• Title/Summary/Keyword: 대동맥 판막, 수술

Search Result 223, Processing Time 0.029 seconds

Pulmonary Autograft with Right Ventricular Outflow Tract Reconstruction in Swine model -1, Feasibility of REV operation- (돼지를 이용한 대동맥 판막에서 자가 폐동맥 판막 이식 및 우심실 유출로 형성술의 신술식 개발 -제1보 REV술식의 적합성 연구-)

  • 안재호;노윤우
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.822-827
    • /
    • 1996
  • Ross procedure is an ideal operative modality for diseased aortic valve especially in children, but homogrart for right ventricular outflow tract(RVOT) reconstruction is not easily available in Korea. We tried to perform REV procedure for RVOT reconstruction in 10 young piglets(15.3 $\pm$ 1.3 kg) In an attempt to e clude the use of homograft in Ross operation. 3 of them survived after operation and raised till adult pig(about 70 kg), then examined their pulmonary arteries and hearts. Without any stenotic residues in the great arteries, we only found the deformed monocusp patch with severe calcification, which deprived the adequate valve function, but kept the pig growing normally We are sure that this operative modality (REV + Ross procedure) could be extendedly applied to the diseased human aortic valve, but we need to develope the anti-calcification method for the heterograft patch.

  • PDF

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Papillary Fibroelastoma of the Aortic Valve: Discovered by Chance with Intraoperative Transesophageal Echocardiography - A case report - (수술실 내 경식도 심장초음파검사에서 우연히 발견된 유두상 섬유탄력종 - 1예 보고 -)

  • Kim, Jeong-Won;Jung, Jong-Pil;Park, Soon-Eun;Kim, Young-Min;Park, Chang-Ryul;Shin, Je-Kyoun
    • Journal of Chest Surgery
    • /
    • v.40 no.9
    • /
    • pp.637-640
    • /
    • 2007
  • Papillary fibroelastoma is a rare benign cardiac tumor with an elevated risk for embolization and most papillary fibroelastomas do not cause symptoms. In this report, we describe a case of previous undiagnosed masses of the aortic valve that were incidentally found on intraoperative transesophageal echocardiography during coronary artery bypass surgery. Upon surgery, masses were found on the left and right aortic cusps and the pathological findings were consistent with a papillary fibroelastoma.

Giant Pseudoaneurysm of Ascending Aorta complicating Recurrent Mediastinitis after Gardiac Surgery (반복된 종격동염 치료후 상행 대동맥에 발생한 거대 가성 대동맥류)

  • Kang, Jun-Gyu;Lee, Chul-Ju;Hong, Jun-Wha;Choi, Ho;So, Dong-Mun;Tak, Seung-Jae
    • Journal of Chest Surgery
    • /
    • v.34 no.3
    • /
    • pp.252-255
    • /
    • 2001
  • 본 30세 여환은 류마치스성 심장판막질환 진단하네 승모판막 및 대동맥판막 치환술 시행후 종격동염 발생하여 지속적 종격동 세척 및 3주간의 항생제 치료후 퇴원하였다. 외래 추적중 다시 감염 및 염증소견 보여 입원하여 혈액배양검사와 흉부전산화 단층촬영시행하였다. 검사상 종격동염의 이후 3주간의 항생제 치료에도 염증 소견이 지속되어 다시 시행한 흉부 전산화단층촬영상 상행대동맥에 거대 가성대동맥류소견보여 재개흉술을 시행하여 초저체온 완전 순환정지 하에 가성대동맥류를 절제한 후, 우심낭편을 이용하여 대동맥 성형술을 시행하였다. 수술후 환자는 순조롭게 회복하였으며 현재 외래에서 추적관리하고 있다.

  • PDF

Early Clinical Experience in Valve Replacement Using On-X Prosthetic Heart Valve (On-X 기계판막을 이용한 판막치환술의 단기성적분석)

  • 김인섭;김우식;신용철;유환국;김병열;정성철
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.742-748
    • /
    • 2004
  • The On-X valve was recently introduced. It was the aim of this study to assess the safety and feasibility from the data derived from 28 patients who underwent aortic and/or mitral valve replacement with this prosthesis in National Medical Center. Material and Method: From May 1999 and May 2003, a series of 28 consecutive patients who had been implanted with 32 On-X prosthesis were reviewed, The operative procedure comprised of 12 MVR, 10 AVR and 6 DVR. The study followed the guidelines of AATS/STS. Mean follow-up was 27 months (total 04 patient-years). Result: Early ($\leq$30 days) mortality was 7.44% (2/28) and no late mortality occurred in the study. Total actuarial freedom from mortality at 2 years was 92.86$\pm$4.87% for all cases, 100% for MVR, 90$\pm$9.49% for AVR, and 83.3$\pm$1.52% for DVR. Thromboembolic event occurred in 2 MVR patients and that was the only complication; therefore, the linearized incidence of valve related complications was 3.17%/ patient-years for all cases and 6.5%/patient-years for MVR and the actuarial freedom from valve related complications at 2 years was 84.85$\pm$10.75%. Preoperatively, 24 (85.71%) patients were in NYHA functional class III or IV but postoperatively, 25 (89,29%) patients were in NYHA functional class I or II. The levels of hemoglobin, hematocrit, serum LDH, reticulocyte rate and indirect bilirubin were all within normal range at postoperative 3 month. In mitral position, the peak gradient was 6.1$\pm$1.8 mmHg and the mean gradient was 3.0$\pm$0.6 mmHg and EOA were 2.54$\pm$0.56 $m^2$, 2.39$\pm$0.73 $m^2$, 2.34$\pm$0.55 $m^2$, 2.40$\pm$0.63 $m^2$ at 27 mm, 29 mm, 31 mm, 33 mm respectively. In aortic postion, the peak gradient was 21.1 $\pm$14.12 mmHg and the mean gradient was 12.3$\pm$6.52 mmHg. Conclusion: Since there was no significant difference in the postoperative mortality, valve related complications and echocardiographic hemodynamic data compared to standard bileaflet design and since there was an improvement in the NYHA functional class and normal values of hemolytic indicators, it can be assumed that On-X valve is safe and feasible. However, accumulation of cases and long-term follow-up of this patient group is needed to establish this result.

Clinical Analysis of Reoperation for Prosthetic Valve Replacement Report of 12 cases (인공판막 치환수술 재수술에 대한 임상적 고찰 -12예보고-)

  • 장진우;이연재
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.390-395
    • /
    • 1997
  • Between May 1986 and May 1996, 269 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 70 cases and mechanical valve was replaced in 232. Of this 12 patients performed reoperations for replacement, and the mean interval between primary valve operation and reoperation was 87.6 months for mitral valve and )7.7 months for aortic valve. There were 10 women and 2 me , agcd from 22 to 68 years(mean 45). A bioprosthetic valve was implanted in 8 cases and a mechanical valve was implanted in 4 cases for initial operation. llidications for reoperation were structural deterioration in 5 cases(42%), valve thrombus in 5 cases(42%) and endocarditis in 2 cases(17%). Operations performed included 3 aortic valve replacements(25%), 9 mitral valve replacements(75%). Wc used mechanical valve in llcases(92%) and tissue valve in 1 case(8%) for reoperation. There were 2 early operative deaths because of valve detachment and of acute respiratory failure. Among ten survivor's, there were no late deaths with follow up of 35.8 months.

  • PDF

Ascending Aortic Dissection Late After Aortic Valve Replacement (대동맥 판막 치환술 후 만기에 발생한 상행 대동맥 박리증)

  • 오정훈;이동협;이정철;정태은;이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.630-633
    • /
    • 2001
  • Central anticholinergic syndrome is defined as an absolute or relative reduction in cholinergic activity in the central nervous system and has a wide variety of manifestations. It is associated with almost any drug given during anesthesia, except neuromuscular relaxants, and treated with the cholinesterase inhibitor physostigmine. The diagnosis of central anticholinergic syndrome is often made when symptoms resolve promptly after the administration of physostigmine. We present a case of a central anticholinergic syndrome diagnosed by treatment with physostigmine, in a patient who received closure of patent foramen ovale associated with stroke.

  • PDF

Mitral Valve Replacement with a Pulmonic Autograft (자가 폐동맥 판막을 이용한 승모판막 치환술- 1례 보고 -)

  • 이재원;김건일;정성호;최현정;송명근
    • Journal of Chest Surgery
    • /
    • v.34 no.4
    • /
    • pp.361-364
    • /
    • 2001
  • 자가 폐동맥 판막을 이용한 대동맥 판막 치환술을 항응고제 복용이 필요없고 내구성이 어느정도 입증되어 늘어나고 있으나, 자가 폐동맥 판막을 이용한 승모판막 치환술은 국내에 보고된 예가 없다. 53세 여자 환자로 류마티스성 승모판막 협차가 및 폐쇄부전, 삼첨판막 폐쇄부전, 만성 심방 세동, 그리고 자회전 관상동맥의 폐색등으로 진단받은 환자에서 자가 폐동맥 판막을 이용한 승모판막 치환술 및 maze 술식, 삼천판막 성형술, 관상동맥 우회수술을 시해하였다. 수술후 특별한 문제없이 회복하였으며 술후 시행한 심초음파 검사상 자가 폐동맥 판막의 이상 소견없이 잘 기능하고 있으며 항응고제 복용없이 잘 지내고 있다.

  • PDF

Significance of p53 as a Prognostic Factor in Non-Small Cell Lung Carcinoma (비소세포 폐암종에 있어서 p53의 예후 인자로서의 의의)

  • 이상호;한정호;김관민;김진국;심영목;장인석
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.672-683
    • /
    • 2004
  • Background: The treatment results of the advanced lung carcinoma is not satisfactory with the present therapeutic modalities: surgical resection, anti-cancer chemotherapy, and radiotherapy or combination therapy. To predict the prognosis of the non-small-cell lung carcinoma, TNM classification has been was as the basic categorization; however, it has been not satisfactory. It is necessary to consider the causes and the prognosis of the lung carcinoma from another points of view rather the conventional methods. We intended to find out the relationship between the major apoptotic factor, p53 gene and the prognosis of the patient with lung carcinoma. Material and Method: Three hundreds and fifty-nine patients with lung carcinoma who underwent surgery were analysed. We observed p53 protein accumulated in the cellular nuclei. The p53 protein was detected by immuno-histo-chemical method. We collected information of the patient retrospectively. Result: p53 protein densities were observed in 40% in average as a whole. The protein density was 44 percent in man, 25 percent in woman, 49 percent in the squamous cell carcinoma, and 38 percent in the adenocarcinoma. There were significant correlations between the p53 protein density and the mortality in the squamous cell carcinoma (p=0.025), follow-up duration in TNM stage I group (p=0.010), and follow-up duration in the lobectomy patient group (p=0.043), and tumor cell differentiation (p=0.009). p53 protein densities were significantly different between the lobectomy and the pneumonectomy group (p=0.044). Conclusion: The authors found that p53 protein had some correlations with the prognosis of the lung cancer partially in some factors. We suggest the p53 protein density could be used as a marker of prognosis in the non-small-cell lung carcinoma.

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.