• Title/Summary/Keyword: 냉장고 소음

Search Result 72, Processing Time 0.024 seconds

Study on Noise Reduction of an Axial Fan for Refrigerator through Modification of the Blade Tip (깃 끝단 개선을 통한 냉장고용 축류홴 저소음화에 대한 연구)

  • 김창준;전완호;정용규
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.639-644
    • /
    • 2002
  • In this paper, a successful noise reduction of an axial flow fan for a refrigerator is presented. The vortex sheet generated at the blade tip of fan was suppressed by changing the shape of the tip. The structure of vortex sheet and detailed flow pattern around the fan were studied by two-dimensional LDV(Laser-Doppler Velocimetry). Effective ways to work out the result as mentioned above are to make the tip of the blade varied in thickness and to have elliptical shapes. To seek the optimal value fur the shape of new fan, several cases were examined. Through the application of the methods, the refrigerator became less noisy by 3.8 dB(A) in terms of air-borne noise produced only by the axial flow fan compared to the current one.

  • PDF

Designing to reduce noise and vibration for wine refrigerator (와인냉장고 소음 진동 저감을 위한 설계기술)

  • Kim, Tae-Hoon;Seo, Min-Young;Kang, Myoung-Ju;Kim, Jeong-Woon;Kim, Seok-Ro
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.870-874
    • /
    • 2006
  • This paper presents designing method to reduce the noise and vibration in the wine refrigerator. To improve the noise and gas pulsation of the compressor the silencer is designed. Base plate of the refrigerator is modified to reduce the vibration by the modal testing. By applying the spring grommet, we can reduce the transmission of the refrigerator of the compressor. We measure PWL and the vibration of LG wine refrigerator and a different wine cellar. As the result of the evaluation, we can rightly take pride in the worldwide recognition of LG wine refrigerator

  • PDF

The search for relations betwwen compressor noise and refrigerator noise (압축기소음과 냉장고소음의 관계 규명 (압축기 정음화에 의한 냉장고 정음화))

  • 유원희;백충국;송진환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.32-36
    • /
    • 1996
  • Noise radiated from refrigerator is mainly decided by compressor noise. If the compressor is silent then the refrigerator could be silent. But In some case this tendency is not true. Because there is uncertain relations between compressor noise and refrigerator noise. And the refrigerator noise is affected by the cycle-matching in the refrigerating system using compressor. In this research it was studied that the compressor noise which didn't affect some refrigerator models could affect other refrigerator models. The methods which could reduce the refrigerator noise was studied and ultimately the methods which could change the characteristics of compressor noise was presented.

  • PDF

Psychoacoustical Study for Sound Quality Index of Steady State Noise of Refrigerators (냉장고 정상상태 소음의 음질 인덱스 개발을 위한 심리음향학적 연구)

  • Kong, Kyung-Soo;Jung, Weui-Bong;Kim, Tae-Hoon;Shin, Dae-Sik;Ahn, Se-jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.26 no.5
    • /
    • pp.536-545
    • /
    • 2016
  • Household refrigerator radiates noise of which the pattern is dependent on the operating condition of its parts, such as compressor, flow fans, etc. Thus the refrigerator noise has a variety of frequency characteristics. Therefore, it is required to consider the noise characteristics for evaluating the noise quality and eventually developing the sound quality index of the refrigerator noise. In this study, five units of household refrigerator were selected to measure their noises that were used to generate sound sources for jury test of the study. The measured noises of five refrigerators were divided into ten kinds of sound source by considering operating condition and frequency characteristics. Additionally, the ten sources were each edited to have the same SPL of 30 dBA. Totally twenty kinds of sound sources (10-original SPL, 10-edited SPL 30 dBA) were evaluated by twenty-two subjects, and compared with their sound quality metrics. It was found that only the loudness of the metrics was meaningfully correlated with the subjective evaluation. The rests, sharpness, roughness and fluctuation strength, were not related. The conclusion of this study is that a new sophisticated index is necessary to be developed to qualitatively evaluate the household refrigerator noise.

Numerical Analysis of Fluid Flow in Freezer Duct of Refrigerator (냉장고의 냉동실내 냉기 덕트 내부의 유동해석)

  • 엄윤섭;부정숙
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.509-514
    • /
    • 2000
  • A numerical study has been performed to design duct parameters in the freezer of a domestic refrigerator. The visualization results of FDM analysis using the standard k-$\varepsilon$ model with inlet boundary conditions modelled in this paper show good agreements with the experimental ones in prediction overall flow characteristics. Dominant vortex flows are found in the left upper and right lower corners, while there exists large turbulent kinetic energy around the fan and right upper side of the fan. It, in turn, has effects on the performance and noise. It is recommended to locate the outlet far away from the fan in order to reduce the noise level.

  • PDF

Analysis of the Vibration Transmitting Characteristics of the Insulation-foam for Reducing Refrigerant-induced Noise of a Refrigerator (냉장고 냉매소음 저감을 위한 단열 발포재의 진동 전달특성 분석)

  • Han, Hyung-Suk;Kim, Min-Sung;Jeong, Weui-Bong;Seo, Min-Young;Lee, Soo-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.1
    • /
    • pp.45-50
    • /
    • 2010
  • In the refrigerator, the two-phase refrigerant-induced noise of the capillary tube in an evaporator-inlet pipe has been a great concern. The capillary tube is usually covered with insulation-foam packed in the space between inner and outer cabinets without any vibration isolation. Therefore, the refrigerant-induced vibration of the capillary tube can be easily transferred to the outer cabinet, which may increase the radiated noise. In this paper, the characteristics of transferred vibration through the insulation-foam are investigated experimentally by using the refrigerantsupplying equipment. The frequency characteristics, such as dynamic Young's modulus and loss factor, of the insulation-foam are also discussed.

Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator (냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가)

  • Heo, So-Jung;Kim, Min-Seong;Han, Hyung-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

A Study on Reduction of Refirigerant Noise in Household Refrigerator (냉장고 냉매 소음의 저감에 관한 연구)

  • Choi, Seong-Won;Hwang, Won-Gul;Sul, Seoung-Yun;Im, Hyung-Eun;Kim, Sang-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1062-1066
    • /
    • 2004
  • In this study, refrigerant noise at connection of capillary tube and evaporator is investigated. Mechanism of refrigerant noise generation is examined in side-by-side type home refrigerator with two evaporators. It is found that the refrigerant noise is generated during refrigeration room fan-off (R-fan of) for that type refrigerator. The reason is that mass flow rate gets down during R-fan of and flow pattern is changed at outlet of capillary tube. We suggest designs for reduction of refrigerant noise with horizontal double expansion device, muffler, and accumulator. To evaluate those improved designs, sound quality index is used.

  • PDF

A Study on low-Cost Sensorless Drive of Brushless DC Motor for Compressor Using Random PWM (브리시리스 직류 전동기에 랜덤 PWM을 적용한 저가형 센서리스 드라이브에 관한 연구)

  • Lee, Seung-Gun;Kim, Dae-Kyong;Yang, Seung-Hak;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.97-103
    • /
    • 2008
  • Recently, it is increased to apply sensorless drive for BLDC (Brushless DC) motor to household electrical appliances, especially in the refrigerators and air conditioners, to reduce the cost and the acoustic noise by the operation and to make their functions more comfortable for human beings. In this paper, low-cost sensorless drive for BLDE motor is implemented by random PWM (Pulse Width Modulation). The experimental results show that the electromagnetic noise was reduced and the sound quality was improved by BLDC motor sensorless random PWM Control.

A Numerical Study on Low Noise Refrigerator Fans (저소음 냉장고용 팬의 운동 해석)

  • Kim, Wook;Jeon, Wan-Ho;Jung, Yong-Gyu;Kim, Chang-Joon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.489-495
    • /
    • 2003
  • A high performance and low noise refrigerator fan has been developed in order to satisfy the customer's high quality needs, that is, luxury, big size and low noise. In this study, the characteristics of a new developed fan and a current fan was calculated and compared by using numerical simulation. Rotation of a fan makes cold air circulation inside a refrigerator. A numerical simulation of air flow shows distribution and local flow regime of a cold air flow circulation, and revealed a cause of low noise as well. Optimization of a duct shape also decreased noise level.

  • PDF