• Title/Summary/Keyword: 등요

Search Result 169,185, Processing Time 0.163 seconds

Case study of Music & Imagery for Woman with Depression (우울한 내담자를 위한 MI(Music & Imagery) 치료사례)

  • Song, In Ryeong
    • Journal of Music and Human Behavior
    • /
    • v.5 no.1
    • /
    • pp.67-90
    • /
    • 2008
  • This case used MI techniques that give an imagery experience to depressed client's mental resource, and that makes in to verbalism. Also those images are supportive level therapy examples that apply to positive variation. MI is simple word of 'Music and Imagery' with one of psychology cure called GIM(Guided Imagery and Music). It makes client can through to the inner world and search, confront, discern and solve with suitable music. Supportive Level MI is only used from safety level music. Introduction of private session can associate specification feeling, subject, word or image. And those images are guide to positive experience. The First session step of MI program is a prelude that makes concrete goal like first interview. The Second step is a transition that can concretely express about client's story. The third step is induction and music listening. And it helps to associate imagery more easily by used tension relaxation. Also it can search and associate about various imagery from the music. The last step is process that process drawing imagery, talking about personal imagery experience in common with therapist that bring the power by expansion the positive experience. Client A case targets rapport forming(empathy, understanding and support), searching positive recourse(child hood, family), client's emotion and positive support. Music must be used simple tone, repetition melody, steady rhythm and organized by harmony music of what therapist and client's preference. The client used defense mechanism and couldn't control emotion by depression in 1 & 2 sessions. But the result was client A could experience about support and understanding after 3 sessions. After session 4 the client had stable, changed to positive emotion from the negative emotion and found her spontaneous. Therefore, at the session 6, the client recognized that she will have step of positive time at the future. About client B, she established rapport forming(empathy, understanding and support) and searching issues and positive recognition(child hood, family), expression and insight(present, future). The music was comfortable, organizational at the session 1 & 2, but after session 3, its development was getting bigger and the main melody changed variation with high and low of tune. Also it used the classic and romantic music. The client avoids bad personal relations to religious relationship. But at the session 1 & 2, client had supportive experience and empathy because of her favorite, supportive music. After session 3, client B recognized and face to face the present issue. But she had avoidance and face to face of ambivalence. The client B had a experience about emotion change according depression and face to face client's issues After session 4. At the session 5 & 6, client tried to have will power of healthy life and fairly attitude, train mental power and solution attitude in the future. On this wise, MI program had actuality and clients' issues solution more than GIM program. MI can solute the issue by client's based issue without approach to unconsciousness like GIM. Especially it can use variety music and listening time is shorter than GIM and structuralize. Also can express client's emotion very well. So it can use corrective and complement MI program to children, adolescent and adult.

  • PDF

Evaluation of the Fruit Quality Indices during Maturation and Ripening and the Influence of Short-term Temperature Management on Shelf-life during Simulated Exportation in 'Changjo' Pears (Pyrus pyrifolia Nakai) (배 신품종 '창조'의 성숙 중 품질 요인 변화 및 수송온도 환경에 따른 반응성)

  • Lee, Ug-Yong;Choi, Jin-Ho;Ahn, Young-Jik;Chun, Jong-Pil
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.378-385
    • /
    • 2017
  • In this study, we evaluated the changes of fruit quality indices during fruit development and ripening in Korean new pear cultivar 'Changjo', developed from a cross between 'Tama' and '81-1-27' ('Danbae' ${\times}$ 'Okusankichi') in 1995 and named in 2009, to determine appropriate harvest time and to enhance the market quality and broaden the cultivation area. The fruits of 'Changjo' pears harvested from 132 days after full bloom (DAFB) to 160 DAFB. Fruit growth and quality indices were monitored at 1 week interval by measuring fruit weight, length, diameter, firmness, and taste related quality indices. The calculated fruit fresh weight increased continuously with fruit development and reached to an average of 594g on Sep. 20 (160 DAFB). The ratio of length to diameter declines as fruit maturation progress, resulting in 0.898 for ripe fruit stage as a round oblate shape. Flesh firmness of 'Changjo' pears showed over 30N until 153 DAFB and then decreased abruptly with fruit ripening, reaching a final level of about 26.44N on 160 DAFB. Starch content of fruit sap was also decreased abruptly after 146 DAFB which decreased almost half of the fruits harvested at 139 DAFB. In parallel with the decrease of flesh firmness, ethanol insoluble solids (EIS) content decreased sharply with fruit ripens, only 50% of EIS was detected on the fruits harvested on 160 DAFB when compared to that of the fruits harvested on 139 DAFB (Aug. 30). The maximum value of soluble solids contents was observed in the fruits harvested on 153 DAFB, resulting in $14.2^{\circ}Brix$. The changes of skin color difference $a^*$ which means loss of green color occurred only after 139 DAFB, coincide with the decrease of SPAD value of the fruit skin. The sugars of the 80% ethanol soluble fraction consisted mainly of fructose, sorbitol, glucose and sucrose, also increased during maturation and ripening. Fructose and sucrose contents were larger than those of glucose and sorbitol in flesh tissues. These results were explained that stored starch is converted to soluble sugars during fruit maturation, mainly in fructose and sucrose increasing the sweetness of this cultivar. Total polyphenols were increased up to middle of fruit maturation (146 DAFB) and then decreased continuously until the end of fruit maturation. Consequently, our results suggested that the commercial harvest time of 'Changjo' pears should not be passed 153 DAFB and late harvest of this cultivar would not good for quality maintenance during shelf-life. As a result of the post-harvest low-temperature acclimation experiment during the short-term transportation period, fruits harvested at 146 DAFB tended to maintain higher firmness after 14 days of simulated marketing at $25^{\circ}C$ compared to fruits harvested at 153 DAFB regardless of temperature set. And, the slower the rate of decrease to the final transport temperature of $5^{\circ}C$, the higher the incidence of internal browning and ethylene production. Therefore, in order to suppress the physiological disorder and to maintain the fruit quality when exporting to Southeast Asia in the 'Chanjo' pears, it is desirable to lower the temperature of the fruits within a short time after harvest and to set the harvest time before 146 days after full bloom.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

The Role of Control Transparency and Outcome Feedback on Security Protection in Online Banking (계좌 이용 과정과 결과의 투명성이 온라인 뱅킹 이용자의 보안 인식에 미치는 영향)

  • Lee, Un-Kon;Choi, Ji Eun;Lee, Ho Geun
    • Information Systems Review
    • /
    • v.14 no.3
    • /
    • pp.75-97
    • /
    • 2012
  • Fostering trusting belief in financial transactions is a challenging task in Internet banking services. Authenticated Certificate had been regarded as an effective method to guarantee the trusting belief for online transactions. However, previous research claimed that this method has some loopholes for such abusers as hackers, who intend to attack the financial accounts of innocent transactors in Internet. Two types of methods have been suggested as alternatives for securing user identification and activity in online financial services. Control transparency uses information over the transaction process to verify and to control the transactions. Outcome feedback, which refers to the specific information about exchange outcomes, provides information over final transaction results. By using these two methods, financial service providers can send signals to involved parties about the robustness of their security mechanisms. These two methods-control transparency and outcome feedback-have been widely used in the IS field to enhance the quality of IS services. In this research, we intend to verify that these two methods can also be used to reduce risks and to increase the security protections in online banking services. The purpose of this paper is to empirically test the effects of the control transparency and the outcome feedback on the risk perceptions in Internet banking services. Our assumption is that these two methods-control transparency and outcome feedback-can reduce perceived risks involved with online financial transactions, while increasing perceived trust over financial service providers. These changes in user attitudes can increase the level of user satisfactions, which may lead to the increased user loyalty as well as users' willingness to pay for the financial transactions. Previous research in IS suggested that the increased level of transparency on the process and the result of transactions can enhance the information quality and decision quality of IS users. Transparency helps IS users to acquire the information needed to control the transaction counterpart and thus to complete transaction successfully. It is also argued that transparency can reduce the perceived transaction risks in IS usage. Many IS researchers also argued that the trust can be generated by the institutional mechanisms. Trusting belief refers to the truster's belief for the trustee to have attributes for being beneficial to the truster. Institution-based trust plays an important role to enhance the probability of achieving a successful outcome. When a transactor regards the conditions crucial for the transaction success, he or she considers the condition providers as trustful, and thus eventually trust the others involved with such condition providers. In this process, transparency helps the transactor complete the transaction successfully. Through the investigation of these studies, we expect that the control transparency and outcome feedback can reduce the risk perception on transaction and enhance the trust with the service provider. Based on a theoretical framework of transparency and institution-based trust, we propose and test a research model by evaluating research hypotheses. We have conducted a laboratory experiment in order to validate our research model. Since the transparency artifact(control transparency and outcome feedback) is not yet adopted in online banking services, the general survey method could not be employed to verify our research model. We collected data from 138 experiment subjects who had experiences with online banking services. PLS is used to analyze the experiment data. The measurement model confirms that our data set has appropriate convergent and discriminant validity. The results of testing the structural model indicate that control transparency significantly enhances the trust and significantly reduces the risk perception of online banking users. The result also suggested that the outcome feedback significantly enhances the trust of users. We have found that the reduced risk and the increased trust level significantly improve the level of service satisfaction. The increased satisfaction finally leads to the increased loyalty and willingness to pay for the financial services.

  • PDF

Trend and Forecast of the Medical Care Utilization Rate, the Medical Expense per Case and the Treatment Days per Cage in Medical Insurance Program for Employees by ARIMA Model (ARIMA모델에 의한 피용자(被傭者) 의료보험(醫療保險) 수진율(受診率), 건당진료비(件當診療費) 및 건당진료일수(件當診療日數)의 추이(推移)와 예측(豫測))

  • Jang, Kyu-Pyo;Kam, Sin;Park, Jae-Yong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.441-458
    • /
    • 1991
  • The objective of this study was to provide basic reference data for stabilization scheme of medical insurance benefits through forecasting of the medical care utilization rate, the medical expence per case, and the treatment days per case in medical insurance program for government employees & private school teachers and for industrial workers. For the achievement of above objective, this study was carried out by Box-Jenkins time series analysis (ARIMA Model), using monthly statistical data from Jan. 1979 to Dec. 1989, of medical insurance program for government employees & private school teachers and for industrial workers. The results are as follows ; ARIMA model of the medical care utilization rate in medical insurance program for government employees & private school teachers was ARIMA (1, 1, 1) and it for outpatient in medical insurance program for industrial workers was ARIMA (1, 1, 1), while it for inpatient in medical insurance program for industrial workers was ARIMA (1, 0, 1). ARIMA model of the medical expense per case in medical insurance program for government employees & private school teachers and for outpatient in medical insurance program for industrial workers were ARIMA (1, 1, 0), while it for inpatient in medical insurance program for industrial workers was ARIMA (1, 0, 1). ARIMA model of the treatment days per case of both medical insurance program for government employees & private school teachers and industrial workers were ARIMA (1, 1, 1). Forecasting value of the medical care utilzation rate for inpatient in medical insurance program for government employees & private school teachers was 0.0061 at dec. 1989, 0.0066 at dec. 1994 and it for outpatient was 0.280 at dec. 1989, 0.294 at dec. 1994, while it for inpatient in medical insurance program for industrial workers was 0.0052 at dec. 1989, 0.0056 at dec. 1994 and it for outpatient was 0.203 at dec. 1989, 0.215 at 1994. Forecasting value of the medical expense per case for inpatient in medical insurance program for government employees & private school teachers was 332,751 at dec. 1989, 354,511 at dec. 1994 and it for outpatient was 11,925 at dec. 1989, 12,904 at dec. 1994, while it for inpatient in medical insurance program for industrial workers was 281,835 at dec. 1989, 293,973 at dec. 1994 and it for outpatient was 11,599 at dec. 1989, 11,585 at 1994. Forecasting value of the treatment days per case for inpatient in medical insurance program for government employees & private school teachers was 13.79 at dec. 1989,13.85 at an. 1994 and in for outpatient was 5.03 at dec. 1989, 5.00 at dec. 1994, while it for inpatient in medical insurance program for industrial workers was 12.23 at dec. 1989, 12.85 at dec. 1994 and it for outpatient was 4.61 at dec. 1989, 4.60 at 1994.

  • PDF

Leukocyte count and hypertension in the health screening data of some rural and urban residents (일부 농촌과 도시의 건강선별조사 자료로 본 백혈구수와 고혈압과의 관계)

  • Lee, Choong-Won;Yoon, Nung-Ki;Lee, Sung-Kwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.24 no.3 s.35
    • /
    • pp.363-372
    • /
    • 1991
  • We used the health screening data of some rural and urban residents to examine the cross-sectional association between leukocyte count and hypertension. The 206 male and 203 female rural residents were selected by multi-stage cluster sampling method in Kyungsan-Kun area of Kyungbuk province in 1985 and 600 urban residents were selected by the same sampling method as the rural residents in Daegu city of the same province in 1986 compatible with age-sex distribution of Daegu city of 1985 census, but of whom 384 actually responded. The rest of 600 were replaced by age and sex with those who were members of the medical insurance plan visiting the health management department of the university hospital to get the biannual preventive medical checkups. Excluded in the analysis were those having hypertensive history, diseases and extreme outlying values of the screening tests, leaving 373 rural and 571 urban residents. Leukocyte count was measured with ELT-8 Laser shadow method and the unit $cells/mm^3$, Blood pressures were determined with an aneroid sphygmomanometer with pre-standardized method and hypertensives were defined as those showing systolic blood pressure more than 140mmHg and/or diastolic blood pressure more than 90mmHg. Total residents pooled (N=944) showed a significant difference between hypertensives and normotensives ($6965.93{\pm}1997.01\;vs\;6490.61{\pm}1941.32,\;P=0.00$) and in rural residents was noted the similar significant difference (P=0.03). None of significant differences were noted in any stratum stratified by residency and sex. Compared to the lowest quintile of WBC, 2/5 quintile showed odds ratio 0.99 (95% Confidence interval, Ci 0.62-1.59), 3/5 quintile 1.41 (95% CI 0.90-2.21), 4/5 quintile 1.76 (95% CI. 1.14-2.72), and highest quintile 1.80 (1.15-2.82) in the total residents. Likelihood ratio test for linear trend for it indicated a significant trend ($X^2_{trend}=5.53,\;df=1,\;P<0.05$). There were no other significant odds ratios compared to the lowest quintile of WBC in strata stratified by residency and sex. The odds ratios in total residents which had showed significant odds ratios became nonsignificant and of reduced magnitude after controlling age, frequency of smoking and drinking with multiple logistic. regression. In each stratum, it changed magnitudes of odds ratios slightly and unstably. None of the trend tests showed any significant trend. These results suggest that the Friedman et al's finding of association between leukocyte count and hypertension may be due to an statistical type I error resulting from the data dredging in an exploratory study, in which more than 800 variables were screened as possible predictors of hypertension.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

Factors Related to Serum Level of Carbohydrate Antigen 19-9 and Cancer Antigen 125 in Healthy Rural Populations in Korea (일부 농촌지역 주민에서 혈청 CA19-9 및 CA125 농도에 영향을 미치는 인자에 관한 연구)

  • Lee, SK;Yoo, KY;Park, SK;Kang, DH;Kim, JQ;Chung, JK;Lee, MC
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.71-80
    • /
    • 1998
  • This study examines the levels of carbohydrate antigen 19-9(CA19-9) and cancer antigen 125(CA125) in serum and its related factors in healthy Korean population. Although CA19-9 and CA125 have been widely used tumor markers for gastroenteric cancers and ovarian cancer in Western countries, there are no information available on the serum levels of CA19-9 and CA125 in healthy population and the factors affecting the levels of these tumor markers in Korea. A cross-sectional study was performed to measure CA19-9 and CA125 among 76 healthy males and 95 healthy females in Korea. CA19-9 and CA125 were quantitated using solid-phase radioimmunoassay kits. Informations on the factors which might be related to the levels of these markers were collected by questionnaire(e.g., smoking, alcohol consumption, menstruation, oral pill use, breast-feeding history, etc.). There was no statistically significant difference in the mean of CA19-9 concentration between men(10.4 u/ml) and women(10.1 u/ml), whereas the mean of CA125 levels(11.2 u/ml) was higher in women than that(2.5 u/ml) in men. Although there was a statistically significant association between CA19-9 and average number of cigarette consumed per day(r=0.59, p=0.026) and total number of cigarettes consumed in women(r=0.74, p=0.003), the significance disappeared by multiple regression analysis after adjusting age and body mass index. Later age of menopause(p=0.035) and longer duration of breast-feeding(p=0.050) were significant predictors for CA125 levels in women by multiple regression analysis after adjusting age and body mass index. In conclusion, CA19-9 can be used as a stable tumor marker in clinical practices, however, menstruation and breast-feeding should be considered when CA125 is used in women.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF