• Title/Summary/Keyword: 데드 존

Search Result 29, Processing Time 0.028 seconds

Deadzone compensation of a XY table using fuzzy logic (XY 테이블의 퍼지 데드존 보상)

  • 장준오
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.17-28
    • /
    • 2004
  • A deadzone compensator is designed for a XY positioning table using fuzzy logic. The classification property of fuzzy logic systems makes them a natural candidate for the rejection of errors induced by the deadzone, which has regions in which it behaves differently. A tuning algorithm is given for the fuzzy logic parameters, so that the deadzone compensation scheme becomes adaptive, guaranteeing small tracking errors and bounded parameter estimates. Formal nonlinear stability proofs are given to show that the tracking error is small. The fuzzy logic deadzone compensator is implemented on a XY positioning table to show its efficacy.

FL Deadzone Compensation of a Mobile robot (이동로봇의 퍼지 데드존 보상)

  • Jang, Jun Oh
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.4
    • /
    • pp.191-202
    • /
    • 2013
  • A control structure that makes possible the integration of a kinematic controller and a fuzzy logic (FL) deadzone compensator for mobile robots is presented. A tuning algorithm is given for the fuzzy logic parameters, so that the deadzone compensation scheme becomes adaptive, guaranteeing small tracking errors and bounded parameter estimates. Formal nonlinear stability proofs are given to show that the tracking error is small. The fuzzy logic deadzone compensator is implemented on a mobile robot to show its efficacy.

NN Saturation and FL Deadzone Compensation of Robot Systems (로봇 시스템의 신경망 포화 및 퍼지 데드존 보상)

  • Jang, Jun-Oh
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.187-192
    • /
    • 2008
  • A saturation and deadzone compensator is designed for robot systems using fuzzy logic (FL) and neural network (NN). The classification property of FL system and the function approximation ability of the NN make them the natural candidate for the rejection of errors induced by the saturation and deadzone. The tuning algorithms are given for the fuzzy logic parameters and the NN weights, so that the saturation and deadzone compensation scheme becomes adaptive, guaranteeing small tracking errors and bounded parameter estimates. Formal nonlinear stability proofs are given to show that the tracking error is small. The NN saturation and FL deadzone compensator is simulated on a robot system to show its efficacy.

  • PDF

Dead Zone Correction for Abundance Estimation of Demersal Fish by Acoustic Method (저서어자원량의 음향추정에 있어서 해저 데드존의 보정에 관한 연구)

  • 황두진
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.3
    • /
    • pp.202-209
    • /
    • 2000
  • In order to estimate demersal fishes using acoustic echo sounders and echo integrators, we consider several problems that are accurate bottom detection, optimum bottom offset and dead zone. The dead zone where no fish detection are summed distance resolution by the half pulse length of transmitted pulse and beam angle above the seabed. This paper has considered the dead-zone correction method to be technically correct for survey of demersal fishes. A comparison between near-bottom SV profiles acquired in Funka Bay, Hokkaido, of Japan, the East China Sea and the Yellow Sea, of Korea, with before and after the bottom correction, shows that the SV obtained with after the bottom correction is 2∼3dB higher than before the bottom correction in Funka Bay, and 17dB higher in East China Sea, too.

  • PDF

Design of a Variable Structure Speed Controller having a Dead Zone Switching layer for the Sinusoidal type Brushless DC Motor (데드 존 스위칭 영역을 갖는 정현파형 브러시리스 직류전동기의 가변구조 속도제어기 설계)

  • 김세일;최중경;박승엽
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.639-650
    • /
    • 1999
  • In this paper, a chattering alleviation VSS controller for the sinusoidal type BLDC motor is designed. Dead Zone function is proposed to change the chattering occurring in the transient state from high frequency to low frequency and time-varying gains are applied for the control input to eliminate the steady state excessive chattering in the conventional ISM. The proposed Dead Zone function represents the sliding layer composed of two switching surfaces and if a state vector exists in this layer, the chattering don't occur. Simulation and experimental results confirm the useful effects of the above algorithm.

  • PDF

A High Speed and Low Jitter PLL Clock generator (고속 저잡음 PLL 클럭 발생기)

  • Cho, Jeong-Hwan;Chong, Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.3
    • /
    • pp.1-7
    • /
    • 2002
  • This paper presents a new PLL clock generator that can improve a jitter noise characteristics and acquisition process by designing a multi-PFD(Phase Frequency Detector) and an adaptive charge pump circuit. The conventional PLL has not only a jitter noise caused from such a demerit of the wide dead zone and duty cycle, but also a long delay interval that makes a high speed operation unable. An advanced multi-structured PFD circuit using the TSPC(True Single Phase Clocking) circuit is proposed, in which it shows an excellent functionalities in terms of the jitter noises by designing its circuit with the exact dead zone and duty cycle. Our new designed adaptive charge pump in the loop filter of a PLL can improve an acquisition characteristic by adaptively increasing of current. The Hspice simulation is done to evaluate the performance of the proposed circuit. Simulation result shows that our PLL has under 0.01ns in the dead zone, no influence from the duty cycle of input signals and under 50ns in the acquisition time. This circuit will be able to be used in develops of high-performance microprocessors and digital systems.  

Improvement of the Response Characteristics Using the Fuzzy-PLL Controller (퍼지-PLL 제어기를 이용한 응답특성 개선)

  • Cho, Jeong-Hwan;Seo, Choon-Weon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.175-181
    • /
    • 2005
  • This paper proposes the fuzzy-PLL control system for fast response time and precision control of automation systems. The conventional PLL has not only a jitter noise caused from such a demerit of the wide dead zone, but also a long delay interval that makes a high speed operation unable. In order to solve the problems, the proposed system, which provides the improvement in terms of the control region in high speed and precision control, first used the fuzzy control method for fast response time and when the error reaches the preset value, used the PLL method designing new PFD for precision control. The new designed multi-PFD improves the dead zone, jitter noise and response characteristics, which is consists of P-PFD(Positive edge triggered PFD) and N-PFD(Negative edge triggered PFD) and can improve response characteristics to increase PFD gain.

Hybrid Adaptive Controller Improving The Jitter Noise (지터 잡음을 개선한 하이브리드 적응제어기)

  • Cho, Jeong-Hwan;Hong, Kwon-Eui;Ko, Sung-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.108-114
    • /
    • 2009
  • This paper proposes the new hybrid adaptive controller for fast response time and precision control of automation system which exist deadzone or non-linearity of system. The proposed system, which provides the improvement in terms of the control region in high speed and precision control, first used the fuzzy control method for fast response time and when the error reaches the preset value, used the PLL method designing PFD improved jitter for precision control. The new designed PFD improves the jitter noise and response characteristic without generating deadzone. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerably improved performance in the position control of automation system.

Improvement on resolution of mono-filament wire (초음파 팬텀 내 모노필라멘트의 해상력 개선에 대한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.49-56
    • /
    • 2003
  • The purposes of this study are to improve the ultrasound resolution of various nylon and metallic mono-filament wires, therefore, it was tested that it analyze on nylon mono-filament wire of 0.1 mm in A Co.'s ultrasonic phantom and synthesis of C15 g tissue mimicking materials(TMM), analyze resolution of nylon and metallic mono-filament wires in water and TMM. The results obtained were summarized as follows: 1. Metallic mono-filament wire of 0.1 mm and nylon mono-filament wire of 0.12 mm, 180 denier showed that it cleared dot echo pattern. 2. Metallic and nylon mono-filament wire of 0.2 mm showed that it cleared comet tail echo by reverberation artifact. 3. Nylon and metallic mono-filament wire of 0.1 mm showed that it can used for dead zone and axial resolution test. 4. Nylon mono-filament wire compared with metallic mono-filament wire showed that it satisfy elasticity and construction. 5. Degree of hardness of na not changed mono-filament's echo textures.

  • PDF