• Title/Summary/Keyword: 냉방 도일

Search Result 64, Processing Time 0.018 seconds

Characteristics of Temperature, Humidity and PPF Distribution by Covering Method and Environmental Control in Double Covering Greenhouse (이중피복 온실의 피복방법과 환경조절에 따른 온습도 및 광합성유효광량자속 분포 특성)

  • Lee, Hyun-Woo;Sim, Sang-Youn;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.1
    • /
    • pp.1-11
    • /
    • 2012
  • The objective of the present study is to provide data needed to find double covering method to be able to improve environment of temperature, humidity and PPF in tomato greenhouse. The distribution charts of temperature, humidity and PPF which were measured in environment control conditions such as thermal insulation, air heating, roof ventilation and air fog cooling in conventional and air inflated double layers greenhouses were drawn and analysed. The thermal insulation effect of the air inflated greenhouse was the same as that of conventional greenhouse because the temperature between insulation curtain and roof covering material was equal in heating season. The ventilation effect of the air inflated greenhouse was superior to the conventional greenhouse. The temperature distribution in the fog cooled greenhouse was uniform and the cooling effect was about $3.5^{\circ}C$. The condensation on the roof covering surface could be controlled by removing the moisture between insulation curtain and roof covering by using humidifier. The PPF of conventional greenhouse was more decreased than the air inflated greenhouse as time went by because the transmittance of conventional greenhouse declined by dust collected on the inside plastic film owing to rolling up and down operation for ventilation.

The Development of the Calibration Method of Building Energy Consumption by HDDm and CDDm (냉·난방도일에 따른 건물에너지 사용량 보정기법 개발)

  • Kim, Dongi;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.6
    • /
    • pp.15-26
    • /
    • 2018
  • It is difficult to check the exact building energy consumption reduction such as when green remodeling of buildings, because it is due to outdoor air temperature over the years. And in Korea although Big Data of building energy consumption is collected and managed through "The Information System of the Building Energy and Greenhouse Gases" it is underutilized because of non calibration of outdoor air temperature change. Therefore, this study aims to develope calibration method of building energy consumption by outdoor air temperature according to micro climates, and building use types. As a result of analysis, Regression equations of Building energy consumption and $HDD_m/CDD_m$ are derived and calibration method is developed by Regression coefficient.

The expectation of future cooling and heating degree day of the Seoul and Ulsan using HadCM3 (HadCM3를 이용한 서울 및 울산지역의 미래 냉.난방도일 예측)

  • Lee, Kwan-Ho;Yoo, Ho-Chun;Noh, Kyoung-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.160-165
    • /
    • 2008
  • The concern in energy reduction in the field of architecture which takes up a big weight in domestic energy consumption is gradually increasing. For this reason, a lot of research work on this matter is being carried out. Particularly, it is generally required that currently used system in a structure for energy reduction should be maximized in its efficiency. In addition, research on several energy reduction typed systems is underway. Such a research work should not only include the one in time of the present but also keep up with the trend for future-oriented research. This research paper forecasted and analyzed the trend for global warming and demand of a structure for energy in the future by applying climate scenarios to cooling degree-day and heating degree-day. Also, this research found out the decrease in heating degree-days and increase in cooling degree-days until this moment due to the progress of global warming. In addition, as for heating degree-days in the future forecasted on the basis of HadCM3, it is estimated that the range of decrease could be ever bigger starting 2040 in case of Seoul and also starting 2010 in case of Ulsan ever after respectively. In case of cooling degree-days, it is estimated that its increase range could be bigger abruptly starting 2050, and after 2080, its increase range would be much bigger.

  • PDF

A Study on the Thermal Characteristics of Jeju type Ground Heat Exchanger for Ground Source Heat Pump System applied to Jeju Island (제주도에 설치된 지열 열펌프 시스템용 제주형 지중열교환기의 열특성 연구)

  • Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.32-38
    • /
    • 2020
  • This study summarizes test methods and evaluation methods for examining the thermal characteristics of Jeju-type ground heat exchangers (GHXs) installed on Jeju Island, and analyzes the ground temperature and thermal characteristics of ground heat exchangers installed in various regions by using thermal response tests (TRT). Jeju Island is composed of volcanic rock layers, and the groundwater flow is well developed. A Jeju-type GHX can be installed up to 30 m from groundwater level after drilling a borehole. The ground heat exchanger has a structure in which several pipes are inserted into the borehole. In order to examine the characteristics of the Jeju-type GHX, tests were conducted on ground heat exchangers installed in four places on Jeju Island (Pyoseon, Jeju, Namwon, and Hallym). As a result of the analysis of the Jeju-type ground heat exchanger, the ground circulating water temperature stabilized according to the heat injection, depending on the installed location, and was formed within one to three hours. The ground heat exchanger capacity in Hallym was highest at 73.4 kW (cooling) and 82.8 kW (heating), and the Jeju-type calculation was lowest at 34.1 kW (cooling) and 23.3 kW (heating).

A Study on the Cooling Degree Days and the Number of Cooling Days in Korea (우리나라의 냉방도일과 냉방일수에 관한 연구)

  • Seol, Dong-Il;Min, Byeong-Eon
    • Journal of the Korean Institute of Navigation
    • /
    • v.15 no.4
    • /
    • pp.41-58
    • /
    • 1991
  • The cooling degree days and the number of cooling days are used as important research materials not only in the field of design for building and cooling facilities but also in the government's establishment of energy policy. The purposes of this dissertation are to clarify the distribution of the cooling degree days and the number of cooling days by using the daily mean air temperature of 95 weather stations in Korea, and to show the distribution charts of the same cooling degree days and the same number of cooling days in order to help the practical uses of the materials. In cases of the base temperatures $24^{circ}C$, $25^{circ}C$, $26^{circ}C$, and $27^{circ}C$, the cooling degree days and the number of cooling days are shown in Table 5. The distribution charts of the same cooling degree days and the same number of cooling days are shown in Fig. 6 to Fig. 8 and Fig.9 to Fig. 11 respectively. As a result of this dissertation, Jeju Island and southern inland regions(especially Jeonju, Daegu, Gwangju) have a larger value than central regions and northern regions because of the influences of the terrain effect, and western coast regions have usually a larger value than eastern coast regions at the same latitude. The largest value appears in August of the year and the second in July, and the smallest in September. And southern inland area surrounded by Imshil, Goechang, and Boeun has a much smaller value than the other areas of its vicinity.

  • PDF

Night Purge Control Strategies With Outdoor Air Temperature Conditions for Central Cooling System (중앙냉방시스템의 외기온도조건을 고려한 나이트 퍼지 제어방안에 관한 연구)

  • Hwang, Jin-Won;Ahn, Byung-Cheon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.10
    • /
    • pp.6759-6765
    • /
    • 2015
  • In this study, the effects of control strategies of night-purge control system on control characteristics and energy consumption for central cooling system in building are researched by simulation. The start time and set-point temperature for night-purge control with outdoor temperature changes and building cold storage performance are obtained. The system analysis modelling is done by using TRNSYS program package, and the control performances with suggested night-purge control method are compared with the existing control ones. As a result, the suggested night-purge control method shows maximum 16.8% and 28.6% energy saving in comparison with existing control method and conventional one without night-purge control, respectively.

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.

Temperature and Wind Control of Virtual Warmth Image Using Fuzzy Reasoning Rule (퍼지 추론 규칙을 이용한 가상의 열 영상 온도와 풍향 제어)

  • Kang, Kyoung-Min;Kim, Kwang-Baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.10a
    • /
    • pp.387-392
    • /
    • 2008
  • 본 논문에서는 에너지 절약을 위한 방법으로 여름철 냉방의 적정 온도 및 풍향을 제어하기 위한 가상의 시뮬레이션을 목적으로 열 영상과 퍼지 추론 규칙을 적용한 온도 및 풍향 제어 기법을 제안한다. 온도 제어를 위한 가상 시뮬레이션에서 열 영상을 분석하기 위해서 영상을 $300{\times}400$의 크기를 가지는 색상 분포 영상으로 변환한다. 색상 분포 영상은 Red, Magenta, Yellow, Green, Sky, Blue의 온도 값을 가지는 R, G, B 값이며 각 색상은 $ 24.0^{\circ}C$에서 $27.0^{\circ}C$의 분포의 온도 값을 가진다. 색상 분포 영상은 아래 계층부터 레벨1에서 레벨10의 높이 계층으로 분류한다. 분류한 각 계층은 고유의 색상 분포도를 가지며 색상이 가지는 온도 수치에 따라서 계층별로 온도를 구성한다. 풍향 제어를 위한 각 계층의 높이는 레벨1에서 레벨3까지는 하위층이며, 레벨 4부터 레벨 7은 중간층, 레벨 8부터 레벨 10은 상위층으로 분류한다. 각 계층의 온도와 높이 레벨 값은 온도 조절과 풍향의 우선 순위, 강도 조절, 지속 시간을 구하기 위한 파라미터이다. 실내 공간의 전체적인 온도의 균형과 풍향을 제어하는 과정으로 풍향의 방향, 지속시간을 적용하고 풍향의 강도를 구하기 위해서 색상 분포영상의 각 구간의 온도 및 높이의 특징을 적용하여 퍼지 소속 함수를 설계한 후, 소속 함수의 소속도를 구하고 퍼지 추론 규칙을 적용하여 풍향의 강도를 구한다.

  • PDF

Development and Application of the Calibration Method of Individual Building Energy Consumption (개별건물 에너지소비량 보정기법 개발 및 적용방안)

  • Kim, Dongil;Lee, Byeongho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.15-24
    • /
    • 2020
  • Building energy consumption generally depends on living patterns of residents and outdoor air temperature changes. Although outdoor air temperature changes effect on building energy consumption, there is no calibration method for the comparison before and after Green Remodeling or BEMS installation etc., Big data of building energy consumption are collected and managed by 『National Integrated Management System of Building Energy』 in Korea, and they are utilized for the development of a calibration method for individual buildings as shown as the calibration method for small-area building stocks in the previous research. This study aims to develope a calibration method using big data of building energy consumption of individual buildings and outdoor air temperature changes, and to propose application of appropriate calibration methods for individual buildings or small-area building stocks according to the calibration purpose and conditions.

A Study on Prediction of Power Consumption Rate for Heating and Cooling load of School Building in Changwon City (창원시 학교 건축물의 냉난방부하에 대한 전력 소비량 추정에 관한 연구)

  • Park, Hyo-Seok;Choi, Jeong-Min;Cho, Sung-Woo
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.11 no.2
    • /
    • pp.19-27
    • /
    • 2012
  • This study was carried out in order to establish the estimation equation for school power consumption using regression analysis based on collected power consumption for two years of weather data and schools are located in Central Changwon and Masan district in Changwon city. (1) The power consumption estimation equation for Heating and cooling is calculated using power consumption per unit volume, the difference between actual power consumption and results of estimation equations is 4.1%. (2) The power consumption estimation equation for heating load is showed 2.6% difference compared to actual power consumption in Central Changwon and is expressed 2.9% difference compared to that in Masan district. Therefore, the power consumption prediction for each school using the power consumption estimation equation is possible. (3) The power consumption estimation equation for cooling load is showed 8.0% difference compared to actual power consumption in Central Changwon and is expressed 2.9% compared to that in Masan district. As the power consumption estimation equation for cooling load is expressed difference compared to heating load, it needs to investigate influence for cooling load.