of the readings taken by the mini-Wright meter were 37-39 l/min higher than those taken by the mass flow sensor. The average percentage error of the mini-Wright meter were higher, ranging less than 300 l/min. The mean of the differences between the values obtained using both instruments (the bias)$\pm$limits of agreement(${\pm}2$ SD) were $37.1{\pm}90\;l/min$ for the PEF(p<0.001). Conclusions : The mini-Wright peak flowmeter overestimated the flows in patients with COPD or asthma. It was also found that the accuracy of the mini-Wright peak flowmeter decreased in its mid to low range. The limits of agreement are wide and the difference between the two instruments is significant. Therefore, the measurements made between the two types of machines in patients with asthma or COPD cannot be used interchangeably.

  • PDF

Clinical Observation of the Pulmonary Aspergilloma (폐국균종(Plulmonary Aspergilloma)의 임상적 고찰)

  • Kim, Hyeung-Il;Kim, Sung-Sook;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.157-165
    • /
    • 1993
  • The authors conducted a clinical observation of 13 cases of pulmonary aspergilloma at Yeungnam University Hospital from March 1983 to March 1992, and the following results were observed : 1) The male to female ratio was 1 : 1.2, and the age distribution was ranged 30 to 67 years old. 2) All cases were symptomatic : hemoptysis, cough, sputum and dyspnea. Especially, hemoptysis was the presenting compliant in 10 patients(77%). 3) The underlying lung disease were pulmonary tuberculosis in 9, COPD in 5 and bronchiectasis in 2, 3 cases were without underlying disease. 4) According to radiographic appearance, 8 cases had the typical crescent sign and 5 cases were seen nodular lesion. And the lesions of 11 cases were located in both upper lung. 5) 10 cases were treated with surgical resection. Among these cases, 8 cases were alieved and 2 cases, died. And other 3 cases were treated with conservative treatment. We suggest that these findings would be helpful for the diagnosis and treatment of pulmonary aspergilloma and further study might be needed to evaluate the prognosis of pulmonary aspergilloma.

  • PDF

Life-Sustaining Procedures, Palliative Care, and Cost Trends in Dying COPD Patients in U.S. Hospitals: 2005~2014

  • Kim, Sun Jung;Shen, Jay;Ko, Eunjeong;Kim, Pearl;Lee, Yong-Jae;Lee, Jae Hoon;Liu, Xibei;Ukken, Johnson;Kioka, Mutsumi;Yoo, Ji Won
    • Journal of Hospice and Palliative Care
    • /
    • v.21 no.1
    • /
    • pp.23-32
    • /
    • 2018
  • Purpose: Little is known regarding the extent to which dying patients with chronic obstructive pulmonary disease (COPD) receive life-sustaining procedures and palliative care in U.S. hospitals. We examine hospital cost trends and the impact of palliative care utilization on the use of life-sustaining procedures in this population. Methods: Retrospective nationwide cohort analysis was performed using National Inpatient Sample (NIS) data from 2005 and 2014. We examined the receipt of both palliative care and intensive medical procedures, defined as systemic procedures, pulmonary procedures, or surgeries using the International Classification of Diseases, 9th revision (ICD-9-CM). Results: We used compound annual growth rates (CAGR) to determine temporal trends and multilevel multivariate regressions to identify factors associated with hospital cost. Among 77,394,755 hospitalizations, 79,314 patients were examined. The CAGR of hospital cost was 5.83% (P<0.001). The CAGRs of systemic procedures and palliative care were 5.98% and 19.89% respectively (each P<0.001). Systemic procedures, pulmonary procedures, and surgeries were associated with increased hospital cost by 59.04%, 72.00%, 55.26%, respectively (each P<0.001). Palliative care was associated with decreased hospital cost by 28.71% (P<0.001). Conclusion: The volume of systemic procedures is the biggest driver of cost increase although there is a cost-saving effect from greater palliative care utilization.

Validity of Peak Expiratory Flow for Assessing Reversible Airflow Obstruction (기류 가역성 평가에 있어서 최대호기유속 측정의 유용성)

  • Chol, Won-Il;Kwak, Jin-Ho;Kwon, Doo-Young;Han, Seung-Beom;Jeon, Young-June
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.522-529
    • /
    • 2000
  • Backgrounds : Assessment of the presence and degree of reversibility of airflow obstruction is clinically important in patients with asthma or chronic obstructive pulmonary disease. The measurement of peak expiratory flow(PEF) is a simple, fast, and cheap method to assess the severity of obstruction and its degree of reversibility. Assessing the reversibility of airflow obstruction by peak expiratory flow(PEF) measurements is practicable in general practice, but its usefulness has not been well investigated. We compared PEF and $FEV_1$ in assessing reversibility of airflow obstruction in patients with chronic obstructive pulmonary disease or asthma and developed a practical criterion for assessing the presence of reversibility in general practice. Methods : PEF measurements were performed (Spirometry) in 80 patients(aged 24-78) with a history of asthma or chronic obstructive lung disease before and after the inhalation of 200 g salbutamol. The change in PEF was compared with the change in forced expiratory volume in one second($FEV_1$). Reversible airflow obstruction was analyzed according to American Thoracic Society(ATS) criteria. Results : A 12% increase above the prebronchodilator value and a 200ml increase in either FVC or $FEV_1$ reversibility were observed in 45%(36) of the patients. Relative operating characteristic(ROC) analysis showed that an absolute improvement in PEF of 30 l/min gave optimal discrimination between patients with reversible and irreversible airflow obstruction(the sensitivity and specificity of an increase of 30 l/min in detecting a 12% increase above the prebronchodilator value and a 200ml increase in either FVC or $FEV_1$ were 72.2% and 72.7% respectively, with a positive predictive value of 68.4%). Conclusions : Absolute changes in PEF can be used to diagnose reversible airflow obstruction.

  • PDF