• Title/Summary/Keyword: 다중 접지

Search Result 76, Processing Time 0.041 seconds

Improvement of Reception Noise During Formation Flight of Aircraft (항공기 편대 비행 중 수신 잡음 개선 연구)

  • Kwon, Jung-Hyuk;Seo, Hong-Eun;Lee, Wang-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.6
    • /
    • pp.497-504
    • /
    • 2021
  • This paper presents improvement of the reception noise suppression method during formation flights of aircraft. Since aircraft communication equipment is very important for flight mission and safety to perform the functions of internal/external communications, it is required to implement noise-free, clean communication quality, and transmitting/receiving functions. Therefore, the FTA (Fault Tree Analysis) analysis and failure search were performed on the reception noise, and the internal noise of the intercom that affected the reception noise and the none-transmition phenomenon was identified. We changed the multiple grounds of the intercom to a single ground and applied an improved method of filtering the DC Offset voltage. As a result, the voice quality of the communication system of the aircraft was improved through the reduction of the reception noise during formation flights, and it was verified by ground and flight tests.

Multi-Band Rejection Slot-Shaped DGS and Its Equivalent Circuit Model (다중 대역 슬롯형 DGS와 등가 회로 모델)

  • Woo, Duk-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.5
    • /
    • pp.537-543
    • /
    • 2010
  • This paper presents a slot-shaped defected ground structure(DGS) which has multi-band rejection property. The proposed structure, in which the spiral slot-shaped defects with different size are aligned in the transverse direction to the guiding direction of the coplanar waveguide(CPW), provides multiple resonance frequencies. Compared with the simulated results, the band rejection characteristic is in good agreement with the measurement. Also, an equivalent circuit model of the proposed structure is presented, where the DGS on the ground plane is modeled as LC-resonators. This resonators are inductively coupled to the signal line through mutual inductance. From the equivalent circuit model, multi-band rejection property was derived.

Development of a new Ground Resistance Tester for Power Electric Poles (다중접지계통의 접지저항 및 누설전류 자동측정장치 개발)

  • Shon, Su-Goog;Jeong, Yeong-Ho;Choi, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.675-678
    • /
    • 2000
  • This paper has proposed a new digital ground resistance tester for electrical systems. It features automatic operation with an injected current source. Without climbing electric power poles a worker can measure safely and quickly a ground resistance and current along the ground line.

  • PDF

Ground fault current variation of 22.9kV CD type superconducting cable system (22.9kV 중성점 다중접지계통에 CD형 초전도케이블을 적용한 경우의 지락전류변화)

  • Lee, Geun-Joon;Lee, Sang-Han;Son, Song-Ho;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.46-47
    • /
    • 2006
  • 본 논문은 CD형 초전도 케이블을 22.9kV 다중접지 배전계통에 적용한 경우 불평형 지락 고장이 초전도 케이블에 미치는 영향을 검토하고 이로 인한 중성선 전류의 변화 및 계통보호를 위한 대책을 논한다. 3상 CD형 초전도 케이블을 사용하는 경우 귀로선은 전향선과 전류가 반대이면서 거의 동일한 전류가 흐르므로 회로의 인덕턴스를 크게 줄일 수 있지만 이를 위해 회로를 단락하여 운전하는 경우 지락고장시 영상회로가 별도로 존재하지 않으면 지락전류를 저감시키는 결과를 초래하게 되어 계통보호에 영향을 주게 된다. 본 논문은 EMTDC 프로그램을 활용하여 이 현상을 XLPE 케이블 계통과 비교, 모의하는 한편, 정상적인 보호계전기 동작이 가능토록 하는 대책에 대해 논한다.

  • PDF

Study for the Grounding Resistance of the Mesh Grounding Electrode by Water Tank Model (수조모델을 이용한 메쉬접지극의 접지저항에 관한 연구)

  • Kim, Ju-Chan;Kim, Sung-Sam;Choi, Jong-Gyu;Lee, Chung-Sik;Koh, Hee-Seog
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.3
    • /
    • pp.28-35
    • /
    • 2006
  • Recently, a number of equipments related with electricity, electronics, and communication in the same building are needed to the grounding system for safety from unexpected accidents. When the faulted electric current flows into a certain grounding system, the potential rise in that system takes place and it might induce the potential rise to other grounding system. This potential interference was strongly affected by the surface potential, which was deeply related with the electrode shape. In this paper, the fundamental formula was deduced on the basis of surface potential of two grounding electrodes. Which corresponds to source of the potential interference and other grounding electrode, respectively. Therefore, the degree of potential interference in this mesh grounding electrode system was verified by the simple model simulation. In addition, in order to identify the difference between the grounding resistance in the realistic construction site and the expected value from the corresponding simulation, the experiment was performed with model on a reduced scale about the realistic grounding system. It consists of stainless steel hemisphere electrodes in a water tank. From this work, the grounding resistance in the mesh grounding electrode showed the good coincidence results between those. Consequently, it is confirmed that the grounding resistance in the mesh electrode is possible to be estimated by performing the experiment using the water tank model.

electrical shock accident prevention method and risk assesment as grounding type on the low-voltage handhole using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 지중함 접지방법에 따른 전격위험성 평가와 감전사고 예방대책)

  • Han, Woon-Ki;Kim, Jong-Min;Bang, Sun-Bae;Jung, Jin-Soo;Jung, Jong-Woo;Lee, Jun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2204-2205
    • /
    • 2008
  • 2005년도에 저압 지중함에서 감전사고가 발생한 후 감전예방을 위한 다양한 개선대책이 현장에 적용되었다. 사고발생 직후에는 지중전선의 접속부에 테이핑처리에 의한 보완조치가 적용되었으며, 그 이후 전선 접속 부를 방수형접속재로 교체하는 작업이 시행되었으며 전선 접속부 위를 감전방지용 절연고무판으로 덮거나 차량의 통행이 없는 일부 지중함의 뚜껑을 절연재질인 고강도플라스틱(FRP)으로 교체하거나 그 이외에 다중접지된 중성선과 지중함의 틀을 본딩하는 개선대책 등이 현장에 적용되었다. 이러한 다양한 개선대책은 지중함에서의 감전사고를 예방하기 위한 것으로 그중 틀접지는 이미 적용된 지중함 내의 접지설비와 중성선이 공통접속된 상태에서 지중함과 맞닿는 틀에 접지도체를 연결하는 것이다. 계통의 중성선을 이용한(TN-C)방식의 틀접지는 효과가 있으나 뚜껑부분의 진동방지를 위하여 삽입한 고무패킹은 성능저하를 일으키므로 그에 대한 대책이 필요하였다.

  • PDF

Study on the installation for DAS(Distribution Automation System) which the Grounding Fault Detection is possible in Non-Grounding System (비접지계통에서 지락고장검출이 가능한 배전자동화시스템 구축)

  • Park, Hak-Yeol;Kim, Ju-Seong;Seol, Ieel-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1_3
    • /
    • 2009
  • 국내 내륙 전체 배전계통은 "22.9kV-Y 중성선 다중접지방식"으로 일원화하여 운영 중에 있으나 도서 섬지역은 자체 내연력 발전 설비를 갖추고 380V-Y로 발전하여 $6.6kV-{\Delta}$로 승압 후 전력을 공급하고 있다. 현재 한전은 설비용량 200kW이상 38개 도서에서 비접지 계통으로 운영 중에 있다. KEPCO와 KDN은 비접지계통($6.6kV-{\Delta}$)으로 운영중인 도서 중 전북지사 부안지점 관내 위도에 시범운영을 통해서 실선로에서 비접지 1선 지락 고장 검출여부 검증을 시행하였다. 시범운영에는 배전자동화 시스템 주장치 1식, mFRTU 12대를 개폐기와 같이 설치하였는데, mFRTU에는 독창적이고 상용화 가능한 "비접지 지락고장검출 알고리즘" 개발하여 탑재하였으며 1선 지락고장을 발생시켜 mFRTU가 고장선로와 고장지점을 정확하게 검출하는지 여부를 검증하였다. 이번에 비접지계통 실선로에서 지락고장을 완벽하게 검출한 가장 큰 의의는 국내 및 해외 최초로 비접지 지락고장검출을 성공하였다는 것입니다. 본 논문에서는 비접지로 운영중인 도서지역에 배전자동화시스템 기반으로 지락고장검출하는 기능을 상용화하여 운영중인 시스템에 대한 내용이다. 이번에 구축한 배전자동화시스템은 비접지계통에 알맞도록 개발된 자동화용 개폐기와mFRTU에 지락고장검출 알고리즘을 기능 구현하였다. 선로에 1선지락 고장발생시 mFRTU가 고장선로, 고장구간 및 고장상 등을 판단하고 상위 주장치에 전송한다. 주장치는 고장정보를 HMI 단선도에 고장지점을 표시하여 종합적으로 감시제어 할 수 있는 시스템이다.

  • PDF

Assessment of material analysis for standard type pole transformers (표준형 주상변압기의 재료에 대한 성능평가기술)

  • Soh, Jin-Joong;Shim, Dae-Sup;Lee, Ki-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.110-113
    • /
    • 2003
  • 22.9kV-y 3상 4선식 다중접지 배전계통에 사용하는 단상의 표준형 주상변압기의 규격이 2003. 03에 제정이되었다. 표준형 주상변압기는 기존의 일반형, 저손실형, tap형, tapless형, 내염형 등의 다양한 종류의 제품을 기준치와 구조를 통일하여 표준화된 규격이다. 표준형 주상변압기에 사용하는 재료의 평가는 외함, 접지단자, 압착단자, 개스킷 절연유 붓싱단자, 애자의 홉습, 및 기타시험을 실시하며, 평가시험은 한전규격 KS 및 IEEE 등의 국제 표준규격을 기본으로 평가를 하여야 한다. 본 평가기술에서는 재료시험에 대한 시험방법을 검토하고 시험에 적용하여 시험 시 문제점을 도출하고 시험방법을 정립하여 주요업체의 재료에 대한 비교평가하고자 한다.

  • PDF

Reliability Improvement way for the Electric Power Equipement in a Campus (대학구내 전력설비의 신뢰도향상 방안)

  • Park, Se-Hyun;Ku, Bon-Hui;Cha, Jun-Min
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.155_156
    • /
    • 2009
  • 대학교 및 교육시설의 전력시스템을 담당하는 변전소는 공급의 신뢰도 및 안정성이 중요하다. 그러므로 보호시스템의 확실한 동작 확보를 위한 각종계전기의 원할 한 보존 상태와 전력품질에 저해되는 각종요소에 대한 방지대책이 필요하다. 특히 중요 실험실은 무 정전 전력공급에 의한 집중관리를 필요로 하며 변전설비의 정상적인 동작확보를 위한 노력도 필요하다. 먼저 급전방식의 특성과 설비의 특징을 살펴보고 보호계전기의 확실한 동작을 위한 다중접지계통(22.9kv)방식과 비 접지계통(6.6kv)방식의 보호계전방식에 관하여 검토해 보았다. 그리고 각 요소별 고장률을 산정하고 전력품질의 저해요소와 신뢰도 향상방안에 관하여 살펴보았다. 이를 통해 전력시스템의 안전한 사용과 고품질의 전력을 공급할 수 있을 것으로 판단된다.

  • PDF

The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System (22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석)

  • Jung, Kum-Young;Choi, Sun-Kyu;Shim, Keon-Bo;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.