• Title/Summary/Keyword: 레디믹스트 콘크리트(레미콘)

Search Result 15, Processing Time 0.017 seconds

레미믹스트 콘크리트 KS F 4009

  • 한국레미콘공업협회
    • 레미콘
    • /
    • no.1 s.90
    • /
    • pp.93-109
    • /
    • 2007
  • 본 자료는 산업자원부 기술표준원에서 2007. 7. 1일부터 적용 예정인 KS F4009(레디믹스트 콘크리트) 규격으로서 회원사 업무에 도움주고자 전문 게재합니다.(해설서 제외)

  • PDF

A Study on the Properties of Ready Mixed Concrete Quality in Site by Statistical Analysis (통계분석에 의한 현장 타설 콘크리트의 품질 특성에 관한 연구)

  • Ji, Suk-Won;Jung, Si-Jin;Seo, Chee-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.5
    • /
    • pp.171-180
    • /
    • 2007
  • The quality of ready-mixed concrete(henceforth abbreviated remicon) is influenced by various factors such as ingredient of material, difference of property, mixing ratio, mixing time, mixing error, conditioning of construction, method of curing and temperature, humidity time in transportation. These factors make it hard to confirm the quality of remicon till placing in site. As the quality control in field is very important to ensure the quality of building. Moreover in modern building production, the more important the inquiry of performance improvement, the more important the manufacture and the quality control of remicon. In this study, to examine and analyze the quality of remicon we used slump, air content and compressive strength in 7, 28 days as to remicon which placed during on year. As a result, we found that the slump and air content were satisfied with reference code and the compressive strength was more than the design standard strength so we concluded that the quality control of remicon was to be agreeable.

Characteristics of Concrete Using Ready-Mixed Concrete Recycled Water Mixed with Industrial By-Product Desulfurization Gypsum (산업부산물 탈황석고 혼입 레디믹스트콘크리트 회수수를 이용한 콘크리트의 특성)

  • Kim, Young-Yeop;Lee, Han-Seung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.395-403
    • /
    • 2020
  • CaO-based by-product, which consist of CaO, SO3, Al2O3 and so on, has being used to raw materials of CaO compound. When It was applied to recycling water of remicon, concrete performance can be enhanced because hydration reaction of powder material is accelerated. In this study, activated-sludge, which was putted desulfurization gypsum of CaO-based in recycling water, was manufactured to verify effect of them, and then they was investigated by characteristics of redy-mixde concrete. As a result of concrete tests, it was confirmed that there is no problem of strength or drying shrinkage while ensuring workability. Therefore, the possibility of specific application using activated sludge was confirmed.

Experimental Study on Unit Water Test of Ready Mixed Concrete (레디믹스트 콘크리트의 단위수량 시험에 관한 실험적 연구)

  • Kim, Young-Sun;Cho, Hong-Bum;Lee, Sang-Hyun;Ki, Jun-Do;Choi, Sung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.243-244
    • /
    • 2023
  • The quality of ready-mix concrete, a decisive factor in the performance of a structure, has recently been ensured by considering the unit water testing method, and this study experimentally examined the reliability of evaluation results based on this method.

  • PDF