• Title/Summary/Keyword: 덕트장치

Search Result 81, Processing Time 0.034 seconds

Conceptual Study and Design Ideas for SUAV Propulsion System (스마트무인기 신개념추진시스템 개념연구)

  • 전용민;정용운;양수석
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.19-26
    • /
    • 2003
  • In this paper, the result of the conceptual study of a tipjet driven propulsion system is presented. The concept of a tipjet driven propulsion system is to employ tipjet as power source to drive a rotor Because the vehicle is supposed to takeoff and land vertically, a rotor system, which has tipjet nozzles, is adopted to fly like a helicopter. Exhaust gas, which is generated by an engine, Passes through an internal duct system and divided into four blade ducts. The design code is consists of two parts, engine model and internal duct model. Inside a rotating duct, compressible flow is affected by two additional force terms, centrifugal force and coriolis force and they govern the performance in rotary mode, The intention of this paper is to address the issues associated with sizing and optimizing configurations of a tipjet driven propulsion system especially in rotary wing mode.

Image Processing Method using Color Lines on Overlay Robot for Glass Fiber Pipe/Duct Joint (유리섬유 배관/덕트 조인트 접합 로봇의 주행 및 공정을 위한 색상 실선의 영상처리)

  • Baek, J.H.;Jeong, M.S.;Jang, M.W.;Hong, S.H.;Seo, K.H.;Suh, J.H.;Lee, G.S.;Lee, J.Y.
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.1090-1093
    • /
    • 2019
  • 유리섬유강화복합재료로 제작된 배관/덕트 조인트의 오버레이 자동접합을 할 수 있는 로봇이 개발되고 있으며 로봇의 구성 중 하나인 자동적층장치의 작업 시작 위치와 제자리 회전 오차를 극복할 수 있는 기준선에 대한 실시간 영상처리가 필요하다. 기존의 선 검출 알고리즘들은 연산량이 많아 실시간 처리가 어렵거나 전체 영상에서 잡음에 취약한 단점이 있다. 본 논문은 이러한 FRP 배관 및 덕트 내 색상 실선 인식 알고리즘의 효율적인 실시간 영상처리 방법에 관하여 소개하고 배관 내 라인 제어를 위한 선의 실제 거리를 계산하고 출력하는 방법을 나타내었다.

Development of active noise control ventilation tube (능동 소음 제어 통풍관의 개발)

  • Ha, Sang-Mo;Park, Seung-Kyu;Ahn, Ho-Kyun;Yoon, Tae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1815-1816
    • /
    • 2006
  • 소음은 환경 오염원의 하나로서 사람에게 육체적, 정신적 피해를 발생시킨다. 이에 소음 제어 기술의 필요성이 증대하였고, 그 중에서 제어가 까다롭고 고비용을 요구하는 저주파 소음 제어 기술의 개발이 확대되고 있다. 따라서 본 연구에서는 저주파의 주기적인 특성을 가지는 1차원 평면파 소음에 대한 능동 제어를 위해 기존의 적응 피드포워드 방법의 단점을 보완하는 적응 피드백 방법을 이용한 능동 소음 제어 시스템을 구성하고 능동 소음 제어 실험을 수행하였다. 이를 위해 소음원과 제어 음원을 가지는 덕트 형상의 실험 장치를 구성하였다. 제어기 설계를 위해 전파 소음을 예측하는 선형 예측법을 적용한 적응 디지털 필터를 구성하였으며 적응 알고리즘으로 Filtered-X LMS 알고리즘을 이용하였다. 제어기는 제어 알고리즘을 프로그램화하여 DSP에 입력함으로써 구성하였다. 실험에 사용된 소음은 500[Hz] 이하의 단일 주파수의 정현파 소음을 사용하였으며, 실험결과 음압 감소의 효과를 볼 수 있었다. 능동 소음 제어의 기술을 개발하여 하드웨어(덕트)의 모양 및 구조, 제어기의 종류 및 처리 속도, 주파수나 크기와 같은 특성이 급격히 변하는 소음의 경우에 능동적으로 소음을 제어할 수 있으며, 저주파 소음을 발생시키는 관형 연소기와 같은 장치 및 여러 분야에 응용이 가능하도록 하였다.

  • PDF

Configuration of sensor array for in-duct mode detection (덕트 내 모드 분석을 위한 센서 배치에 관한 연구)

  • Jeong W.;Lee S.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.239-242
    • /
    • 2004
  • 터보팬엔진등에서 발생하는 음장의 특징은 지배적인 음향모드 구조를 가진다는 점이다. 이러한 구조를 파악 해내는 것은 소음원을 찾아내고 그 소음원의 전파를 규명하여 소음을 저감하는데 중요한 기여를 할 수 있다. 음향모드의 검출을 위해서 많은 연구가 이루어져 왔으며 센서의 이용방식에 따라 원음장에서의 측정법, 회전형 갈퀴 (rotating rake)를 이용한 측정법, 덕트내 벽면에 센서를 분포시키는 측정법으로 나눌 수 있다. 이중 벽면에 센서를 위치시키는 방법은 다른 방법에 비해 빠르게 측정결과를 얻을 수 있으며 측정장치가 간단하다는 장점이 있다. 본 연구에서는 기존에 이 방법의 단점으로 여겨져 왔던 많은 수의 센서를 줄이는 새로운 센서 배치에 대해 기술하였으며 측정하고자 하는 주파수에 존재하는 전체 모드의 개수와 비교하여 최소한의 센서 개수를 설명하였다.

  • PDF

Experimental Study of Power Generation Performance of Small-Scale Thermoelectric System (소규모 산업 폐열회수용 열전발전시스템의 출력 특성에 관한 실험적 연구)

  • Chung, Jae-Hoon;Kim, Woo-Chul;Lee, Jin-Ho;Yu, Tae-U
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.4
    • /
    • pp.383-390
    • /
    • 2010
  • In this study, a thermoelectric power generation system was constructed for a waste-heat recovery. Thermoelectric modules were attached to a stainless steel duct, and a hot air blower was set such that it faced the duct inlet. We found that to achieve the maximum power out of the system, the temperature in the hot side of the thermoelectric module should be uniform. The optimum compressive pressure exerted on the module was observed. Further, the thermoelectric power performance was evaluated using the heat sink attached to the cold side of the thermoelectric module. In particular, when using a natural-convection heat sink, the power output difference is approximately five times.

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building (고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰)

  • Yoon, Sung-Min;Seo, Jung-Min;Kim, Yang-Soo;Lee, Joong-Hoon;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

High Bit Rate Image Coder Using DPCM based on Sample-Adaptive Product Quantizer (표본 적응 프러덕트 양자기에 기초한 DPCM을 이용한 고 전송률 영상 압축)

  • 김동식;이상욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12B
    • /
    • pp.2382-2390
    • /
    • 1999
  • In this paper, we employed a new quantization scheme called sample-adaptive product quantizer (SAPQ) to quantize image data based on the differential pulse code modulation (DPCM) coder, which has fixed length outputs and high bit rates. In order to improve the performance of traditional DPCM coders, the scalar quantizer should be replaced by the vector quantizer (VQ). As the bit rate increases, it will be nearly impossible to implement a conventional VQ or modified VQ, such as the tree-structured VQ, even if the modified VQ can significantly reduce the encoding complexity. SAPQ has a form of the feed-forward adaptive scalar quantizer having a short adaptation period. However, since SAPQ is a structurally constrained VQ, SAPQ can achieve VQ-level performance with a low encoding complexity. Since SAPQ has a scalar quantizer structure, by using the traditional scalar value predictors, we can easily apply SAPQ to DPCM coders. For synthetic data and real images, by employing SAPQ as the quantizer part of DPCM coders, we obtained a 2~3 dB improvement over the DPCM coders, which are based on the Lloyd-Max scalar quantizers, for data rates above 4 b/point.

  • PDF

A Study on the Typology and the Characteristics of the Architectural Zenithal Opening -Focused on the Inflow Methods of the Zenithal Light- (천창의 유형및 특성에 관한 연구 -빛의 유입 방법을 중심으로-)

  • Ryu, Joohi;Kim, Young-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5619-5626
    • /
    • 2015
  • The zenithal light is the one that is entered down into the interior space or the spaces such as the inner court, through windows high located in the wall or openings of the roof. The aim of this study is to analyze the types of mechanism for the zenithal light by studying some examples related to the zenithal opening, and to investigate those characteristics. One of the most important features is a structural unit of the skylight entering the room. In this study, according to the structural unit, the direct light type, the duct-type and the shade type was distinguished, and each type can be divided into several modified types. Precisely, the direct light type is divided into an unexposed type and an exposed type of the source of light. The duct type is also divided into an intensive duct type and a distributed duct type. The shade type is classified into a ceiling surface shade, a reflections objet shade, a double ceiling shade and a wall shade.

Design and Numerical Analysis of Swirl Generator in Internal Duct using Delta Wing with Vortex Flap (와동 플랩 삼각날개를 이용한 관내 와류 발생장치 설계 및 수치해석)

  • Kim, Myung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.761-770
    • /
    • 2007
  • In this study, a swirl generator using delta wing was developed in order to simulate total pressure distortion and flow angle distortion. The delta wing was used for $65^{\circ}$-degree sweep back angle to satisfy the design performance for vortex core position, total pressure distortion(DC90) and swirl angle. To extend the swirling flow area, a $45^{\circ}$-degree vortex flap have applied to the delta wing. The swirl generator satisfied the design requirement of distortion coefficient in the flow distortion test to be applied to the simulation duct, and the performances of distortion for vortex core position and swirl angle using CFD(computational fluid dynamics) analysis results that was verified by flow distortion test results.