Clinical Analysis of Reoperation for Prosthetic Valve Replacement Report of 12 cases

인공판막 치환수술 재수술에 대한 임상적 고찰 -12예보고-

  • 장진우 (마산 삼성 병원 흉부외과) ;
  • 이연재 (마산 삼성 병원 흉부외과)
  • Published : 1997.04.01

Abstract

Between May 1986 and May 1996, 269 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 70 cases and mechanical valve was replaced in 232. Of this 12 patients performed reoperations for replacement, and the mean interval between primary valve operation and reoperation was 87.6 months for mitral valve and )7.7 months for aortic valve. There were 10 women and 2 me , agcd from 22 to 68 years(mean 45). A bioprosthetic valve was implanted in 8 cases and a mechanical valve was implanted in 4 cases for initial operation. llidications for reoperation were structural deterioration in 5 cases(42%), valve thrombus in 5 cases(42%) and endocarditis in 2 cases(17%). Operations performed included 3 aortic valve replacements(25%), 9 mitral valve replacements(75%). Wc used mechanical valve in llcases(92%) and tissue valve in 1 case(8%) for reoperation. There were 2 early operative deaths because of valve detachment and of acute respiratory failure. Among ten survivor's, there were no late deaths with follow up of 35.8 months.

1986년 5월부터 1996년 5원까지 총 269명(조직판막70례, 금속판막 232례)의 판막 치환술 환자중 판막의 재치환술이 필요했던 12례를 분석 하였다. 승모판 재치환술이 9례, 대동맥 판막 치환이 3례로 연령범 위는 16세에서 68세까지로 50대 이후가 가장 많았다. 초인공판막치환후 재 수술이 필요했던 숭모판막의 경우 평균 87.6개월, 대동맥판막의 경우 36.7개월로서, 대부분의 경우 운동시 호흡곤란이 주증상이었으며 원인으로서는 판막자체의 구조적 실패 5례, 심내막염 2례였으며 재치환술에 사용된 판막은 기계판막 11례, 조직판막 1례로 수술후 사망률은 17% (2/12)였고 술후 심내막염 및 폐렴에 의한 호흡부전으로 사망하였다.

Keywords

References

  1. Bull. Georgetown University Med Center v.6 The Surgical Correction of aortic regurgitation: Preliminary report Hufnagel CA;Harvey WP
  2. 대흉외지 v.20 이중조직판막의 장기임상성적 김종환
  3. 대흉외지 v.17 lonescu판막의 장기임상성적 김종환
  4. 대흉외지 v.19 이종심조직판막기능부전에 대한 외과적 요법 이재원;서경필
  5. J. Thorac Cardiovasc Surg v.78 Long-term evaluation of the porcine xenograft bioprosthesis Oyer PE;Stinson EB;Reitz BA(et al.)
  6. Ann Thorac Cardiovasc Surg v.34 Porcine Cardiac xenograft valves, analysis of survival, valve failure, and explanation Craver JM;Jones EL;Mickeown P(et al.)
  7. J Thorac Cardiovasc Surg v.88 Performance charactristies of the Starr-Edwards Model 1260 aortic valve prosthesis beyond the years Miller DC;Oyer PE;Mitchell RS(et al.)
  8. Ann Thorac Surg v.50 Reoperations on heart valve prostheses: An analysis of operative risks and late results Pansini S;Ottino G;Forsennati PG(et al.)
  9. Glen's Thoracic and cardiovascular surgery(5th ed.) Selection and complications of cardiac valvular prostheses Whittlesey D;Geha AS;BaueAE(eds.)
  10. Ann Thorac Surg v.37 Performance of glutaraldehyde preserved porcine bioprosthesis as a mitral valve substitute in a young population group Antunes MJ;Santos LP
  11. J Thorac Cardiovasc Surg v.93 Biological versus mechanical valves: Analysis of 1,116 valves insetted in 1,012 adult patients with a 4,818 patient year and a 5,327 valve year follow-up Hammond GL;Geha AS;Kopf GS(et al.)
  12. 대흉회지 v.24 인공판막치환수술후 재수술 유영선;권영무;최세영;이광숙
  13. J Thorac Cardiovasc Surg v.90 Results of reoperations for primary tissue failure of porcine bioprostheses Bortolotti U(et al.)
  14. J Thorac Cardiovasc Surg v.74 Replacement of prosthetic heart valves. A fifteen-year experience Sandza JG Jr;Clark RE;Ferguson TB;Connors JP;Weldon CS
  15. Arch Surg v.114 Aortic and 11mitral prosthetic valve reoperations. Early and late results Rossiter SJ;Miller DC;Stinson EB;Oyer PE;Reitz BA;Shumway NE
  16. Ann Intern Med v.86 Prosthetic valve endocarditis Wilson WR;Jaumin PM;Danielson GK(et al.)
  17. J Thorac Cardiovasc Surg v.82 Hospital mortality re-re-placement of the aortic valve Incremental risk factors Wideman FE;Blackstone EH;Kirklin JW;Karp RB;Kouchoukos NT;Pacifico AD
  18. Cardiovasc DIS(Bull Tex Heart Inst) v.5 Comparison of two suture techniques and materials: relationship to perivalvular leaks after cardiac valve replacement Bedderman C;Borst HG
  19. Am J Cardiol v.59 Isolated replacement of a prosthesis or a bioprosthesis in the mitral valve position Antunes MJ;Magalhaes MP
  20. Am J Cardiol v.59 Isolated replacement of a prosthesis on a bioprosthesis in the aortic valve position Antunes MJ
  21. J Thorac Cardiovasc Surg v.94 Comparative analysis of mechanical and bioprosthetic valves after aortic valve replacement Borkon AM;Soule LM;Baughman KL(et al.)