• Title/Summary/Keyword: 루프실

Search Result 30, Processing Time 0.023 seconds

Comparison of Solid Circulation Characteristics with Change of Lower Loop Seal Geometry in a Circulating Fluidized Bed (순환유동층에서 하부 루프실 형태 변화에 따른 고체순환 특성 비교)

  • Lee, Dong-Ho;Jo, Sung-Ho;Jin, Gyoung-Tae;Yi, Chang-Keun;Ryu, Ho-Jung;Park, Seung Bin
    • Korean Chemical Engineering Research
    • /
    • v.52 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Circulating fluidized bed system consists of SEWGS reactor - lower loop seal - regeneration reactor - riser - cyclone - upper loop seal has been used for solid circulation between the SEWGS reactor and the regeneration reactor in a SEWGS system for pre-combustion $CO_2$ capture. A vertical type lower loop seal has been used in current system but this lower loop seal requires high gas flow rate through the lower loop seal for fluidization and smooth solid circulation, and consequently, causes slugging behavior sometimes. To overcome these disadvantages, inclined type lower loop seal was proposed by this study. Solid circulation characteristics with change of lower loop seal geometry were measured and compared in a bubbling - bubbling - riser type circulating fluidized bed using $CO_2$ absorbent (P-78) as bed material at ambient temperature and pressure. We could conclude that the inclined lower loop seal is better than the vertical type lower loop seal from the viewpoints of minimum flow rate requirement for stable solid circulation and solid height change during solid circulation.

Analysis of Accuracy of Fault Location using Murray Loop (유도 및 고장저항에 따른 머레이루프를 이용한 고장점 탐지 정확도 분석)

  • Park, Jin-Woo;Yang, Byeong-Mo;Mun, Kyeong-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.533-534
    • /
    • 2011
  • 머레이루프 시험의 경우 기본적인 시험회로 구성을 위해 고장상과 인접한 건전상이 존재하여야 하는 단점이 있지만 써지 진행파를 이용하지 않기 때문에 크로스본딩 시스템과 무관하게 개략 고장점탐지를 할 수 있는 방법이란 측면에서 크로스본딩 시스템의 지중케이블 고장점 탐지방법으로 추천가능한 방법이라 할 수 있다. 본 논문에서는 머레이루프 시험시 인접선로에 의한 유도전류의 영향, 시스템 시스접지에 의한 영향, 고장점 고장저항 등에 따른 머레이루프 실증시험을 시행하여 각각의 고장상황에 대한 고장점 탐지 정확도를 살펴보고 실 고장점 탐지 시험시 머레이루프 시험 방안을 제시하고자 한다.

  • PDF

Design of a Multirate Discrete-time Sliding Mode Controller (멀티레이트 이산시간 슬라이딩 모드 제어기 설계)

  • Choi, Jae-Mo;Chae, Su-Kyoung;Jeong, Dong-Seul;Chung, Chung-Choo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2179-2181
    • /
    • 2003
  • 기존의 이산시간 슬라이딩 모드 제어기에서는 주어진 슬라이딩 평면으로부터 등가 제어기를 설계하고 그로부터 폐루프 시스템의 고유값이 결정 되어 폐루프 시스템의 극점을 임의로 배치시키는 것이 어려웠다. 최근 슬라이딩 모드제어에 극점 배치기법을 도입하여 폐루프 시스템의 고유값을 임의로 배치시킬 수 있는 방법이 소개되었다. 그러나 극점 배치 기법은 루프 전달함수의 이득과 위상에 대한 여유도 관점에서 설계된 제어기가 아니므로 직접적으로 이득과 위상에 대한 여유도를 보장하기가 힘들다. 따라서 본 논문에서는 루프 전달함수의 이득과 위상에 대한 여유도를 확보할 수 있고 측정 잡음에 대한 민감성을 줄이기 위해 LTR과 멀티레이트 출력 제어기법을 적용해 해결하는 방법을 제안한다.

  • PDF

An Investigation on the Environmental Effect of the Magnetic Field due to Overhead Transmission Line (가공송전선로에 의한 자계환경영향 검토)

  • Jeong, Seung-Yong;Lim, Yun-Sok;Koo, Ja-Yoon;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.144-146
    • /
    • 2004
  • 송전선로 주변의 전자계 노출은 소아들의 암 발생/사망과 성인의 암 등 여러 가지 질병 발생 가능성이 항상 있으므로 전자계 노출을 장기간 계속적으로 받고 있는 환경을 관찰하는 것이 가장 중요하다. 따라서 본 연구에서는 이에 대한 연구기반을 형성하기 위해 송전 선로의 모델과 현장 실측을 통해 송전선로 자계치를 계산하여 시뮬레이션 하고자한다. 시뮬레이션을 통해 산출된 자계치를 이용하여 최근 효과적인 자계 저감책으로 보고되고 있는 수동루프에 의한 자계저감효과를 검토하고자 한다. 입력된 데이터는 765kV 실 송전선로를 모델로 사용하였으며, 자계의 계산 및 수동 루프에 의한 자계 저감 효과를 알아보기 위해서 미국 EPRI에서 개발한 자계 계산 전용 프로그램인 EMF Modeler를 이용하였다. 먼저 송전선로에 의해 발생되는 자계의 원리를 서술하였으며, 수동 루프를 통한 자계 감소 정도를 수식으로 유도하였고, EMF Modeler를 통하여 송전선 주변의 자계 분포 및 수통루프에 의한 자계 저감 효과를 각각 확인하였다.

  • PDF

An Investigation on the Environmental Effect of the Magnetic Field due to Overhead Transmission Line (가공송전선로에 의한 자계환경영향 검토 및 수동루프에 의한 자계저감효과 검토)

  • Jeong, Seung-Yong;Lim, Yun-Sok;Lee, Sang-Wha;Koo, Ja-Yoon;Lee, Dong-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.116-118
    • /
    • 2004
  • 송전선로 주변의 전자계 노출은 소아들의 암 발생/사망과 성인의 암 등 여러 가지 질병 발생 가능성이 항상 있으므로 전자계 노출을 장기간 계속적으로 받고 있는 환경을 관찰하는 것이 가장 중요하다. 따라서 본 연구에서는 이에 대한 연구기반을 형성하기 위해 송전 선로의 모델과 현장 실측을 통해 송전선로 자계치를 계산하여 시뮬레이션 하고자한다. 시뮬레이션을 통해 산출된 자계치를 이용하여 최근 효과적인 자계 저감책으로 보고되고 있는 수동루프에 의한 자계저감효과를 검토하고자 한다. 입력된 데이터는 765kV 실 송전선로를 모델로 사용하였으며, 자계의 계산 및 수동 루프에 의한 자계 저감 효과를 알아보기 위해서 미국 EPRI에서 개발한 자계 계산 전용 프로그램인 EMF Modeler를 이용하였다. 먼저 송전선로에 의해 발생되는 자계의 원리를 서술하였으며, 수동 루프를 통한 자계 감소 정도를 수식으로 유도하였고, EMF Modeler를 통하여 송전선 주변의 자계 분포 및 수동루프에 의한 자계 저감 효과를 각각 확인하였다.

  • PDF

Effect of Loop Seal Geometry on Solid Circulation in a Gas-Solid Fluidized Bed (기체-고체 유동층에서 루프실의 형상이 고체순환에 미치는 영향)

  • RYU, HO-JUNG;JO, SUNG-HO;LEE, SEUNG-YONG;LEE, DOYEON;NAM, HYUNGSEOK;HWANG, BYUNG WOOK;KIM, HANA;WON, YOO SEOB;KIM, JUNGHWAN;BAEK, JEOM-IN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.312-319
    • /
    • 2019
  • Effect of loop seal geometry on solid circulation characteristics was investigated with two different types of upper loop seals and lower loop seals in a gas-solid fluidized bed system. Upper loop seal which has a wide gap between solid intake and outlet parts requires more fluidization gas to maintain smooth solid circulation. Moreover, the lower loop seal which has a wide gap requires more fluidization gas to achieve the same solid circulation rate. These results can be explained by results of minimum fluidization velocity in the lower loop seals. Consequently, if a loop seal has a wide gap between solid intake and outlet parts, more fluidization gases should be fed to ensure enough solid circulation rate and smooth solid circulation.

A Study on the Loop Detector System for Real-Time Traffic Adaptive Signal Control (실시간 교통신호제어를 위한 루프 검지기 체계 연구)

  • 이승환;이철기
    • Journal of Korean Society of Transportation
    • /
    • v.14 no.2
    • /
    • pp.59-88
    • /
    • 1996
  • This study has determined optimal type, and location of loop detector to measure accurately traffic condition influenced by traffic variation with real time. Optimal type of loop detector for through vehicle at stop bar was determined by confidences of occupancy period, and nonoccupancy period, and so appropriate detector type for application to real time traffic control system has been decided on special loop detector.

    shows types and winding methods of existing detector (num1) and special detector (num 7,8) determined. It is desired that optimal location of through loop detector should be installed within 50cm of stop bar owing to vehicle behavior. And optimal location of loop detector for left turn vehicle is determined by left turn vehicle behavior on stop bar. In the case of install only one loop, it is desirable that within 20cm of stop bar. Both the special loop (1.8 × 4.0m : num 1.7) and existing loop (1.8 × 1.8m : num1) would be suitable. A location standard aspects, while regarding as economic, existing loop (1.8 × 1.8m : num1) would be suitable. A location of the queue detector and the spillback prevention detector considering the link length, the pedestran crossing is be or not and the estimation range of queue. And if the link length is shorter than 250m, locations of queue detector and spillback protect detector must be considered in the respect of queue management.

  • PDF

Improvement of Magnetic SE Measurement of Shielded Rooms Using Rectangular Loop Antennas (직사각형 루프 안테나를 이용한 차폐실의 자기장 차폐효과 측정 방법 개선)

  • Park, Hyun Ho;Hyoung, Chang Hee;Kwon, Jong Hwa
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.320-323
    • /
    • 2019
  • This paper examines a disadvantage of low-frequency magnetic shielding measurement based on MIL-STD-188-125-1. A rectangular loop antenna is proposed as an improvement over conventional circular loop antennas for measuring magnetic shielding. Simulation and experiment are used to demonstrate that the proposed rectangular loop outperforms the circular loop for a more reliable shielding measurement at low frequency range.

Multi-Optimization Study of a Boiler System Using Immune Algorithms (면역 알고리즘을 이용한 보일러 시스템의 다목적 성능 최적화 연구)

  • 김동화;박진일
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.05a
    • /
    • pp.177-181
    • /
    • 2003
  • PID(Proportional-Integral-Derivative)제어기는 제어악고리즘의 단순성과 실 현장에서의 강인성 등으로 산업용 보일러의 제어시스템서 주로 이용되어 왔다. 그러나 다중 루프를 가진 보일러 시스템에서는 루프간의 상호 간섭 영향 등으로 부하 변화에 따라 요구되는 증기(steam)압력, 증기 유량(steam flow)변화 등을 동시에 만족하도록 급수 유량, 연교 유량, 공기 유량 등을 PlH제어기만으로 제어하는 것은 어렵다. 본 연구에서는 보일러 시스템의 다목적 성능 최적화에 각각의 적합도 함수 $f_{a}$ , $f_{b}$, $f_{c}$를 정의하고 면역 알고리즘을 이용해 최적화를 구하고 그 결과에 대한 특성과 유효성을 검토하였다.다.다.

  • PDF

Application of a Conventional Advanced Control for a Glass Furnace (유리 용해로를 위한 고전 고급제어의 적용)

  • Moon, Un-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2590-2592
    • /
    • 2000
  • 본 논문에서는 TV 브라운관 유리용해로의 온도 제어를 위한 고전 고급 제어 (Conventional Advanced Control) 알고리듬을 제시한다. 용해로의 특성에 맞도록 중요한 입출력 변수를 선정한 후, 공정 실험을 통하여 얻어진 데이터를 바탕으로 입출력 변수들간의 초보적인 FOPDT (First Order Plus Dead Time) 모델들의 조합으로 용해로를 모델링하였다. 수립된 모델을 바탕으로 주요 입출력을 PI (Proportional - Integral) 형태의 cascade 및 단일 궤환 루프(Single feedback loop)들의 조합으로 제어기를 구성하였다. 제시된 알고리듬은 기존 용해로에 설치되어 있는 DCS를 이용하여 구현되었고, 일 150톤 생산 규모의 용해로에 성공적으로 실적용되었다.

  • PDF