• Title/Summary/Keyword: 레이저 유도 플라즈마 분광법

Search Result 26, Processing Time 0.029 seconds

Laser-induced plasma emission spectra of halogens in the helium gas flow and pulsed jet (헬륨 가스 플로우와 가스 펄스 젯에서 할로겐족 원소들의 레이저유도 플라즈마 방출 스펙트럼)

  • Lee, Yonghoon;Choi, Daewoong;Gong, Yongdeuk;Nam, Sang-Ho;Nah, Changwoon
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.235-244
    • /
    • 2013
  • Detection of halogens using laser-induced breakdown spectroscopy (LIBS) in open air is very difficult since their strong atomic emission lines are located in VUV region. In NIR region, there are other emission lines of halogens through electronic transitions between excited states. However, these lines undergo Stark broadening severely. We report the observation of the emission lines of halogens in laser-induced plasma (LIP) spectra in NIR region using a helium gas flow. Particularly, the emission lines of iodine at 804.374 and 905.833 nm from LIPs have been observed for the first time. In the helium ambient gas, Stark broadening of the emission lines and background continuum emission could be suppressed significantly. Variations of the line intensity, plasma temperature, and electron density with the helium flow rate was investigated. Detection of chlorine and bromine in flame retardant of rubbers was demonstrated using this method. Finally, we suggest a pulsed helium gas jet as a practical and ecomonical helium gas source for the LIBS analysis of halogens in open air.

플라즈마 공정 진단을 위한 공간 분해 발광 분광 분석법 소개

  • Park, Chang-Hui;Kim, Dong-Hui;Choe, Seong-Won;Lee, Chang-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.81-81
    • /
    • 2013
  • 반도체, LCD, MEMs 등 미세 전자소자의 제작과 깊은 관련이 있는 IT 산업은 자동차 산업과 함께 세계 경제를 이끌고 있는 핵심 산업이며, 그 발전 가능성이 크다고 할 수 있다. 이 중 반도체, LCD 공정 기술에 관해서 대한민국은 세계를 선도하여 시장을 이끌어 나가고 있는 실정이다. 이들의 공정기술은 주로 높은 수율(yield)을 기반으로 한 대량 생산 기술에 초점이 맞추어져 있기 때문에, 현재와 같은 첨예한 가격 경쟁력이 요구되는 시대에서 공정 기술 개발을 통해 수율을 최대한으로 이끌어 내는 것이 현재 반도체를 비롯한 미세소자 산업이 직면하고 있는 하나의 중대한 과제라 할 수 있다. 특히 반도체공정에 있어 발전을 거듭하여 현재 20 nm 수준의 선폭을 갖는 소자들의 양산이 계획 있는데 이와 같은 나노미터급 선폭을 갖는 소자 양산과 관련된 CD (critical dimension)의 감소는 공차의 감소를 유발시키고 있으며, 패널의 양산에 있어서 생산 효율 증가를 위한 기판 크기의 대형화가 이루어지고 있다. 또한, 소자의 집적도를 높이기 위하여 높은 종횡비(aspect ratio)를 요구하는 공정이 일반화됨에 따라 단일 웨이퍼 내에서의 공정의 균일도(With in wafer uniformity, WIWU) 및 공정이 진행되는 시간에 따른 균일도(Wafer to wafer uniformity)의 변화 양상에 대한 파악을 통한 공정 진단에 대한 요구가 급증하고 있는 현실이다. 반도체 및 LCD 공정에 있어서 공정 균일도의 감시 및 향상을 위하여 박막, 증착, 식각의 주요 공정에 널리 사용되고 있는 플라즈마의 균일도(uniformity)를 파악하고 실시간으로 감시하는 것이 반드시 필요하며, 플라즈마의 균일도를 파악한다는 것은 플라즈마의 기판 상의 공간적 분포(radial direction)를 확인하여 보는 것을 의미한다. 현재까지 플라즈마의 공간적 분포를 진단하는 대표적인 방법으로는 랭뮤어 탐침(Langmuir Probe), 레이저 유도 형광법(Laser Induced Fluorescence, LIF) 그리고 광섬유를 이용한 발광분광법(Optical Emission Spectroscopy, OES)등이 있으나 랭뮤어 탐침은 플라즈마 본연의 상태에서 섭동(pertubation) 현상에 의한 교란, 이온에너지 측정의 한계로 인하여 공정의 실시간 감시에 적합하지 않으며, 레이저 유도 형광법은 측정 물질의 제한성 때문에 플라즈마 내부에 존재하는 다양한 종의 거동을 살필 수 없다는 단점 및 장치의 설치와 정렬(alignment)이 상대적으로 어려워 산업 현장에서 사용하기에 한계가 있다. 본 연구에서는 최소 50 cm에서 최대 400 cm까지 플라즈마 내 측정 거리에서 최대 20 mm 공간 분해가 가능한 광 수광 시스템 및 플라즈마 공정에서의 라디칼의 상태 변화를 분광학적 비접촉 방법으로 계측할 수 있는 발광 분광 분석기를 접목하여 플라즈마 챔버 내의 라디칼 공간 분포를 계측할 수 있는 진단 센서를 고안하고 이를 실 공정에 적용하여 보았다. 플라즈마 증착 및 식각 공정에서 형성된 박막의 두께 및 식각률과 공간 분해발광 분석법을 통하여 계측된 결과와의 매우 높은 상관관계를 확인하였다.

  • PDF

Measurement of combustion gas temperature using laser-induced breakdown spectroscopy (레이저 유도 플라즈마 분광분석법을 이용한 연소 가스 온도 측정 기술)

  • Lee, Seok Hwan;Kim, Yong-Gyoo;Kang, Woong;Joung, Wukchul;Lee, Joo Hyun;Kim, Sunghun;Yang, Inyoung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.285-289
    • /
    • 2017
  • Laser-induced breakdown spesctroscopy (LIBS) is a technique that complements the disadvantages of conventional laser-based combustion diagnosis techniques such as weak signal strength, complex equipment configuration, and low accuracy. In this study, basic research was carried out to measure the combustion gas temperature of scramjet engines using LIBS. Spray flames were generated from Jet A-1 fuel used in scramjet engines and gas temperatures were measured at the top of the flames with a calibrated thermocouple. The LIBS signals were acquired at the same points as the temperature measurement positions of the thermocouple. The LIBS spectra were analyzed to obtained a calibration curve between the LIBS signal and the reference temperature measured at the thermocouple. Therefore, it was confirmed that the combustion gas temperature can be measured in-situ using LIBS.

  • PDF

A Study on the Corrosion Characteristics of a Metal Surface by Laser-Induced Breakdown Spectroscopy (레이저 유도 플라즈마 분광분석법을 적용한 금속표면의 부식 특성에 관한 연구)

  • Kang, Dongchan;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.83-89
    • /
    • 2017
  • The corrosion of metal specimens was analyzed in this study using laser-induced breakdown spectroscopy. The samples used in the study were magnesium alloys and corrosion, and standard specimens were prepared and analyzed using surface and depth analysis. The spectral wavelengths used in the oxide layer analysis were 777.196 nm, 777.421 nm, and 777.543 nm. The spectral line of the surface corrosion was confirmed by experimentation, and surface micro morphology analysis was performed using an optical microscope. Approximately $100{\mu}m$ corrosion depth was confirmed via laser irradiation in the depth direction. The results of laser-induced breakdown spectroscopy and the SEM-EDS analysis were compared and analyzed.

Development of LIBS Plug for Combustor Diagnosis (연소실 진단을 위한 LIBS 소형화 장비 개발)

  • Jun, Hyung Min;Kim, Hyunwoo;Yoh, Jai-ick
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.2
    • /
    • pp.53-59
    • /
    • 2019
  • LIBS plug, a simplified laser-induced breakdown spectroscopy(LIBS) device with the purpose of measuring the fuel distribution inside the combustion chamber, was developed and manufactured. The LIBS plug receives only two wavelengths (H:656.3 nm, O: 777 nm) that are closely related to the equivalence ratio in the overall spectrum. The calibration curve between the signal of the LIBS plug and the equivalence ratio was constructed, and the fuel distribution of gasoline-air and LPG-air mixtures was measured using the LIBS plug.

Laser-Induced Plasma Spectroscopy Measurement on Surface Roughness in Surface Treatment of Titanium Alloys (티타늄 합금의 표면 처리에 있어 표면 거칠기에 대한 레이저 유도 플라즈마 분광분석법 측정 적용 연구)

  • Kim, Ji-Hun;Kim, Joohan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.9-17
    • /
    • 2020
  • In this study, the surface changes of titanium alloy using laser surface treatment and the surface analysis using laser-induced plasma spectroscopy were carried out. The laser surface treatment induced changes in surface roughness and the diffusion of atmospheric elements. Excessive melting or less melting caused roughness changes, but when moderate levels of energy were applied, a smoother surface could be obtained than the initial surface. In the process, the diffusion of atmospheric elements took place. To analyze the diffusion of atmospheric elements with respect to surface morphology, the surfaces were re-shaped with grinding. In this experimental conditions, the effect of plasma formation by surface roughness was identified. Compensated plasma signals for the material properties were obtained and analysed by removing the background plasma signal.

Development of in-situ Analysis System for Radwaste Glass Using Laser Induced Breakdown Spectroscopy (레이저유도 플라즈마분광법을 이용한 방사성폐기물 유리의 현장분석 시스템 개발)

  • 김천우;박종길;신상운;하종현;송명재;이계호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.137-146
    • /
    • 2004
  • Laser Induced Breakdown Spectroscopy(LIBS) system is being developed as an in-situ analysis system for the radioactive waste glass in the cold crucible melter. In order to complete the LIBS system, a spectrometer, a detector, and a laser were structured. An ESA 3000 (LLA Instruments GmbH, Germany) including a calibrated Kodak KAF-1001 CCD detector was selected as the spectrometer. A Q-switched Nd-YAG Brilliant(Quantel, France) laser was selected as an energy source. As the first research stage, the excitation temperatures of Fe(I) as a function of the detector's delay intervals(500, 1000, 1500, 2000ns) were evaluated using the Einstein-Boltzmann equation. The optimized excitation temperature of Fe (I) was 7820k at the delay time of 1500㎱ using the 532nm Nd-YAG laser pulse. This LIBS system will be optimized under the real environment vitrification facility in the near future and then used to be in-situ analyzed the glass compositions in the melter qualitatively.

  • PDF

Reaction Mechanism of Photo-Induced Etching of Single-Layer MoS2

  • Choe, Yu-Na;An, Gwang-Hyeon;Ryu, Sun-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.194.1-194.1
    • /
    • 2014
  • 기저면에 구조적 결함을 도입함으로써 그래핀과 $MoS_2$와 같은 이차원 결정의 물리, 화학, 전기 및 기계적 성질을 제어하려는 연구가 폭넓게 수행되고 있다. 본 연구에서는 플라즈마 속의 산소 래디컬을 이용하여 기계적 박리법으로 만들어진 단일층 그래핀과 $MoS_2$ 표면에 구조적 결함을 유도하고 제어하는 방법을 개발하였다. 라만 및 광발광 분광법을 통해 생성된 결함 밀도를 측정하고 전하 밀도 등의 화학적 변화를 추적하였다. 그래핀의 경우 산소 플라즈마 처리 시간에 따라 결함(defect)의 정도를 보여주는 라만 D-봉우리의 높이와 넓이가 커짐을 확인하였고 이를 G-봉우리의 높이와 비교하여 정량하였다. $MoS_2$의 경우 $E{^1}_{2g}$$A_{1g}$-봉우리의 높이가 점점 감소하고 광발광의 세기 또한 감소함을 확인하였다. 또한 본 연구에서는 기판의 편평도가 결함 생성 속도에 미치는 영향을 비교 및 분석하여 반응 메커니즘을 제시하고자 한다.

  • PDF

Characteristics of Laser-Induced Breakdown Spectroscopy (LIBS) at Space Environment for Space Resources Exploration (우주 자원 탐사를 위한 레이저 유도 플라즈마 분광분석법의 우주 환경에서의 특성 분석)

  • Choi, Soo-Jin;Yoh, Jai-Ick
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.346-353
    • /
    • 2012
  • The Laser-Induced Breakdown Spectroscopy (LIBS) has great advantages as an analytical technique, namely real-time analysis without sample preparation, ideal for mobile chemical sensor for space exploration. The LIBS plasma characteristics are strongly dependent on the surrounding pressure. In this study, seven types of target (C, Ti, Ni, Cu, Sn, Al, Zn) were investigated for their elemental lifetime. The target was located in vacuum chamber which has the pressure range of 760 to $10^{-5}$ torr. As the pressure is decreased, the elemental lifetimes of carbon and titanium declined, while all other targets showed increased lifetimes until reaching 1 torr and declined with continued pressure decrease. The boiling point and electronegativity amongst the physicochemical properties of the samples are used to explain this peculiarity.