• Title/Summary/Keyword: 막오염 저감

Search Result 66, Processing Time 0.029 seconds

Micro-Filtration Performance of Metal Membrane md Fouling Reduction by Intermittent Ozonation (금속 막의 정밀 여과 특성 및 간헐적 오존 처리에 의한 막 오염 저감)

  • 김종오;정종태
    • Membrane Journal
    • /
    • v.14 no.1
    • /
    • pp.66-74
    • /
    • 2004
  • Total resistance of membrane in a micro-filtration system using a metal membrane was mainly attributed to the permeate resistance of cake layer($R_c$), which was formed by deposited particles from the physico-chemical interactions of solids on membrane surface. Intermittent back ozonation was highly effective than the air backwashing for fouling reduction. As far the operational effect, under same ozone injection, the increase of gas flow-rate was more favorable than the increase of injection time far the recovery of permeation flux. As the filtration time was longer, the effect of flux recovery by intermittent back-ozonation decreased. Therefore, it is preferable to operate membrane cleaning before the foulant is consolidated on membrane surface.

Investigation of Organic Fouling with AFM(Atomic Force Microscope) in Reverse Osmosis Membrane and Forward Osmosis Membrane (FO와 RO막에서 AFM(Atomic Force Microscope)을 이용한 유기 막 오염 연구)

  • Kuk, Ji-Hoon;Lee, Sang-Youp;Hong, Seung-Kwan
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.102.1-102.1
    • /
    • 2010
  • 대체수자원 중 막여과 기술에 대한 관심이 지속적으로 높아지고 있다. 하지만, 이러한 막여과 기술에는 fouling이 발생시 효율저감, flux저감, 소모에너지 증대 등 문제점이 발생한다. 이러한 fouling저감을 위해 막 표면특성분석을 통한 기초연구가 필요하다고 보고 이 연구를 진행하였다. AFM을 이용하여 CML입자와 막의 상호작용을 통해 초기 막오염 경향을 예측할 수 있다.

  • PDF

Membrane fouling reduction using electro-coagulation aided membrane bio-reactor (전기응집 분리 막 생물반응기의 막 오염 저감)

  • Kim, Wan-Kyu;Hong, Sung-Jun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.105-114
    • /
    • 2018
  • Membrane fouling in EC-MBR (Electro-Coagulation aided Membrane Bio-Reactor) processes was evaluated according to the operating parameters, such as current density and contact time. In addition, the fouling mechanism was investigated. Compared to the control (i.e., no electro-coagulation), membrane fouling for filtration of the activated sludge suspension after electro-coagulation was reduced significantly. Membrane fouling was improved further when the contact time was doubled under a low current density of $2.5A/m^2$. On the other hand, membrane fouling was not mitigated further, as expected, even though the contact time was doubled from 12 to 24 hr. at a current density of $10A/m^2$. This indicates that the overall decrease in membrane fouling is a function of the product of the current density and contact time. The particle size of the activated sludge flocs after electro-coagulation was changed slightly, which means that the membrane fouling reduction was not attributed to a larger particle size resulting from electro-coagulation. The experimental confirmed that the dynamic membrane made from aluminum hydroxide, Al(OH)3, and/or aluminum phosphate, Al(PO4), which had been formed during the electro-coagulation, played a key role on the reduction of membrane fouling. The dynamic membrane prevents the particles in the feed solution from deposition to the membrane pores and cake layers. Dynamic membrane formation as a result of electro-coagulation plays a critical role in the mitigation of membrane fouling in EC-MBR.

Fouling of Ion Exchange Membranes and Their Fouling Mitigation (이온교환막의 막오염 및 오염저감)

  • 문승현;이홍주
    • Membrane Journal
    • /
    • v.12 no.2
    • /
    • pp.55-66
    • /
    • 2002
  • fouling phenomena of ion exchange membranes were reviewed for improved design and operation of electodialysis. The membrane fouling index for electrodialysis (EDMFI) was defined for the quantitative analysis of fouling potential as an analogy to the pressure-driven membrane process. fouling phenomena were compared in the electrodialysis experiments with inorganic foulant (silica sol) and organic foulants (humate and bovine serum albumin (BSA)), and their fouling potentials were analyzed using the fouling index. The comparison showed that the EDMFI could be used as a quantitative measure of the fouling tendency in electrodialysis processes. As a novel fouling mitigation method, square wave power was reported to be effective in electrodialysis with organic foulants. The square wave powers having the pulsed electric field enabled to reduce the membrane fouling significantly at an optimal frequency.

Membrane bioreactor immersed in the aerated settler to reduce membrane fouling (고도처리용 MBR의 막오염 저감을 위한 막분리 침전조에 대한 연구)

  • Shin, Dong-Whan;Park, Hun-Hwee;Chang, In-Soung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.585-586
    • /
    • 2006
  • 본 연구에서는 고도처리를 위한 BNR 공정에 사용되는 MBR (Membrane Bioreactor)의 막 오염(membrane fouling)을 저감시키기 위해 분리막을 침지시킨 침전조를 상하로 나누어 상부는 폭기조로, 하부는 침전조의 역할을 수행하게 하는 새로운 형태의 막분리 침전조 (aerated settler)의 성능을 평가 하였다. 막분리 침전조는 상하로 구분하기 위해서 baffle을 설치하였다. 파일럿 규모 ($Q=50m^3/d$)의 MBR 공정은 실제 오수를 유입수로 사용하였으며 약 6개월간 운전하였다. 탈질을 위하여 막분리 침전조 하부에서 무산소조로 반송되는 반송수의 DO를 크게 줄어들게 함으로써 무산조에서의 탈질효율이 증가되었다. 처리수의 총 TN 제거율은 75%이었다. 또한 막분리침전조 상 하부의 MLSS 농도 차에 의해 상부에 침지된 막 모듈은 기존의 MBR 공정보다 막 오염 저감 효과가 있어서 세정주기가 증가하였다. 운전 개시 후 4개월째 되는 시점에 TMP가 40cmHg에 도달하여 1회 화학적 약품세정만이 필요하였다.

  • PDF

Measurement of critical time for optimum backpulsing time (최적 역충격을 위한 임계시간 측정)

  • 박상현;장진호;노수홍
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.169-171
    • /
    • 1998
  • 막오염을 저감하는 여러 방법중의 하나인 backpulsing은 짧은 시간동안 고빈도로 역세척을 하는 것이다. 본 연구는 주기적인 역충격(frequence backpulsing)에 의한 중공사막의 오염을 줄이는데 있어서 적절한 역세 주기를 구하기 위하여 막이 오염되기 이전의 순수투과능을 나타내는 시간인 임계시간(critical time)을 구하는 것이 목적이다.

  • PDF

Characterization of the Nano-material U Membranes with Excellent Fouling Resistance (막 오염 저항성이 우수한 나노 소재 정밀 여과막의 특성 연구)

  • Choi Jeong Hwan;Lee Jeong Bin;Kim In-chul
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.289-296
    • /
    • 2005
  • In the MBR process, the membrane fouling occurs seriously on the membrane surface. In general, the membrane fouling is attributed to factors such as deposition or adhesion of sludge floc. The occurrence of fouling is a main cause of a decrease in membrane module fluk. At this study, our MBR membrane is manufactured by nano-particle with excellent anti-fouling character. The fine nano-material which can repel the sludge Hoc from the membrane surface is distributed in the membrane surface. We confirm anti-fouling effect, test continuously in the pilot site.

Fauling Reducton of Hollow Fiber Membrane with backpulsing (Backpulsing을 이용한 중공사막의 오염 저감)

  • 김영락;최찬섭;박상현;장진호;노수홍
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.76-78
    • /
    • 1998
  • 1. 서론 : 수처리공정에서의 막오염은 효과적인 공정운용을 위해 주요 문제로 인식되고 있으며 막오염은 막표면이나 세공에서 물질의 흡착, 부착 그리고 축적 등과 같은 일련의 메카니즘에 의해 투과율을 저하시키는 결과를 초래한다. 본 연구는 주기적인 역세척(frequency backpulsing)에 의한 중공사막에서의 오염 현상을 규명하여 정수 처리 공정에서 막오염을 최소화시키는 운전 조건을 확립하는 것을 목적으로 하고 있다.

  • PDF