• Title/Summary/Keyword: 뇌영상

Search Result 901, Processing Time 0.029 seconds

Acute High-Altitude Cerebral Edema Presenting as Extensive Microbleeds along the Corpus Callosum without T2 Hyperintensity: A Case Report and Literature Review (T2 고신호강도가 동반되지 않은 뇌량의 광범위한 미세출혈의 형태로 나타난 고산병: 증례 보고 및 문헌 고찰)

  • Jin Young Son;Jee Young Kim;Sanghyuk Im
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.953-958
    • /
    • 2021
  • High-altitude cerebral edema (HACE) is a potentially fatal neurological syndrome that develops in persons traveling to a high altitude. We report the case of a 49-year-old male who had traveled to a high altitude, and lost consciousness for a few hours. Susceptibility-weighted images revealed multiple, fine black pepper like microbleeds along the corpus callosum with several microbleeds in the left frontal and parietal subcortical white matter. The T2-weighted images did not show any abnormal signal intensities along the corpus callosum. The diffusion-weighted images revealed small nodular high signal intensities in the basal ganglia. This report describes the atypical radiologic findings of HACE showing multiple microbleeds along the corpus callosum, without abnormal high-signal intensity on T2-weighted images.

Medical Image Database for Morphometric and Functional Analysis of Brain Images (뇌 영상의 형태적 및 기능적 분석을 위한 의료 영상 데이터베이스)

  • Kim, Tae-U
    • The KIPS Transactions:PartB
    • /
    • v.8B no.2
    • /
    • pp.164-172
    • /
    • 2001
  • 본 논문에서는 시각화와 공간적, 속성 혼합 쿼리를 수행할 수 있는 관계형 데이터베이스를 설계하고 구현하였다. 쿼리에 사용되는 데이터형은 슬라이스, MPR, 볼륨 렌더링으로 시각화할 수 있으며, 쿼리는 아탈라스를 이용하는 경우와 그렇지 않는 경우를모두 고려하였다. 영상 데이터는 공간충전 곡선으로 공간적으로 클러스트링한 후 무손실 압축하여 데이터베이스에 저장된다. 본 논문은 저장 데이터의 양을 줄이기 위하여 관심영역의 크기에 따라 창의 크기가 변하는 적응적 Hibert 곡선을 제안하였으며, 실험에서 Hibert 곡선의 적용한 데이터보다 약 1.15배 높은 압축율을 보였다. 또한 아틀라스에 대한 뇌종양의 공간적 쿼리 결과를 통하여 본 의료 영상 데이터베이스의 유용성을 보였다.

  • PDF

Gamma-Variate Function을 이용한 관류강조영상(Perfusion MRI) 프로그램 개발 및 평가

  • 백현만;김대원;정성택;박민석;류완석;최환준;최보영
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.128-128
    • /
    • 2002
  • 목적: Gamma-Variate Function을 이용하여 뇌 관류에 관련하는 새로운 재구성 영상 (CBV, CBF, MTT, TTP, BAT)을 산출할 수 있는 프로그램을 개발 및 평가 대상 및 방법: 뇌 관류와 관련한 정량적인 재구성 영상(CBV, CBF, MTT, TTP, BAT)을 얻기 위하여 Gamma-Variate Function을 이용한 Post-processing 프로그램을 개발하였다. 자기공명영상은 1.5T & 3.0T Magnum (Medinus Co., Ltd.)을 사용하였으면, 개발된 프로그램 평가를 위해 스핀에코 -EPI 펄스시퀀스(TR 2000 ms, TE 80 ms, FOV 260 mm, matrix 92$\times$128)를 사용하여 관류강조영상을 획득하였다.

  • PDF

A Feasibility Study on Spectrogram-based Deep Learning Approach to Resting State EEG-to-MRI Cross-Modality Transfer (휴식상태 EEG-to-MRI 크로스 모달리티 변환을 위한 스펙트로그램 기반 딥러닝 기법에 관한 예비 연구)

  • Gyu-Seok Lee;Arya Mahima;Wonsang You
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2023.05a
    • /
    • pp.13-14
    • /
    • 2023
  • 뇌의 전기적 신경활동을 측정하는 뇌전도(EEG)는 저렴하게 취득할 수 있고 높은 시간 해상도를 갖는 반면 공간적 정보를 제공하지는 않는다. 기능적 자기공명영상(fMRI)은 혈류변화를 감지하여 뇌활동을 측정하는 방식으로서 높은 공간 분해능을 갖지만 고가의 비용과 설비를 요구한다. 최근 저렴하게 취득할 수 있는 EEG 데이터로부터 딥러닝을 사용하여 fMRI 합성영상을 생성하는 기술이 제안되었지만, 저주파수 대역에서 EEG와 fMRI 간의 뇌과학적 상관관계를 반영하지는 않는다. 본 연구에서는 휴식상태에서 취득된 EEG 데이터를 스펙트로그램으로 변환한 후 저주파수 특성을 사용하여 fMRI 합성영상을 생성하는 U-net 기반의 크로스 모달리티 변환 모델의 실현가능성을 평가하였다.

Sound Design Emotion-Response on TV-CF Audio using the Brain Quotient-Test (TV광고음향의 사운드디자인 감성반응 -뇌 지수(BQT)분석기법으로-)

  • Yoo, Whoi-Jong;Moon, Nam-Mee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.45-49
    • /
    • 2008
  • 본 연구는 TV광고음향의 사운드디자인에 대한 수용자 감성반응에 관한 연구이다. 연구방법으로 영상구조에서 음향이 없는 상태와, 음악설계사운드디자인을 제시 하였을 때 수용자가 받아들이는 음향감성반응을 뇌파측정을 통한 뇌 지수(BQT) 비교 방법으로 분석하였다. 본 연구를 통하여 영상에 있어 사운드의 시청각적 감성효과가 사운드디자인설계에 의하여 달라질 수 있음을 정량적 방법으로 확인할 수 있었다.

  • PDF

Semi-automated Tractography Analysis using a Allen Mouse Brain Atlas : Comparing DTI Acquisition between NEX and SNR (알렌 마우스 브레인 아틀라스를 이용한 반자동 신경섬유지도 분석 : 여기수와 신호대잡음비간의 DTI 획득 비교)

  • Im, Sang-Jin;Baek, Hyeon-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.157-168
    • /
    • 2020
  • Advancements in segmentation methodology has made automatic segmentation of brain structures using structural images accurate and consistent. One method of automatic segmentation, which involves registering atlas information from template space to subject space, requires a high quality atlas with accurate boundaries for consistent segmentation. The Allen Mouse Brain Atlas, which has been widely accepted as a high quality reference of the mouse brain, has been used in various segmentations and can provide accurate coordinates and boundaries of mouse brain structures for tractography. Through probabilistic tractography, diffusion tensor images can be used to map comprehensive neuronal network of white matter pathways of the brain. Comparisons between neural networks of mouse and human brains showed that various clinical tests on mouse models were able to simulate disease pathology of human brains, increasing the importance of clinical mouse brain studies. However, differences between brain size of human and mouse brain has made it difficult to achieve the necessary image quality for analysis and the conditions for sufficient image quality such as a long scan time makes using live samples unrealistic. In order to secure a mouse brain image with a sufficient scan time, an Ex-vivo experiment of a mouse brain was conducted for this study. Using FSL, a tool for analyzing tensor images, we proposed a semi-automated segmentation and tractography analysis pipeline of the mouse brain and applied it to various mouse models. Also, in order to determine the useful signal-to-noise ratio of the diffusion tensor image acquired for the tractography analysis, images with various excitation numbers were compared.

Assessment of Attenuation Correction Algorithms With a $^{137}$Cs Point Source (Cs-137 점선원을 이용한 감쇠보정기법들에 대한 평가)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Park, Hae-Jung;Kwon, Yun-Youn;Son, Hye-Kyoung;Yun, Mi-Jin;Lee, Jong-Doo;Jung, Hae-Jo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.96-99
    • /
    • 2004
  • The objective of this study is to assess attenuation correction algorithms utilized in a multipurpose whole-body GSO PET scanner. Four different types of phantoms were tested using different types of attenuation correction techniques. FOV (Field of View) of 256mm was used for brain PET imaging. For compensating attenuation, transmission data of a $^{137}$Cs point source were acquired after the F-18 emission source was infused to the phantoms. Scatter correction were peformed. Reconstructed images of the phantoms were assessed. In addition, reconstructed images of a normal subject were compared and assessed by nuclear medicine physicians. As a result, decreased intensity at the central portion of the attenuation map with cylindrical phantom was noticed during use of the measured attenuation correction. On the other hand, segmentation or remapping attenuation correction provided uniform phantom image. the images reconstructed from the clinical brain data explained the attenuation of a skull, at though reconstructed images of the phantoms couldn't explain it. in conclusion, the complicated and improved attenuation correction methods were required to obtain the better accuracy of the quantitative brain PET images. Our study will be useful in improving quantitative brain PET imaging modalities with attenuation correction of $^{137}$Cs transmission source.

  • PDF

A Study of the Effect of Acoustic Noise Attenuator on Auditory Functional MRI (소음 감쇠기를 이용한 청각의 뇌기능 자기공명영상)

  • Kim, S.H.;Kim, I.S.;Lee, J.J.;Park, J.A.;Lee, Y.J.;Yeo, J.R.;Bae, S.J.;Lee, S.H.;Chang, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.134-139
    • /
    • 2005
  • Purpose : To evaluate the usefulness of acoustic noise attenuator on auditory fMRI examination. Materials and methods : The acoustic noise attenuator consists of mask, earmuff and silicon earplug. The soft polyurethane sheet and polyurethane form , which has a good soundproof characteristic were used for mask and earmuff. Auditory fMRI experiments of 500 Hz pure tone stimulation were performed in three different cases; first all of mask, earmuff and earplug, secondly earmuff and earplug only and finally without attenuator in 4 normal hearing volunteers. For data acquisition, BOLD MR imaging technique was employed at a 1.5T MR scanner equipped with high performance gradient system. The raw data were analyzed using a SPM-99 analysis software and the activation maps were obtained. Results : In case of all items of acoustic attenuator used, the results revealed that activation was focused on primary auditory area. When only earmuff and earplug were used, the results showed that the activation spread over primary auditory and secondary associative areas. Last, when no device used, only weak activation was observed on the right auditory cortex. Conclusion : It is expected that the acoustic noise attenuator, which consists of earplugs, earmuffs and mask, is a very useful device in auditory fMRI study.

  • PDF

The Study on Signal to Noise Ratio of Single-Shot Turbo Spin Echo to Reduce Image Distortion in Brain Stem Diffusion MRI (뇌줄기 확산강조 자기공명영상검사 시 뒤틀림을 줄이기 위한 SS-TSE 기법의 신호대잡음비 연구)

  • Koo, Nohyun;Lee, Hobeom;Choi, Kwanwoo;Son, Soonyong;Yoo, Beonggyu
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.241-246
    • /
    • 2016
  • The purpose of this study was to investigate the problems of low signal-to-noise ratio(SNR) of single-shot turbo spin echo(SS-TSE) by quantifying numerically decreased signal to noise ratio. Thirty five patients without brain disease underwent diffusion MRI in 3T scanner from July to October in 2015. Single shot echo planar imaging(SS-EPI) which is conventionally used in MRI was taken to compared SS-TSE in SNR of medulla oblongata. As a result, SNR of SS-TSE diffusion(b0=$314.41{\pm}42.96$, b1000=$117.33{\pm}14.04$) is than SS-EPI diffusion(b0=$514.84{\pm}48.97$, b=$208.65{\pm}25.70$) lower in b=0 image(38.9%) and b=1,000 image(43.8%). Thus, diffusion MR using SS-EPI of MS-EPI should be taken for diagnosis of disease in brain stem due to decreased SNR of diffusion using SS-TSE.