• Title/Summary/Keyword: 덕트장치

Search Result 81, Processing Time 0.027 seconds

Mechanical Isolation Method for an Air Intake Duct with Vertical Temperature Gradient (수직 온도구배를 갖는 공기 흡입 덕트의 기계적 격리기법)

  • Jung, Chihoon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.87-93
    • /
    • 2016
  • In a Direct Connect(DC) mode altitude engine test, a labyrinth seal is set up between an air intake duct and an engine. The labyrinth seal plays a key role in mechanically isolating them, which contributes to the accurate measurement of thrust and the other component forces. However, when high vertical temperature gradient is generated in the supplied air in the duct, the isolation breaks down. In this paper, a labyrinth seal control device is designed and installed in an effort to eliminate the issue. Test result shows the device successfully gets rid of the contact problem even when high vertical temperature gradient is produced.

A Study on Modeling of Test Result Management Components based on Software Product Line (소프트웨어 제품계열 기반의 성적관리 컴포넌트 모델링에 관한 연구)

  • Kim Su-Youn;Kim Haeng-Kon;Kim Sung-Won
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2004.05a
    • /
    • pp.269-272
    • /
    • 2004
  • 콤포넌트 가변성 장치를 이용하면 사용자가 용도에 알맞게 기능을 특화할 수 있다. 프로덕트 라인은 다양하고 빠르게 변화하는 시장의 요구사항과 특정 도메인 영역에 속하는 애플리케이션간의 재사용 가능한 아키텍처 및 컴포넌트의 구성으로부터 연관된 시스템 구축 시 생산성과 품질의 향상을 제공함으로써 현재 많은 관심의 초점이 되고 있다. 프로덕트 라인에서 컴포넌트 내부에 공통으로 사용할 워크프롤로를 가지고 있어 컴포넌트 사용자는 Sequence Diagram등을 통해 메시지 흐름을 직접 구현할 필요가 없다. 재사용 가능한 아키텍처는 많은 변화 계획들과 메커니즘을 포함하고 있다. 하지만, 아키텍처를 설계하기 위한 아키텍처에서의 변화성 관리에 대한 명확한 방법이 미흡하다. 따라서 본 논문에서는 재사용 가능한 아키텍처를 설계하기 위해 변화성의 명확한 표현과 아키텍처에서의 적절한 위치를 식별하기 위해, 다양한 변화성 타입을 정의하고, 프로덕트 라인 아키텍처상의 컴포넌트 설계의 변화성을 표현하고, 다중 뷰의 모델링을 통하여 프로덕트 라인의 다양한 측면을 제시하고, 사례연구로 성적관리 컴포넌트 모델링에 적용해 보고자 한다.

  • PDF

Inception of Tip Vortex Cavitation on Ducted Rotors (덕트 로터의 날개끝 보오텍스 캐비테이션 초기발생특성)

  • K.S. Kim;K.Y. Kim;J.W. Ahn;J.T. Lee;E.D. Park;H.B. Chae;H.S. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.1
    • /
    • pp.37-46
    • /
    • 1999
  • The influence of the tip clearance upon the cavitation inception were investigated by experiments for ducted rotors having different tip clearances The axial and tangential mean velocities around the ducted rotors were measured using an L.D.V. system to investigate the correlation between tip vertex cavitation inception and hub vortex cavitation. Observation results for tip vortex cavitation and hub vortex cavitation show good agreement in trend with the analysis results of velocity measurement. An optimum tip clearance for ducted rotor was selected to delay the tip vortex cavitation.

  • PDF

Numerical Prediction of Chamber Performance for OWC Wave Energy Converter (OWC 파력발전장치의 공기실 성능예측에 대한 수치적인 연구)

  • Jin, Ji-Yuan;Hyun, Beom-Soo;Liu, Zhen;Hong, Key-Yong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.91-98
    • /
    • 2010
  • The water elevation inside the air chamber and bi-directional air flow in the duct of Oscillating Water Column wave energy converter is one of the most important factors to evaluate the operating performance. The numerical wave tank based on the commercial software Fluent 6.2 in the present paper is employed to generate the incident waves. The numerical wave tank consists of the continuity equations, the Reynolds-averaged Navier-Stokes equations and the two-phase VOF function. The oscillating amplitude of water column in the chamber and bi-directional air flow in the duct installed on the top of the chamber are calculated, and compared with experimental data to verify the validation of the present NWT. The nozzle effects of the chamber-duct system on the relative amplitudes of the inner free water surface and air flow rate in the duct are investigated.

Experimental equipment for high efficiency heat pump development by CFD (CFD를 통한 고효율 히트펌프 개발을 위한 실험장치)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.5
    • /
    • pp.1402-1408
    • /
    • 2020
  • In order to save energy, a lot of research has been conducted to develop a high-efficiency heat pump. Research to reduce or eliminate the occurrence of frost in the outdoor unit coil is also being conducted at the same time. A constant temperature chamber was constructed that allows experimentation under the same conditions as in the natural state so that frost does not occur in the outdoor unit of the heat pump regardless of the season. In order to verify the validity of the experimental apparatus, a simulation was conducted by dividing the straight length of the duct in front of the outdoor unit in the constant temperature chamber, which is the experimental apparatus, into three conditions. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Effect of Growing Part Following Local Heating for Cherry Tomato on Temperature Distribution of Crop and Fuel Consumption (방울토마토 생장부 추종 국소난방이 군락 온도분포 및 연료소비에 미치는 영향)

  • Kwon, Jin Kyung;Kang, Geum Chun;Moon, Jong Pil;Lee, Tae Seok;Lee, Su Jang
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.217-225
    • /
    • 2015
  • Local heating system providing hot air locally to growing parts including shoot apex and flower cluster which were temperature-sensitive organs of cherry tomato was developed to reduce energy consumption for greenhouse heating without decline of crop growth. Growing part following local heating system was composed of double duct distributer which connected inner and outer ducts with hot air heater and winder which moved ducts up and down following growing parts with plant growth. Growing part local heating system was compared with conventional bottom duct heating system with respect to distributions of air and leaf surface temperatures according to height, growth characteristics and energy consumption. By growing part local heating, air temperature around growing part was maintained $0.9{\sim}2.0^{\circ}C$ higher than that of lower part of crop and leaf surface temperature was also stratified according to height. Investigations on crop growth characteristics and crop yield showed no statistically significant difference except for plant height between bottom duct heating and growing part local heating. As a result, the growing part local heating system consumed 23.7% less heating energy than the bottom duct heating system without decrease of crop yield.

Numerical Analysis and Experimental Investigation of Duct Flows of an MHD Propulsion System (사각형의 MHD 추진 덕트 내부유동에 관한 수치해석 및 실험적 연구)

  • J.W. Lee;S.J. Lee;C.M. Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.32 no.1
    • /
    • pp.83-93
    • /
    • 1995
  • A numerical and experimental investigation on the flow characteristics in the rectangular duct of an MHD propulsion system has been carried out. In numerical analysis, three-dimensional, steady-state, viscous, incompressible electrically conducting fluid flow under the influence of uniformly applied magnetic and electric fields was treated using a finite-difference technique. It was found from the numerical study that when the Lorentz force is weak, the typical parabolic velocity profile under a laminar flow condition changes to an M shaped profile near the electrode region and that the pressure increases linearly from the inlet toward the outlet of the MHD duct under constant electro-magnetic field. In experiment, thrust of the MHD propulsion system can be controlled easily by varying electrode current. The measured pressure gradient along the MHD duct is proportional to the Lorentz force, which is in agreement with the numerical results.

  • PDF

CFD on the possibility of performance evaluation of heat pump outdoor unit in duct-type constant temperature chamber (덕트형 항온챔버에서 히트펌프 실외기의 성능평가 가능성에 대한 CFD)

  • Kim, Jong-Ryeol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.116-121
    • /
    • 2021
  • A lot of research is being done to develop a high-efficiency heat pump to save energy, and research to reduce or eliminate the phenomenon of frost occurring in the outdoor unit coil is also being conducted at the same time. A curved constant temperature chamber was constructed that can be tested under the same conditions as in the natural state so that the research can be conducted in which frost does not occur on the outdoor unit of the heat pump regardless of the season. Simulations were performed to verity whether such a curved constant temperature chamber has feasibility as an experimental device. For CFD conditions, the length of the straight duct in front of the outdoor unit located in the duct-type constant temperature chamber was 1, 5, 10 and 15 times the diameter of the duct. As a result, it was found that a straight space must be secured 10 times the diameter of the duct.

Pressure drop and heat transfer characteristics of a flat-plate solar collector with heat transfer enhancement device (열전달 향상 장치에 따른 평판형 태양열 집열기의 압력강하 및 열전달 특성)

  • Ahn, Sung-Hoo;Shin, Jee-Young;Son, Young-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.453-460
    • /
    • 2013
  • The surface roughness and heat transfer enhancement devices are known to increase the performance of a flat plate soar collector. This study includes the experiments on the effect of the several heat transfer enhancement devices inserted in duct to simulate the flat-plate solar collector. Experiment was basically at a constant heat flux on the upper duct wall. Inserted heat transfer enhancement devices are Chamfered rib $10^{\circ}$, Chamfered rib $20^{\circ}$, Rib & Groove and Rib & Dimple. Reynolds number is in the range of 2,300 to 22,000 which corresponds to turbulent regime. With the heat transfer enhancement devices, heat transfer would increase by the secondary flow and the increase of the heat transfer area. Pressure drop also increases with the insertion of the enhancement devices. Rib & Dimple model is the best in heat transfer enhancement, however, Chamfered rib $10^{\circ}$ model is the lowest in the pressure drop. Considering the heat transfer enhancement simultaneously with low pressure drop increase, performance factor was the best for the Chamfered rib $10^{\circ}$.