• Title/Summary/Keyword: 냉각효율

Search Result 584, Processing Time 0.025 seconds

Slim Air-Conditioner with Parallel Flow Heat Exchangers for Cooling of Telecommunication Cabinet (평행류 열교환기가 적용된 무선통신 중계기 냉각용 슬림형 공조기)

  • Cho, J.P.;Kim, N.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.87-93
    • /
    • 2009
  • Slim telecommunication cabinet cooler, equipped with parallel flow heat exchangers and operating with R-22, is developed. The performance is compared with imported one, equipped with fin-tube heat exchangers and operating with R-134a. Test results show that the newly-developed cooler increases the cooling capacity by 6% and EER by 33%. The refrigerant charge for the developed cooler is 500g compared with 1250g for the imported one. The adoption of parallel flow heat exchanger appears to have reduced the refrigerant charge. In addition, it is shown that the reduced air flow rates through parallel heat exchangers as compared with those through fin-tube heat exchangers are beneficial to the reduction of the equipment noise.

Shape optimization of angled ribs to enhance cooling efficiency (냉각효율 향상을 위한 경사진 리브의 형상최적설계)

  • Kim, Hong-Min;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.627-630
    • /
    • 2003
  • This work presents a numerical procedure to optimize the shape of three-dimensional channel with angled ribs mounted on one of the walls to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier-Stokes analysis of flow and heat transfer. SST turbulence model is used as a turbulence closure. The width-to-height ratio of the rib, rib height-to-channel height ratio, pitch-to-rib height ratio and attack angle of the rib are chosen as design variables. The objective function is defined as a linear combination of heat-transfer and friction-loss related terms with weighting factor. D-optimal experimental design method is used to determine the data points. Optimum shapes of the channel have been obtained for the weighting factors in the range from 0.0 to 1.0.

  • PDF

An Experiment on Performance Evaluation of a Direct Ambient Cooling Air Filter for Wireless Telecommunication Base Transceiver Stations (이동통신 기지국 직접대기냉각용 에어필터의 성능평가실험)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Cha, Ho-Jin;Kim, Yong-Woo;Choi, Dong-Kyu;Lee, Henry
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.436-441
    • /
    • 2006
  • In recent European telecommunication base transceiver stations(BTS) a membrane laminated air filter is reported to replace a heat exchanger in order to cool internal digital units of BTS. The concept of using the air filter is for the direct ambient cooling(DAC) of BTSs without heat loss generally found ill the heat exchanger type BTS. In the present study, a performance evaluation experiment was conducted to investigate the pressure drop characteristics with dust loading and the particle collection efficiency of the air filter for the DAC of BTS.

  • PDF

Studies of VETH Plot for Standard Design of Evaporative Cooling at Summer Glasshouse (하절기 유리온실의 증발냉각 설계기준을 위한 VETH 선도 연구)

  • Woo, Y.H.;Ahn, Y.K.;Kim, D.E.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.20 no.1
    • /
    • pp.55-66
    • /
    • 2018
  • Judicious control of high temperature is the most important task for the successful intensive-cultivation of vegetables in glasshouses during the hot summer. Estimation of cooling load and wise selection of suitable equipments and facilities based upon the environmental conditions are essential for the efficient temperature control. A series of experiments were carried out to investigate VETH(ventilation, evapotranspiration, temperature and humidity) plot was prepared for the possible practical application in designing some evaporated cooling methods for the following 9 locations; Seoul, Seosan, Taejeon, Pusan, Cheju, Kwangju, Taegu, Chonju, and Chinju.

Characteristics of Temperature Control by Hot-gas Bypass Flow Rate on Industrial Water Cooler (핫가스 바이패스 유량에 따른 산업용 냉각기의 온도제어 특성)

  • Baek, Seung-Moon;Choi, Jun-Hyuk;Byun, Jong-Yeong;Moon, Choon-Geun;Lee, Ho-Saeng;Jeong, Seok-Kwon;Yoon, Jung-In
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.8
    • /
    • pp.1129-1136
    • /
    • 2009
  • The paper presents the performance characteristics for a cooling system using EEV. The water cooler was used to reduce thermal deformation and contraction due to high speed of machine tools and the EEV was used for capacity control for water cooler. The apparatus was designed for hot-gas bypass system which a hot-gas can flows from outlet of compressor to the inlet of evaporator. This experiment is the intermediary study for precise temperature control through PID control. The results show that the evaporator pressure increased and refrigeration capacity decreased as the EEV opening step of hot-gas bypass increased. These results can be used as basic data for the design of effective water cooler.

Effects of Inlet Water Temperature and Heat Load on Fan Power of Counter-Flow Wet Cooling Tower (입구 물온도와 열부하가 냉각탑의 팬동력에 미치는 영향 분석)

  • Nguyen, Minh Phu;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.3
    • /
    • pp.267-273
    • /
    • 2013
  • In order to provide effective operating conditions for the fan in a wet cooling tower with film fill, a new program to search for the minimum fan power was developed using a model of the optimal total annual cost of the tower based on Merkel's model. In addition, a type of design map for a cooling tower was also developed. The inlet water temperature and heat load were considered as key parameters. The present program was first validated using several typical examples. The results showed that for a given heat load, a three-dimensional graph of the fan power (z-axis), mass flux of air (x-axis, minimum fan power), and inlet water temperature (y-axis, maximum of minimum fan power) showed a saddle configuration. The minimum fan power increased as the heat load increased. The conventionally known fact that the most effective cooling tower operation coincides with a high inlet water temperature and low air flow rate can be replaced by the statement that there exists an optimum mass flux of air corresponding to a minimum fan power for a given inlet water temperature, regardless of the heat load.

A Study on the Structural Integrity of the First Stage Turbine Blade Caused by Thermal Barrier Coatings and the Cooling Design of the Nozzle (터빈 노즐 및 열차폐 코팅에 따른 고압 1 단 터빈 블레이드의 구조 건전성 영향에 대한 연구)

  • Huh, Jae Sung;Kang, Young Seok;Rhee, Dong Ho
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.2
    • /
    • pp.93-99
    • /
    • 2016
  • High pressure nozzles and turbines of a gas turbine engine should be required to be operated under extreme operating conditions in order to maximize the performance. Engine manufactures have utilized nickel-base superalloys, enhanced cooling design, and thermal barrier coating techniques to overcome them and furthermore, material modeling, finite element analysis, optimization techniques, and etc. have been utilized widely for elaborate predictions. We aim to evaluate the effects on the low cycle fatigue life of the high pressure turbine blade caused by thermal barrier coatings and the cooling design of the endwall of the first stage turbine nozzle. To achieve it, the structural analysis, which utilized the results of conjugate heat transfer analysis as loading boundary conditions, was performed and then the results were the input for the assessment of low cycle fatigue life at several critical zones.

Study on Heat Transfer Characteristic in Combustor Nozzle (연소기 노즐에서의 열전달 특성 연구)

  • NamKoung, Hyuck-Joon;Kim, Hwa-Jung;Han, Poong-Gyoo;Lee, Kyoung-Hun;Kim, Young-Soo;Jeong, Hae-Seung;Lee, Sang-Youn
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.34-40
    • /
    • 2006
  • For a cooling performance research of the combustor operated in a extreme environment of a high temperature and high pressure, we accomplished a cooling performance analysis. Generally a heat transfer characteristic in cooling passage is known well experimentally and theoretically, however heat flux in the combustion chamber isn't. In this study, fluid flow combined with heat transfer and thermal structural analysis is accomplished about a combustor nozzle. We tried to analyze the cooling performance with a heat transfer characteristic of a gas and coolant side in the view point of quantity on the mass flow rate to be supplied to the cooling channel. And finally, evaluation on the thermal and structural safety of nozzle wall material was accomplished.

  • PDF

Design and Analysis of Shell Runners to Improve Cooling Efficiency in Injection Molding of Subminiature Lens (초소형 렌즈 사출성형시 냉각효율 향상을 위한 박판형 러너의 설계 및 해석)

  • Yoon, Seung Tak;Park, Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.10
    • /
    • pp.1021-1028
    • /
    • 2015
  • Subminiature lenses are currently widely used in mobile phone cameras and are usually produced by injection molding. The lens molding process has the unique feature of a runner volume that is much larger than the part volume, and this feature should be considered when determining the mold design and molding conditions. In this study, a shell-type runner was proposed as an alternative to the conventional cylindrical runner used for lens molding. An injection molding simulation was performed by applying the proposed shell runner, and the simulation results were compared with those from the cylindrical runner case. It was found that the shell runner could considerably reduce the runner cooling time with only a slight increase in the injection pressure. The effect of the runner thickness was then investigated numerically in terms of the mold filling and cooling characteristics, from which an optimal runner thickness could be determined.

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.