• Title/Summary/Keyword: 단열설계

Search Result 225, Processing Time 0.03 seconds

A Study on the Effective Adjustment of Building Insulation Performance and the Application of the Night Purge Ventilation System for Low Energy Building Design (저에너지건축물 설계를 위한 건축물 단열성능의 효과적 조정과 야간외기 도입에 따른 에너지 시뮬레이션 연구)

  • Yun, Hyun-Su;Lee, Tae-Kyu;Kim, Jeong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.625-632
    • /
    • 2018
  • This study was done to reduce total energy demand based on resource shortage problems and to provide improvement points for more efficient adjustment of the high insulation standards for saving energy in Korea. The demand sensitivity was fully considered by varying the slope of each building. The energy performance of the building was maximized by the introduction of outdoor air at night. A final low-energy building model was developed with the two measures combined, and the short-term operation of the night-fuzzy ventilation system was simulated. The result showed a reduction of about 6 to 7 percent compared to the base model. The results could have many implications in terms of the need to conduct demand sensitivity analyses in architectural design.

The Optimum Design Conditions of Stirling Engines Using The Ideal Adiabatic Model (이상적인 단열모델에 의한 스터링기관의 최적설계조건)

  • 유호선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.656-663
    • /
    • 1990
  • To investigate the optimum design conditions of Stirling Engines at the preliminary design stage, comparative study between adoabatoc analysis based on an approximate analytical solution to the Ideal Adiabatic Model and the existing isothermal analysis has been carried out. The optimum phase angle obtained from adiabatic analysis to achieve the maximum work with given combination of design parameters is greater than that from isothermal analysis, while the optimum swept volume ratio is smaller. Effect of variation in the temperature ratio on the work parameter is proved to be stronger in adiabatic analysis. On the contrary, the work parameter by adiabatic analysis is less sensitive to a change in the dead volume ratio. Especially in adiabatic analysis there exists the optimum dead volume ratio maximizing the work parameter, which may provide a lower limit of it. Considering that the adiabatic model is more reasonable, signifiant differences between two methods lead to the conclusion that adiabatic analysis is preferable to isothermal one for the preliminary design of Stirling Engines.

A Study of an 8-b${\times}$8-b Adiabatic Pipelined Multiplier with Simplified Supply Clock Generator (단열회로를 이용한 8-b${\times}$8-b 파이프라인 승산기와 개선된 전원클럭 발생기의 연구)

  • Moon, Yong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.4
    • /
    • pp.285-291
    • /
    • 2001
  • An 8-b$\times$8-b adiabatic pipelined multiplier is designed. Simplified four phase clock generator is also designed to provide supply clocks for adiabatic circuits. All the clock line charge on the capacitive interconnections is recovered to save energy. Adiabatic circuits are designed based on ECRL(efficient charge recovery logic) and are integrated using 0.6${\mu}{\textrm}{m}$ CMOS technology. The efficiency of proposed supply clock generator is better than the previous one by 4~11%. Simulation results show that the power consumption of adiabatic pipelined multiplier is reduced by a factor of 2.6~3.5 compared to a conventional pipelined CMOS multiplier.

  • PDF

Performance Improvement of Stratified Thermal Storage Tank Using Heat Insulator (단열층 사용을 통한 성층 축열조 성능개선)

  • Lim, Se Hwa;Lee, Tae Gyu;Shin, Seungwon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.65-72
    • /
    • 2014
  • The purpose of this study is to design a heat insulator for reducing available energy loss in stratified thermal storage tank. Heat insulator is operated by buoyancy effect from density difference between hot and cold water without extra equipment. Analysis model using the Matlab Simulink was developed to estimate the internal temperature distribution in thermal storage tank and also used to select proper material and thickness of the heat insulator. Operational feasibility was confirmed through reduced scale experiment. As a result, heat insulator can effectively delay the formation of thermal boundary layer between hot and cold water. In reduced scale experiment, heat insulator can preserve additional 1540J of available energy. When applied to the real thermal storage tank, increase of 6% thermal storage efficiency can be expected.

Insulation Performance Evaluation through Insulation Test and Transient Heat Transfer Analysis of Cryogenic Common Bulkhead Propellant Tanks (극저온 공통격벽 추진제 탱크의 단열 시험과 과도 열전달 해석을 통한 단열 성능 평가)

  • Yeji Kim;Gyeong-Han Lee;Sang Min Choi;Sang-Woo Kim;Soo-Yong Lee
    • Journal of Aerospace System Engineering
    • /
    • v.18 no.4
    • /
    • pp.109-116
    • /
    • 2024
  • The validity of the analysis results was confirmed based on the insulation test results, and the vaporization mass generated in the common bulkhead was calculated to evaluate the common bulkhead propellant tank's insulation performance. The analysis results were validated by comparing the transient heat transfer analysis with the insulation test results. A transient heat transfer analysis was subsequently conducted on the common bulkhead propellant tank, considering the internal heat conduction in the propellant tank and natural convection heat transfer due to the outside air. This analysis extracted the heat flux generated in the common bulkhead and quantified the vaporization mass, a key indicator of insulation performance. Consequently, the vaporization mass was calculated at 0.09 kg, below the insulation design standard of 0.12 kg for the common bulkhead propellant tank, confirming it meets the insulation performance standard.

A Study on the Application of Thermal Insulation Composite Frame for Welding in Enclosed Space (밀폐 공간에서 용접작업을 위한 단열 복합재 프레임의 설계 적용 연구)

  • Lee, Jae-Youl;Jeong, Kwang-Woo;Hong, Sung-Ho;Shin, Kwang-Bok
    • Composites Research
    • /
    • v.31 no.5
    • /
    • pp.227-237
    • /
    • 2018
  • In this paper, the design application for the lightweight and insulation of the manipulator of the mobile welding robot for the closed/narrow space is presented. A variety of robotic platforms have been developed for weld-worker using a welding robot outside a workpiece for welding work in a complex and narrow space such as a ship or an offshore plant. Normally, The development process of robots consists of machine development, electronic device development, control algorithm development and integration verification considering application environment and requirements. In order to develop the robustness of the welding robot, the lightweight design of the robot manipulator considering the environmental conditions was performed in the basic design of the robot platform. Also, The results of the robot selection and validation, analysis and testing for the insulation performance and cooling performance and the results of the research are shown.

A Study on Fabrication and Characterization of Inorganic Insulation Material by Hydrothermal Synthesis Method (1) (수열합성법을 이용한 무기계 단열소재 제조방법 및 특성에 관한 연구 (1))

  • Seo, Sung-Kwan;Chu, Yong-Sik;Lee, Jong-Kyu;Song, Hun;Park, Jae-Wan
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.3
    • /
    • pp.219-224
    • /
    • 2013
  • In this study, the inorganic insulating material was fabricated with quartzite, ordinary portland cement(OPC), lime and anhydrous gypsum. After characteristic analysis of slurry, the optimum mixing ratio was derived with different $CaO/SiO_2$ mole ratio. Based on derived mixing ratio, the inorganic insulating material was fabricated at different water content and hydrothermal synthesis conditions. Specific gravity was $0.26g/cm^3$, compressive strength was 0.4 MPa, and thermal conductivity was 0.064 W/mK. This properties were enhanced performance of conventional ALC (Autoclaved Lightweight Concrete). And it can replace organic insulation with harmless inorganic insulation through continues research and development.

An Experimental Study on a Performance Evaluation of Internal Insulation of Buildings Over 20 Years Old (20년 이상 경과된 노후건축물의 단열재 성능평가에 관한 실험적 연구)

  • Kim, Hyun-Jin;Choi, Se-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.539-547
    • /
    • 2019
  • Recently, the international community signed a climate change agreement to prevent global warming. Yet currently, the fossil fuels have been widely used in to supply building energy for cooling and heating. The Green Building certification (G-SEED), an energy efficiency rating for new or existing buildings requires that buildings meet certain conditions. Insulation is used as a building material to reduce the energy supply to buildings and to improve the thermal insulation, and it accounts for more than 90% of the total heat resistance provided by the building surface components that meet the energy-saving design standards of new buildings. In this investigation, a performance evaluation study was conducted through an experimental study by directly extracting the foam polystyrene insulation on-site during the remodeling of a building that was in the range of 22~38 years old. Through tests, it was found that the thermal conductivity of the extrusion method insulation (XPS) was reduced by 48% and the compressive strength of XPS decreased by 36% compared to KS M 3808, which is the initial quality standard. For bead method insulation (EPS) with a thickness of 50mm, the thermal conductivity, the compressive strength, and flexural failure load were similar to the initial quality standard. Therefore, in the calculation of the primary energy requirement per unit area per year, the performance of bead method insulation can be estimated simply by considering the thickness of the insulation, while a correction factor that considers its performance deterioration should be applied when extrusion method insulation is used.

A study on the design of tunnel lining insulation based on measurement of temperature in tunnel (터널 온도계측을 통한 라이닝 단열 설계에 관한 연구)

  • Kim, Dea-Young;Lee, Hong-Sung;Sim, Bo-Kyoung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.13 no.4
    • /
    • pp.319-345
    • /
    • 2011
  • In case of tunnels in cold regions, a freeze of groundwater around tunnel may act as a barrier of tunnel drainage in winter, or may cause the inner extrusion of lining. In spite of that, a design of insulation for preventing the frost damage of tunnel lining has not been introduced in Korea, while foreign countries such as Norway and so on have a standard on insulation. In this study, a few freezing cases of road tunnels have been reviewed, and the results show that the freezing protection is necessary. In order to characterize the thermal distribution in the tunnel, following measurements have been performed at Hwa-ak tunnel; the temperature distribution by longitudinal lengths, the internal temperature of lining and the temperature distribution of the ground under pavement. From these measurements, the characteristics of the tunnel's internal temperature distribution due to temperature change in the air has been analyzed. Based on the measurement results on the temperature distribution at Hwa-ak tunnel, thermal flow tests on the rock specimen with and without insulation have been performed in the artificial climate chamber to investigate the performance of the insulation. Also, a number of 3D numerical analyses have been performed to propose appropriate insulation and insulation thicknesses for different conditions, which could prevent the frost damage of tunnel lining. As a result of the numerical analysis, air freezing index of 291$^{\circ}C{\cdot}$ Hr has been suggested as the threshold value for freezing criteria of groundwater behind the tunnel lining.

Shear Performance Evaluation of Composite Thermal Insulation with Quasi-Non-Combustible according to Adhesive Type (부착 유형에 따른 준불연 복합단열판 전단성능평가)

  • Choi, Ki-Sun;Oh, Keunyeong;Park, Keum-Sung;Ha, Soo-Kyung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.5
    • /
    • pp.507-518
    • /
    • 2022
  • The purpose of this research is to obtain experimental data for developing a structural design of an external insulation system by evaluating the shear performance of a composite insulation system according to the adhesive type. The shear performance of the composite insulation system was experimentally evaluated by considering a simultaneous placement method, full and spot/edge coverage using adhesive mortar. As a result of the test, the shear strength of simultaneous placement and full coverage method was almost similar, the spot/edge coverage method was about 80% of them. Also, the simultaneous placement method is considered to be constructively advantageous when applied as an external insulation system to a high-rise building compared to using an adhesive mortar.