• Title/Summary/Keyword: 단층선

Search Result 454, Processing Time 0.025 seconds

A Paleoseismological Study of the Yangsan Fault-Analysis of Deformed Topography and Trench Survey (양산단층대의 고지진학적 연구 -변위지형 분석 및 트렌치 조사-)

  • Gyeong, Jae Bok;Lee, Gi Hwa
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.155-168
    • /
    • 1999
  • The paleoseismological importance of the Yangsan fault zone was examined by historical earthquake data, aerial photograph, and trench survey of the area. Occurrences of great earthquakes during the historical time indicate that the Yangsan and/or Ulsan fault have been active during the late Quaternary and generated historical events. Geomorphological evidences of the recent fault activity are clearly shown both in the northern segment (Yugye-ri, Tosung-ri and Naengsu-ri areas) and in the southern segment (Eonyang to Tongdosa areas) of the Yangsan fault. The main Yangsan fault is characterized by fault gouges and NNE-SSW lineaments. The reverse faulting in the Yugye-ri area generated about three-mater displacement of the lower terrace deposits. On the other hand, a major strike-slip movement with a minor component of 5-12 m vertical displacement was identified by the offset of the higher terrace surface in the Eonyang area.

  • PDF

Electric and Electromagnetic Surveys of the Hongseong Fault Zone (홍성 단층대에서의 전기, 전자 탐사 연구)

  • Kwon, Byung-Doo;Lee, Heui-Soon;Park, Gye-Soon;Oh, Seok-Hoon;Lee, Choon-Ki
    • Journal of the Korean earth science society
    • /
    • v.24 no.4
    • /
    • pp.361-368
    • /
    • 2003
  • We have investigated the electric resistivity structure of the fault zone located in the Hongseong area where a big earthquake with M 5.0 occurred in 1978. Usually, Electric and Electromagnetic methods are broadly operated in the field of engineering works since these methods are effective to understand the distribution of geological weak zones - fault or fracture zones. We have conducted the dipole-dipole array resistivity method and MT(magnetotelluric) method and interpreted the resistivity distribution of the fault zone with the aid of various inversion methods. An MT survey was performed at 18 points along a 2.9 km survey line perpendicular to the fault line and a magnetic dipole source was used to enhance the S/N ratio in the high frequency. A Electric dipole-dipole array resistivity survey with the dipole length of 50 meters was carried out perpendicular to the fault. In view of two survey results, the fault marks the boundary between two opposite resistivity structures, especially the low resistivity zone is exhibited deeply through the prospective fault line. The result that the low resistivity zone is located at the center of the fault zone corresponds with the fact that the fault zone of the Hongseong area is active. We expect these results to provide basic information about the physical properties of fault zones in Korea.

Evaluation of Dose and Image Quality of Lens according to Baseline during Brain CT Scan (두부 전산화단층촬영 시 기준선에 따른 수정체 선량과 화질 평가)

  • Kim, Kyu-Hyung;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.699-704
    • /
    • 2019
  • It is important to minimize the exposure dose during an examination and obtain good quality images at the same time. This study compared the beam harding effect according to the baseline superior orbito meatal line(SOML), orbito meatal line(OML), inferior orbito metal line(OML) and measured the exposure dose of the lens, especially in brain CT examinations, which generally apply to head diease patients. The beam harding effect assessment of each image along the baseline was performed quantitatively using the Image J program, and the exposure dose of the lens was detected by OSLDs and compared. As a result, As a result, when the SOML was used as the reference line, the dose of the lens was decreased by 85.08% at 80 kV and by 79.7% at 80 kV, compared to when IOML was used as the baseline. If the gantry angle at brain CT was parallel scan to SOML, there were no significant differences in the exposure to the lens and between the OML and IOML. Therefore, this study has shown that it is efficient to have a parallel scan on SOML as a protocol during Brain CT examinations.

X-Ray Tomography Based Simulation Feasibility Analysis of Nuclear Fuel Pellets (핵연료 펠릿의 X-선 단층촬영 기반 시뮬레이션 타당성 해석)

  • Kim, Jae-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.324-329
    • /
    • 2010
  • Fuel rods using in nuclear power plants consist of uranium dioxide pellets enclosed in zirconium alloy(zircaloy) tubes. It is vitally important for the pellet surface to remain free from pits, cracks and chipping defects after it is loaded into the tubes to prevent local hot spots during reactor operation. This paper investigates the feasibility study for detecting surface flaws of pellets contained within nuclear fuel rod through X-ray tomography simulation. Reconstructed images used by parallel and fan-beam filtered back projection method were presented and confirmed the accessibility between simulation data and MPS(missing pellet surface) image data.

Fabrication of an On System based on an Optical Delay line with Cylindrical PZT (실린더형 압전소자 광지연선을 이용한 광 간섭형 단층촬영(OCT) 시스템 제작)

  • Park, Sung-Jin;Kim, Young-Kwan;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.159-164
    • /
    • 2006
  • We demonstrate a compact optical coherence tomography(OCT) system based on the optical fiber delay line controlled by a cylindrical piezo-electric transducer(PZT). An 18-m length of single mode fiber is wrapped under constant tension around a PZT. Approximately 134 windings are used. Wraps of the long length of fiber allow the small expansion of the PZT to be magnified to an optical path length delay of 0.78 m. The OCT system shows characteristics for 2-dimensional imaging, exhibiting 96.9dB of signal-to-noise ratio(SNR), $18.6{\pm}0.5\;{\mu}m$ of axial resolution, and $5\;{\mu}m$ of lateral resolution with samples.

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

A Case Study on Design of Slope Failure in Expressway (고속도로 붕괴 절토 비탈면의 설계사례)

  • Yu, Byeong-Ok;Jang, Hyeon-Ik;Sim, Jae-Won;Han, Won-Jun;Na, Gwang-Hui
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.713-727
    • /
    • 2009
  • 절토비탈면의 붕괴는 주로 지질구조 적으로 취약한 구간에서 강우, 지진, 발파진동, 굴착 등의 외적인 요인이 작용하였을 때 비탈면의 붕괴가 수반되는 경우가 많으며 내적인 요인으로 작용하는 지질구조는 구조선의 종류에 따라 붕괴규모나 붕괴양상에서 상당한 차이를 보이는 특성을 보인다. 특히, 비탈면 붕괴는 단층이나 점토가 충전된 구조선에서 문제가 많이 발생되고 방향성이 뚜렷한 엽리 및 절리에서 붕괴가 빈번한 실정이다. 단층은 일반적으로 모든 암종에서 나타나는 지질구조이나 특히, 변성암중 편마암에서 붕괴빈도가 빈번하게 발생되고 점토층이 수반되는 경우에 심하다. 본 논문은 공사당시 비교적 규모가 크게 붕괴가 발생된 붕적층 절토 비탈면과 단층파쇄대 및 암질불량의 비탈면의 붕괴사례의 안정검토 사례를 소개하고자 한다.

  • PDF

Acquisition of High Resolution Images and its Application using Synchrotron Radiation Imaging System (방사광 X-선을 이용한 고해상도 영상획득과 응용)

  • 홍순일;김희중;정해조;홍진오;정하규;김동욱;제정호;김보라;유형식
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.51-58
    • /
    • 2001
  • Synchrotron radiation (SR) has several advantages over convetional x-rays, including its phase, collimation, and high flux. A synchrotron radiation beamline 5C1 at Pohang Light Source (PLS) was recently built for imaging applications. We have shown that a SR imaging system is useful in imaging microscopic structures. SR with broad-band energy spectrum were adjusted to an object by Si wafers and their energy were approximately ranging from 6 keV to 30 keV. SR were passed through an object and finally transformed into visible lights by CdWO$_4$ scintillator screen. The visible lights which were reflected at an angle of 90 degrees by gold plated mirror were detected by a CCD camera and the image data were acquired using image acquisition system. A high-resolution phantom, capacitor, adult tooth, child tooth, cancerous breast tissue, and mouse lumbar vertebra were imaged with SR imaging system. The Objects were rotated within the field of view of the CCD detector, and their projection image data were obtained at 250 steps over 180 degrees rotation. Image reconstructions were carried out in a PC by using IDLTM(Research systems, Inc., US) program. The spatial resolution of the images acquired by the SR imaging system was measured with a high-resolution chart manufactured for several micrometer resolution. The specimens were also imaged with conventional x-ray radiography system to compare the image quality of radiography obtained with the SR imaging system. The results showed more structural details and high contrast images with SR imaging system than conventional x-ray radiography system. The SR imaging system may have a potential for imaging in biological researches, material applications, and clinical radiography.

  • PDF

Illite Polytypes: The Characteristics and the Application to the Fault Age Determination (일라이트 폴리타입: 그 특성과 단층 활동연대 결정에의 활용)

  • Song, Yun-Goo
    • Economic and Environmental Geology
    • /
    • v.45 no.2
    • /
    • pp.181-188
    • /
    • 2012
  • The 1M and $2M_1$ stacking sequences are the most frequently encountered in the illite species among the possible 6 polytypes. The $1M_d$, derived from the 1M polytype which exhibits a variable degree of disorder in the stacking sequence, is also observed in illite samples. In this paper, the author introduces and reviews the theoretical background of the quantitative analysis method of illite polytypes, and considers the possibility to determine the fault age and its reactivation age using K/Ar age-dating based on the quantification of illite polytypes in the fault system. For the increase of the accuracy and precision of the illite age analysis method, the occurrence, identification, and mineralogical characterization of illite polytypes should be defined in detail. The broadening effect of (hkl) reflections, due to disordering of 1M polytype and the presence of I/S minerals with expandability, are also considered as the main parameters controlling the quantification of illite polytypes using the WILDFIRE(C)simulation.