• Title/Summary/Keyword: 도시캐노피모델

Search Result 8, Processing Time 0.021 seconds

Evaluation of the Urban Heat Island Intensity in Seoul Predicted from KMA Local Analysis and Prediction System (기상청 국지기상예측시스템을 이용한 서울의 도시열섬강도 예측 평가)

  • Byon, Jae-Young;Hong, Seon-Ok;Park, Young-San;Kim, Yeon-Hee
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.135-148
    • /
    • 2021
  • The purpose of this study was to evaluate the urban heat island (UHI) intensity and the corresponding surface temperature forecast obtained using the local data assimilation and prediction system (LDAPS) of the Korea Meteorological Administration (KMA) against the AWS observation. The observed UHI intensity in Seoul increases during spring and winter, while it decreases during summer. It is found that the diurnal variability of the UHI intensity peaks at dawn but reaches a minimum in the afternoon. The LDAPS overestimates the UHI intensity in summer but underestimates it in winter. In particular, the model tends to overestimate the UHI intensity during the daytime in summer but underestimate it during the nighttime in winter. Moreover, surface temperature errors decrease in summer but increase in winter. The underestimation of the winter UHI intensity appears to be associated with weak forecasting of urban temperature in winter. However, the overestimated summer UHI intensity results from the underestimation of the suburban temperature forecast in summer. In order to improve the predictability of the UHI intensity, an urban canopy model (MORUSES) that considers urban effects was combined with LDAPS and used for simulation for the summer of 2017. The surface temperature forecast for the city was improved significantly by adopting MORUSES, and there were remarkable improvements in urban surface temperature morning forecasts. The urban canopy model produced an improvement effect that weakened the intensity of the UHI, which showed an overestimation during summer.

A Study on Urban Tree Canopy Artificial Intelligence Model for Carbon Neutrality in the Face of Climate Crisis (기후 위기에 맞서 탄소중립을 위한 도시 나무 캐노피 인공지능 모델 연구)

  • Jung, Jisun;Kim, Kyungbaek
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.529-531
    • /
    • 2022
  • 기후 위기가 대두되며 탄소중립에 많은 관심이 쏟아지고 있다. 탄소중립을 실천하기 위한 여러 가지 방법 중 도시의 수목을 관리하는 것은 탄소배출 저감, 대기질 개선 등의 환경적인 긍정적 효과를 얻을 수 있다. 수종별 온실가스 흡수량과 흡수 계수에는 차이가 있지만 도시 나무 캐노피를 증가시키면 온실가스 흡수량도 증가한다. 본 논문은 탄소정보공개 프로젝트(CDP)에서 제공하는 데이터를 기반으로 도시의 녹지 지대를 구글 지도(Google Map) 위성사진을 통해 찾아내고 지니 계수(Gini Coefficient)를 통해 도심 녹지 균형을 비교하였다. 향후 도시 수목과 녹지 데이터를 축적해 기초자료가 쌓이면 도시환경의 지표로 활용될 수 있을 것으로 기대된다.

Quantitative Study on the Effect of the Building Composition on the Urban Thermal Environment (건물군 조건이 도시 열환경에 미치는 영향에 관한 정량적 검토)

  • Yeo, In-Ae;Yoko, Kamata;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.180-183
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate was analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1)The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. (2)Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature.

  • PDF

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

Numerical Simulation on the Effect of the Land Coverage Change on the Urban Heat Budget (토지피복 변화가 도시열수지에 미치는 영향에 관한 수치시뮬레이션)

  • Kim, Sang-Ok;Yeo, In-Ae;Ha, Kyung-Min;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.176-179
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed using 3-Dimensional Urban Canopy Model. The characteristics of urban thermal environment was analyzed by classifying land coverage and increasing natural land coverage ratio. The results are as follows. The characteristics of the land coverage on urban thermal environment formation can be summarized by the effects like higher temperature on the artificial coverage, and the contrary effects on the natural coverage. When the water coverage 100% was made up, maximum temperature was declined by $5.5^{\circ}C$, humidity by the 6.5g/kg, wind velocity by 0.6m/s, convective sensible heat by $400W/m^2$ and the evaporative latent heat was increased by $370W/m^2$ compared to when artificial coverage 100% was formed. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analysing urban climate phenomenon.

  • PDF

A Study of the Urban Tree Canopy Mean Radiant Temperature Mitigation Estimation (도시림의 여름철 평균복사온도 저감 추정 연구)

  • An, Seung Man;Son, Hak-gi;Lee, Kyoo-Seock;Yi, Chaeyeon
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.1
    • /
    • pp.93-106
    • /
    • 2016
  • This study aimed to estimate and evaluate the thermal mitigation of the urban tree canopy on the summer outdoor environment by quantitative use of mean radiant temperature. This study applied the SOLWEIG model based $T_{mrt}$ comparison method by using both (1) urban tree canopy presence examples and (2) urban tree canopy absence examples as constructed from airborne LiDAR system based three-dimensional point cloud data. As a result, it was found that an urban tree canopy can provide a decrease in the entire domain averaged daily mean $T_{mrt}$ about $5^{\circ}C$ and that the difference can increase up to $33^{\circ}C$ depending both on sun position and site conditions. These results will enhance urban microclimate studies such as indices (e.g., wind speed, humidity, air temperature) and biometeorology (e.g., perceived temperature) and will be used to support forest based public green policy development.

A Study on High-resolution Numerical Simulation with Detailed Classification of Landuse and Anthropogenic Heat in Seoul Metropolitan area (수도권지역의 지표이용도 및 인공열 상세적용에 따른 고해상도 수치실험 연구)

  • Lee, Hankyung;Jee, Joon-Bum;Min, Jae-Sik
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.19 no.4
    • /
    • pp.232-245
    • /
    • 2017
  • In this study, the high-resolution numerical simulation results considering landuse characteristics are analyzed by using single layer Urban Canopy Model (UCM) in Weather Research Forecast (WRF). For this, the impact of urban parameters such as roughness length and anthropogenic heat in UCM is analyzed. These values are adjusted to Seoul metropolitan area in Korea. The results of assessment are verified against observation from surface and flux tower. Forecast system equipped with UCM shows an overall improvement in the simulations of meteorological parameters, especially temperature at 2 m, surface sensible and latent heat flux. Major contribution of UCM is appreciably found in urban area rather than non-urban. The non-urban area is indirectly affected. In simulated latent heat flux, applying UCM is possible to simulate the change similarly with observations on urban area. Anthropogenic heat employed in UCM shows the most realistic results in terms of temperature and surface heat flux, indicating thermodynamic treatment of UCM could enhance the skills of high resolution forecast model in urban and non-urban area.

Development and Evaluation of Urban Canopy Model Based on Unified Model Input Data Using Urban Building Information Data in Seoul (서울 건물정보 자료를 활용한 UM 기반의 도시캐노피 모델 입력자료 구축 및 평가)

  • Kim, Do-Hyoung;Hong, Seon-Ok;Byon, Jae-Yong;Park, HyangSuk;Ha, Jong-Chul
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.417-427
    • /
    • 2019
  • The purpose of this study is to build urban canopy model (Met Office Reading Urban Surface Exchange Scheme, MORUSES) based to Unified Model (UM) by using urban building information data in Seoul, and then to compare the improving urban canopy model simulation result with that of Seoul Automatic Weather Station (AWS) observation site data. UM-MORUSES is based on building information database in London, we performed a sensitivity experiment of UM-MOURSES model using urban building information database in Seoul. Geographic Information System (GIS) analysis of 1.5 km resolution Seoul building data is applied instead of London building information data. Frontal-area index and planar-area index of Seoul are used to calculate building height. The height of the highest building in Seoul is 40m, showing high in Yeoido-gu, Gangnam-gu and Jamsil-gu areas. The street aspect ratio is high in Gangnam-gu, and the repetition rate of buildings is lower in Eunpyeong-gu and Gangbuk-gu. UM-MORUSES model is improved to consider the building geometry parameter in Seoul. It is noticed that the Root Mean Square Error (RMSE) of wind speed is decreases from 0.8 to 0.6 m s-1 by 25 number AWS in Seoul. The surface air temperature forecast tends to underestimate in pre-improvement model, while it is improved at night time by UM-MORUSES model. This study shows that the post-improvement UM-MORUSES model can provide detailed Seoul building information data and accurate surface air temperature and wind speed in urban region.