• Title/Summary/Keyword: 디지털 방사선영상

Search Result 347, Processing Time 0.024 seconds

Patient Radiation Exposure Dose Evaluation of Whole Spine Scanography Due to Exposure Direction (Whole Spine Scanography의 검사방향에 따른 환자 선량 평가)

  • Kim, Jung-Su;Seo, Deok-Nam;Kwon, Soon-Mu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Whole spine scanography (WSS) is a radiological examination that exposes the whole body of the individual being examined to x-ray radiation. WSS is often repeated during the treatment period, which results in a much greater radiation exposure than that in routine x-ray examinations. The aims of the current study were to evaluate the patient dose of WSS using computer simulation, image magnification and angulation of phantom image using different patient position. We evaluated the effective dose(ED) of 23 consecutive patients (M : F = 13:10) who underwent WSS, based on the automatic image pasting method for multiple exposure digital radiography. The Anterior-Posterior position(AP) and Posterior-Anterior position( PA) projection EDs were evaluated based on the PC based Monte Carlo simulation. We measured spine transverse process distance and angulation using DICOM measurement. For all patient, the average ED was 0.069 mSv for AP position and 0.0361 mSv for PA position. AP position calculated double exposure then PA position. For male patient, the average ED was 0.089 mSv(AP) and 0.050 mSv(PA). For female patient, the average ED was 0.0431 mSv(AP) and 0.026 mSv(PA). The transverse process of PA spine image measured 5% higher than AP but angulation of transverse process was no significant differences. In clinical practice, just by change the patient position was conformed to reduce the ED of patient. Therefor we need to redefine of protocol for digital radiography such as WSS. whole spine scanography, effective dose, patient exposure dose, exposure direction. protocol optimization.

A Study of the Adjustment and Treatment Depending on the Change of Prostate Location Using DIPS in Proton Beam Therapy for Prostate Gland in which a Fiducial Gold Marker was Inserted (Fiducial Gold Marker가 삽입된 전립선암 양성자 치료 시 Digital Image Positioning System (DIPS)을 이용한 전립선의 위치변화에 따른 보정에 관한 연구)

  • Park, June-Ki;Kim, Sun-Young;Kim, Tae-Yoon;Choi, Kye-Sook;Yeom, Doo-Suk;Kang, Dong-Yoon;Choi, Seung-O;Park, Ji-Youn
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.25-29
    • /
    • 2008
  • Purpose: To monitor the changes of location of prostate gland using DIPS and to examine the adjustment and proton beam therapy depending on the movement of prostate gland in proton beam therapy for prostate gland in which a fiducial gold marker was inserted. Materials and Methods: This study was conducted in ten patients with prostate cancer who received proton beam therapy since April of 2008. To monitor the change of prostate location, three fiducial gold markers were inserted prior to the treatment. To minimize the movement of prostate gland, patients were recommended to urinate prior to the treatment, to intake a certain amount of water and to concomitantly undergo rectal balloon. In these patients, the set-up position was identical to that for a CT-simulation. The PA (posterior-anterior) and lateral images were obtained using both DIPS (digital image positioning system) and a plain radiography, and they were compared between the two imaging modalities. Thus, the changes of the location of fiducial gold marker were assessed based on three coordinates (x, y, z) and then adjusted. This was followed by proton beam therapy. Results: Images which were taken using a plain radiography were compared with those which were taken using DIPS. In ten patients, according to a reference bony marker, the mean changes of the location of fiducial gold marker based on an iso-center were X-axis: $\pm$0.116 cm, Y-axis: $\pm$0.19 cm and Z-axis: $\pm$0.176 cm. These ten patients showed a difference in the changes of location of prostate gland and it ranged between RT: 0.04 cm and RT: 0.24 cm on the X-axis; between Inf: 0.03 cm and Sup: 0.42 cm on the Y-axis; and Post: 0.05 cm and Ant: 0.35 cm on the Z-axis. Conclusion: To minimize the movement of prostate gland, as the pre-treatment prior to the treatment. In all the patients, however, three fiducial gold markers showed a daily variation which were inserted in the prostate gland. Based on the above data, Thus, the requirement of gold marker matching system depending on the daily variation in the proton beam therapy for which more accurate establishment of target was confirmed. It is assumed that an accurate effect of proton beam therapy would be enhanced by adjusting the target-center depending on the location change of prostate gland using DIPS which was used in the current study.

  • PDF

Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantom for Chest Digital Radiography (흉부 디지털 방사선 촬영 시 C-D phantom을 이용한 촬영조건에 따른 영상 평가)

  • Lee, In-Ja;Kim, You-Hyun;Kim, Chang-Nam;Lee, Chang-Yeob;Park, Kye-Yeon
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.25-32
    • /
    • 2009
  • To find out proper photographing conditions in the chest DR imaging, the evaluation of images using the C-D phantom was carried out on relationship of identification capability, graininess, and exposure ratio. The conclusions were obtained as follows. 1. The patient's entrance skin Exposure (ESE) was decreased as tube voltage was increased. 2. According to the tube voltage change, the C-D phantom's identification capability of the exposure conditions was most visible at 110 kVp. 3. The identification capability according to the exposure ratio (mAs) change was most visible at 90 kVp for 0.5 times of low exposure ratio and at 110 kVp for 1.5 times. Therefore, it is known that the images were able to be better identified at a high exposure than a low exposure. 4. The graininess according to the exposure ratio at tube voltage of 110 kVp resulted in the best thing at 1.5 times of ratio when the exposure ratio was 1.5 times increased and the tube voltage was changed, the graininess showed the best result at 110 kVp. Therefore, the patient's exposure dose was low when kVp was increased and the adequate kVp was found to be 110. The image was better identified when exposure ratio was 1.5 times compared to 1.0 times. The graininess was also good when the exposure ratio became 1.5 times. The tube voltage was good at 110 kVp. However, once the exposure ratio is increased, the amount of radiation dose that the patients received get increased, so that the exposure condition has to be thoroughly considered.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

Development of Quality Assurance Program for the On-board Imager Isocenter Accuracy with Gantry Rotation (갠트리 회전에 의한 온-보드 영상장치 회전중심점의 정도관리 프로그램 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.212-223
    • /
    • 2006
  • Positional accuracy of the on-board imager (OBI) isocenter with gantry rotation was presented in this paper. Three different type of automatic evaluation methods of discrepancies between therapeutic and OBI isocenter using digital image processing techniques as well as a procedure stated in the customer acceptance procedure (CAP) were applied to check OBI isocenter migration trends. Two kinds of kV x-ray image set obtained at OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ},\;270^{\circ}$ and every $10^{\circ}$ and raw projection data for cone-beam CT reconstruction were used for each evaluation method. Efficiencies of the methods were also estimated. If a user needs to obtain an isocenter variation map with full gantry rotation, a method taking OBI image for every $10^{\circ}$ and fitting with 5th order polynomial was appropriate. However for a mere quality assurance (QA) purpose of OBI isocenter accuracy, it was adequate to use only four OBI Images taken at the OBI source angle of $0^{\circ},\;90^{\circ},\;180^{\circ}\;and\;270^{\circ}$. Maximal discrepancy was 0.44 mm which was observed between the OBI source angle of $90^{\circ}\;and\;180^{\circ}$ OBI isocenter accuracy was maintained below 0.5 mm for a year. Proposed QA program may be helpful to Implement a reasonable routine QA of the OBI isocenter accuracy without great efforts.

  • PDF

Absorbed and effective dose in direct and indirect digital panoramic radiography (직.간접디지털 파노라마 방사선촬영시 흡수선량과 유효선량)

  • Lee, Gun-Sun;Kim, Jin-Soo;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.9-14
    • /
    • 2010
  • Purpose : We evaluated the absorbed doses to the organs and calculated the effective doses when using the digital panoramic radiography. Materials and Methods : The absorbed dose averages in major organs of oral and maxillofacial region were measured using the Dental head phantom (CIRS Co., USA), $^nLi_2B_4O_7$ TLD chip and UD-716AGL dosimeter (Matsushita Electric Industrial Co., JPN) when performing indirect and direct digital panoramic radiography. Effective doses were calculated from correspond to ICRP 2007 recommendations for two panoramic radiography. Results : The absorbed dose average on indirect and direct digital panoramic radiography was highest in parotid glands as measured 1259.6 mGy and 680.7 mGy respectively. Absorbed dose average in another organs were high in order of esophagus, submandibular gland, tongue and thyroid gland on both types of digital panoramic radiography. The absorbed dose average was higher on indirect type than direct one (p<0.05). The effective dose was higher on indirect type than direct one as measured 13.28 mSv and 8.70 mSv respectively. Conclusion : The absorbed doses in salivary gland and oral mucosa were high. However, thyroid gland also demands the attention on radiography due to high tissue weighting factor in spite of the low absorbed dose.

Assessment of apical root resorption using digital subtraction radiography (디지털공제방사선촬영술을 이용한 치근단 흡수의 평가)

  • Heo Min-Suk;Lee Sam-Sun;Lee Kyung-Hee;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries (CCD 디지털 방사선사진촬영법의 초기 치아우식증의 진단능 평가에 대한 연구)

  • Lee Wan;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.27-33
    • /
    • 2003
  • Purpose : The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. Materials and Methods : 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOV A test. Results: The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p > 0.05). Coclusion : These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  • PDF

Detection method of proximal caries using line profile in digital intra-oral radiography (디지털 구내방사선사진에서 라인 프로파일을 이용한 인접면우증식의 인지 방법)

  • Park, Jeong-Hoon;Choi, Yong-Suk;Kim, Gyu-Tae;Hwang, Eui-Hwan;Lee, Gi-Ja;Choi, Sam-Jin;Park, Hun-Kuk
    • Imaging Science in Dentistry
    • /
    • v.39 no.4
    • /
    • pp.185-189
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. Materials and Methods : The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Results : Mean values of D were $0.0354{\pm}0.0155$ in non-caries and $0.2632{\pm}0.0982$ in caries (p<0.001). Conclusion : The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  • PDF

The Comparison of Image Quality between Computed Radiography(CR) and Direct Digital Radiography(DDR) which Follows the Proper Exposure Conditions in General Photographing under the Digital Radiography(DR) (Digital Radiography 환경하에서 일반촬영시 적정 노출조건에 따른 CR과 DDR의 Image Quality 비교)

  • Kim, Jin-Bae;Kang, Chung-Hwan;Kang, Sung-Jin;Park, Soo-In;Park, Jong-Won;Kim, Yeong-Su;Kim, Seung-Sik
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.64-77
    • /
    • 2002
  • DR has had an important fact not only in the department of radiology but also in productivity or work efficiency of a whole hospital. The environment of DR has more various parameter than CR, so it is able to supply high quality of medical services. The current environment of radiology department in each hospital has been changed from Film-Screen system to DR through Full-PACS. This hospital which uses Full-PACS became to study the proper condition of CR and DDR and how the image quality of them is expressed among general photographing systems in the DR environment. From this experiment, the image quality of DDR is better than CR under the same exposure condition. And in the DDR system, the score of image which uses AEC is a little higher than the score which doesn't use it. Especially it can be known that the function of AEC of DDR is useful to improve the image quality in the part of skull and chest. (The function of AEC : It is the tool that detects the ionized current of x-ray which goes through objects with using the ion chamber which is in the detector. Also it controls the examination of X-ray when the proper density is reached.) Because the proper degree of density can be represented by this system, the photographing can be taken much easily without consideration of the exposure condition with the thickness of various objects. From the result of this experiment, it can be known that the selection of proper exposure condition plays an important rule to gain good Image Quality. More researches will be necessary about DDR system which has potential ability in the future.

  • PDF