• Title/Summary/Keyword: 디지털 방사선

Search Result 488, Processing Time 0.025 seconds

Study on the Image Quality Comparison between in Digital RT and Film RT (용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구)

  • Park, Sang-Ki;Ahn, Yean-Shik;Gil, Doo-Song
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.391-397
    • /
    • 2011
  • Conventional film radiographic test has been generally and widely used in the inspection on the weldment for quality assurance. On the other hand, since the analog RT is well known for typical time and cost consuming method with complex process of inspection, the industry has researched various ways how to improve radiographic test technology. In this study, we verified the fact that digital RT provides a lot more benefit in effectively detecting defects, ever film details, through digital processing of image enhancement, compared to film RT. As a result, we reached conclusion that digital RT is positively able to replace the film RT in industry in part or in whole.

Comparison of Direct Digital Radiography and Conventional Film Screen Radiography for Detection of Peritoneal Fluid in Dogs (개에서 복수의 평가에 있어서 필름-증감지 방사선 사진과 디지털 방사선 사진의 비교)

  • Choi, Ho-Jung;O, I-Se;Lee, Ki-Ja;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.18-22
    • /
    • 2012
  • This study was performed to evaluate the sensitivity of conventional film-screen radiography (CFSR) and direct digital radiography (DDR) for detection of various amounts of free peritoneal fluid. Ten adult male healthy beagles were used in this study. Radiographic examinations were performed in the right lateral and ventrodorsal positions. Fluid was injected in increments of 2.0 ml/kg of body weight up to 20.0 ml/kg of body weight. The images of CFSR and DDR were evaluated by two veterinary radiologists for evidence of abdominal fluid without knowledge of injected fluid volume. Data were evaluated by using the receiver operation curve (ROC) analysis and the area under the curve (AUC). There was no significant difference in detection of peritoneal fluid between DDR and CFSR in the ROC analysis. The accuracy of CFSR (0.805) was relatively higher than that of DDR (0.733), based on the ROC analysis and AUC. AUC of CFSR was higher in most injection doses. These results suggest that CFSR is more accurate than DDR for the detecting peritoneal fluid. Therefore, for situation in which digital radiographs are equivocal or small amount of fluid is suspected, other imaging modalities, such as ultrasonography would be helpful for determining the presence of fluids.

Digital imaging of film-based cephalograms using a digital camera (디지털 카메라를 이용한 필름 두부방사선사진의 디지털 이미지 전환)

  • Wang, Sung-Jin;Kim, Kyung-Ho;Choy, Kwang-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.5 s.106
    • /
    • pp.448-457
    • /
    • 2004
  • As computer Programs for cephalometric analysis were developed in diagnosis & treatment planning, digital imaging of film-based cephalograms came to be needed. When a digital camera is used, a problem encountered the image distortion produced according to the focal length, which causes errors in indentifying landmarks. In addition, changes in the image size and compression ratio will inevitably produce a low quality image, causing errors in identifying landmarks. Hence. we have found the focal length producing the least image distortion when digital imaging the film-based cephalograms and the minimal digital camera setting which helps to identify the correct landmarks using the COOLPIX4500 digital camera (Nikon, Japan). The results were as follows The image distortion was minimized at a focal length of 16.4mm (79.4mm when converted into a 35mm film camera) when digital imaging the film-based cephalograms. When wide imaging, with a focal length of under IS.4mm, barrel distortion was found and when tole imaging. with a focal length of over 15.4mm pincushion distortion was found. The minimal digital camera setting was $2272{\times}1704$ pixel at normal (1/8) compression from which we can identify the correct landmarks at the same level as tracing the film-based cephalograms manually. As a result. when digital imaging the film-based cephalograms, using a COOLPIX4500 digital camera (Nikon, Japan), the focal length should be 16.4mm the pixel image size over $2272{\times}1704$, and the compression ratio over normal (1/8).

Radiological Science Curriculum on the Digital Radiology Environments : Problems and Suggestions (디지털 방사선 환경에서의 방사선학과의 교육과정에 대한 현황과 개선 방향)

  • Kim, Chang-Soo;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.129-135
    • /
    • 2005
  • IT communication industries of current society are developed in enormous growth, our country leading the world in the number of super high speed internet equipments in use. In the pride oneself on communication network of those, mobile terminal technology and wireless phone production hold a high rank. Data communication and networking may be the fastest growing technologies in our culture today. In this way, IT fields conjugated in the daily quick, the fact that department of radiological science didn't discharged one's duties on current IT education. The curriculum of radiological technologists that play an important part between skill and occupation's education as major and personality didn't performed one's part most effectively on current IT environments and digital radiological equipments interface. Therefore, in this paper current curriculum of radiological science are catched hold of trend and problems on digital radiology environments, on fact the present state of problems, for radiological engineering and HIS manager, new curriculum course are suggested a reform measure of culture and major education curriculum introduction.

  • PDF

Comparison Research of SNR and SRb with Bright Calibration and Multi Frame Images in Digital Radiography of Welded Test Components (용접 시험편의 디지털 방사선 검사에서 밝기 교정과 중첩 영상에 따른 SNR 및 SRb 비교 연구)

  • Nam, Mun-Ho;Yang, Jin-Wook;Cho, Kap-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.731-739
    • /
    • 2021
  • This work compared the bright calibration of digital radiation with signal-to-noise ratio and basic spatial resolution according to multi frame to enable effective inspection of welding parts of structures at industrial sites. A total of 130 images were obtained by using a 75Se radiation source for flat weld test pieces and segmenting bright calibration and multi frame prior to shooting. The study confirms that the signal-to-noise ratio improves as the number of bright calibrations and the number of multi frame increases. The basic spatial resolution satisfied the baseline for both radiographic images. It was confirmed that the number of signal-to-noise ratio was similar by comparing images taken after installing lead shielding for scattering radiation. Although signal-to-noise ratio increases as multi frame increases, it is believed that good quality digital radiographs can be obtained if appropriate radiographic techniques are devised because exposure time of radiation affects workers' exposure and work efficiency.

Image Comparison of Curved and Flat Panel Detectors for the Application of Digital Radiography Testing in Pipe Welds (배관 원둘레 이음 용접부의 디지털 방사선 투과 검사 적용을 위한 커브드 및 평면형 검출기의 영상 비교)

  • Yang, Jin-Wook;Cho, Kap-Ho;Nam, Mun-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.585-594
    • /
    • 2022
  • The detector for digital radiography testing, which is currently mainly used, consists of a detector with a flat structure, making it impossible to fully adhere to the digital radiography testing of the test object with curvature. In this study, a curved panel detector capable of adhering to curvature was fabricated to improve the quality of the digital image during the digital radiography testing of piping welds at industrial sites, and digital radiography images using flat and curved panel detectors were obtained for 6in pipes with different nominal thickness. As a result of the experiment, it was confirmed that the flat panel detector does not fully adhere to the pipe, resulting in a gap between the outer part of the pipe and the detector, resulting in a difference in the unsharpness and diffusion of the digital image. On the other hand, it was confirmed that the curved panel detector minimizes the gap between the pipe outer part and the detector, so that digital image diffusion is less than that of the flat panel detector. The higher the confidence of the image, the lower the quality and error in reading, so it is believed that higher quality images can be obtained than conventional flat panel detectors when using detectors that can be closely attached to the inspection object.

The Legal Protection of Digital Medical Imaging in U-healthcare (U-헬스케어에 있어서 디지털 의료영상정보의 법률적 보호)

  • Jeong, Young-Yeub
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.7 no.1
    • /
    • pp.23-31
    • /
    • 2005
  • 원격진료 홈네트워크 아파트 진료용 키오스크 모바일주치의 등으로 대표되는 U-헬스케어에 있어서 기초가 되는 것은 의료정보를 디지털화해서 전자적 자료의 형태로 저장 보관하고 이를 송 수신할 수 있는 기술이라고 할 수 있다. 우리나라의 경우, U-Korea 전략의 하나로 보건복지부가 주축이 되어 2005년 10월 현재 국가보건의료정보화계획(ISP)을 수립하기 위한 작업을 추진중에 있다. 여기서, 예컨대 임상병리검사소견이나 방사선촬영소견 등의 의료정보가 전자적 장치에 의해 디지털화 할 경우 디지털 의료정보가 되는 것이며, 이 가운데 특히 방사선촬영소견 등 방사선분야의 모든 촬영기록이 PACS시스템을 통해 기재되거나 저장 전송될 경우 이를 디지털 의료영상정보라고 할 수 있다. 그런데 오늘날 정보통신기술의 발달로 말미암아 디지털 의료영상정보를 포함한 디지털의료정보는 대량적으로 수집 저장되고 유통 내지 공동활용이 보편화되어 감에 따라 그 의료정보의 보호에 관한 문제가 중요한 이슈로 대두되고 있다. 결론적으로 말하자면, 이러한 디지털 의료영상정보가 전자의무기록(EMR) 형태로 저장 보관되는 경우 이는 전자의무기록에 관한 법률규정이 적용되어 법률적 보호를 받게 되며, 그 보호의 강도는 종래 오프라인 상의 의료정보 보호보다 한층 강화된 규정을 두고 있다. 이와 같은 흐름에 있어서 최근 정부가 국가보건의료정보화계획 수립과 함께 제정작업을 추진하고 있는 가칭 의료정보화촉진 및 개인정보보호에 관한 법률(안)은 시사점이 크다고 보기 때문에 소개하고자 한다.

  • PDF

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.

The Effect of Splinting with Concomitant Root Planing;Clinical and Digital Subtraction Radiographic Study (치근활택술과 스프린트 병행처치의 효과에 관한 연구;디지털 공제 촬영술을 이용한 임상적 연구)

  • Lee, Ji-Young;Kye, Seung-Bum;Kim, Won-Kyoung;Lee, Yong-Moo;Ku, Young;Ryu, In-Chul;Chung, Chong-Pyoung;Choi, Sang-Mook;Han, Soo-Boo
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.1
    • /
    • pp.207-227
    • /
    • 2001
  • 스프린트는 치주처지료에서 부가적 처치법으로 널리 사용되고 있으며, 한편, 디지털 공제 활영술은 기존방사선촬영술의 한계점을 극복하기 위해 기발된 새로운 방법이다. 이번 연구에서는 치근활택술 단독시행시와 스피린트 병행 처치시의 효과를 임상적, 방사선학적으로 비교하였다. 중정도의 성인성 치주염을 가진 20명의 환자를 대상으로 하되 10명은 치근활택술 단독으로, 나머지 10명은 스프린트 병행처치로 처치하였다. 임상적, 방사선학적인 평가는 처치전, 처치후 6개월에 행하고, 임상적 평가의 경우 3개월에 추가로 실시하였다. 이번 연구에서 사용된 임상 지수로는 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상부착수준, 임상부착증가, 탐침시출혈, 치아동요도 등이며, 방사선학적 평가는 기존 방사선촬영술에 의한 방법과 디지털 공제촬영수렝 의한 방법으로 행하였다. 디지털 공제 촬영술에 의한 평가시, 영상은 Digora 프로그램에 의해 획득하고 Emago 프로그램으로 처리 하여 다음과 같은 결론을 얻었다. 1. 처치후 3개월에 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상적부착수준, 탐침시 출혈 등의 임상지수들이 변했으며, 특히 이러한 변화는 치주낭깊이, 치은퇴축, 탐침시출혈에서 유의성이 있었다. ( p<0.05 ) 그러나 두군간 차이는 인정되지 않았다. ( p>0.05 ) 2. 처치후 6개월에도 치태지수, 치은지수, 치은퇴축, 치주낭깊이, 임상적부착수준, 탐침시출혈, 치아동요도 등의 임상지수들이 변했으며, 특히 이러한 변화는 치주낭깊이, 치은퇴축, 탐침시출혈, 치태지수, 치아동요도에서 유의성이 있었다. ( p<0.05 ) 그러나 두 군간 차이는 인정되지 않았다. ( p>0.05 ) 3. 켄달 상관분석시, 임상적 평가와 기존 방사선 촬영술에 의한 평가사이의 관련성을 낮았으며 거의 0에 가까운 수치를 보였으며 (r=0.110, p=0.639 ) 임상적 평가와 디지털 공제 방사선 촬영술에 의한 평가사이에서 약간 높은 관련성을 보였다. ( r=0.257, p=0.315 ) 즉 치주치료후의 골변화는 디지털 공제 방사선 촬영술에 의한 평가시 기존 방사선 사진보다 임상적 부착증가와 더욱 긴밀한 관련성을 보여준다. 이상의 결과로 볼 때, 스프린팅 처치는 치주 치료에 있어 치근활택술에 부가적 표과를 제공하지 못한다.

  • PDF

Evaluation of Clinical Application Model of Optimized Parameter through Analysis of Stability of Radiation Output and Image Quality when Exposure Time Change of Digital Radiography (DR) (디지털 방사선 시스템(DR)의 조사시간 변화 시 방사선 출력과 영상 화질의 안정성 분석을 통한 최적화된 파라미터의 임상 적용 모델 평가)

  • Hwang, Jun-Ho;Choi, Ji-An;Kim, Hyun-Soo;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.139-148
    • /
    • 2020
  • The purpose of this study is to propose a method to optimize the performance of Digital Radiography (DR) by analyzing the effect of exposure time change on the stability of radiation output and image quality. The experimental method was used to change the exposure time to 50 msec, 100 msec, 200 msec, and 400 msec so that the Percentage Average Error (PAE), Time-to-Radiation Dose Curve, Signal to Noise Ratio (SNR), Contrast to Noise Ratio (CNR) and theses analysis were performed to evaluate the normal operation of parameters, radiation output and image quality. As a result, all the parameters used in the experiment showed the Percentage Average Error in the normal range, and the shorter the exposure time, the stability of radiation output and image quality decrease. In conclusion, it was found that the performance of Digital Radiography can be optimized when stable radiation output and image quality are applied by applying 100 msec ~ 200 msec exposure time.