• Title/Summary/Keyword: 냉각시험

Search Result 581, Processing Time 0.024 seconds

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.

Comparison of Carcass and Pork Physical Characteristics by Market Weight and Gender of Berkshire (버크셔의 출하체중과 성별에 따른 도체 및 돈육의 물리적 특성 비교)

  • 이제룡;주영국;신원주;조규제;이진우;이정일;이중동;도창희
    • Food Science of Animal Resources
    • /
    • v.24 no.2
    • /
    • pp.108-114
    • /
    • 2004
  • In a trial involving 72 pigs, the effects of market weight and gender on the carcass and pork quality characteristics were investigated. A total of 72 pigs were divided into 3 groups(95-104, 105-110 or 111-120kg), market weight was assigned to 2 gender group (gilt or boar). The carcass characteristics (carcass weight, backfat thickness or grades) were determined on those carcass, longissimus muscle was removed from each left side at 5th to 13th rib and meat qualities were evaluated. The carcass weight and backfat thickness of pigs slaughtered at 111-120kg were increases than the other weights. The carcass grade of pigs slaughtered at 105-110kg had higher then at pigs slaughtered 94-104kg. Compared with boars, gilts carcass had higher in carcass weight and backfat fat. The pH$\_$u/, drip loss and cooking loss tended to similar for market weight and gender, meat of boars had higher shear force values than gilts (p<0.05). The meat color tended to similar for market weight and gender. The total myoglobin content of gilts slaughtered at 95-104kg and boars slaughtered at 111-120kg had higher than the other weight and gender. The meat of gilts had higher springiness and brittleness than boars (p<0.05). These results imply that the carcass characteristics (carcass weight and backfat thickness) could be affected by market weight and gender, meat of gilts was improved the shear force values and texture properties when compared to boars.

An Experimental Study on the Automobile Engine Room Fire Using the Extinguishing Agents (소화약제를 이용한 자동차 엔진룸 화재 실험에 관한 연구)

  • Han, Yong-Taek;Kim, Dong-Ho;Kwon, Sung-Pil
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.1-7
    • /
    • 2014
  • Several complex devices and equipments are installed in the car's engine room, including various kind of oils or other flammable materials. So re-ignition is very likely to take place in it. In addition, it is restrictive for the driver or the occupant to open the bonnet and to spray the fire extinguisher in the engine room due to the high possibility of explosion. Therefore, a fire extinguishing system, which can detect a fire and inject the fire extinguishing agent to extinguish it, and fire extinguishing agents including HFC-227ea, which can stand the high temperature within the engine room and hold the viscosity sufficient to keep it in the kind of foam, were developed and tested. And the suffocation effect and the cooling effect come from the fire extinguishing principle of the foam fire extinguishing agent and the inhibiter catalyst effect come from the one of HFC-227ea was led simultaneously, and fire extinguishing agents without the secondary damage caused by residuals after the fire extinguishment like a case of the powder fire extinguishing agent, were developed. And experiments using a vehicle collision after the discharge is complete, foreign material can be removed without extinguishing the advantage that experimental results obtained.

Assembly and Test of the In-cryostat Helium Line for KSTAR (KSTAR 저온용기 내부의 헬륨라인 설치 및 검사)

  • Bang, E.N.;Park, H.T.;Lee, Y.J.;Park, Y.M.;Choi, C.H.;Bak, J.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • In-cryostat helium lines are under installation to transfer a cryogenic helium into cold components in KSTAR device. In KSTAR, three kinds of helium should be supplied into the cold components, which are supercritical helium Into superconduction(SC) magnet system, liquid helium into current lead system, and gas helium into thermal shields. Cryogenic helium lines consist of transfer lines outside the cryostat, in-cryostat helium lines, and electrical breaks. In-cryostat helium lines should be guaranteed of leak tightness for tong time operation at high internal helium pressure of 20 bar. We wrapped the helium line with multi-layer insulator(MLI) to reduce radiation heat and insulated the surface of the high potential part with prepreg tape. The electrical break was fabricated by brazing ceramic tube with stainless steel tube. To ensure the operation reliability at operation temperature, all the electrical break have been examined by the thermal cycle test at liquid nitrogen and by the hydraulic test at 30 bar. And additional surface insulation was prepared with prepreg tape to give structural safety. At present most of the in-cryostat helium lines have been installed and the final inspection test is progressing.

A DESIGN AND DEVELOPMENT OF MULTI-PURPOSE CCD CAMERA SYSTEM WITH THERMOELECTRIC COOLING II. SOFTWARE (열전냉각방식의 범용 CCD 카메라 시스템 개발 II. 소프트웨어)

  • Oh, S.H.;Kang, Y.W.;Byun, Y.I.
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.367-378
    • /
    • 2007
  • We present a software which we developed for the multi-purpose CCD camera. This software can be used on the all 3 types of CCD - KAF-0401E ($768{\times}512$), KAF-1602E ($1536{\times}1024$), KAF-3200E ($2184{\times}1472$) made in KODAK Co.. For the efficient CCD camera control, the software is operated with two independent processes of the CCD control program and the temperature/shutter operation program. This software is designed to fully automatic operation as well as manually operation under LINUX system, and is controled by LINUX user signal procedure. We plan to use this software for all sky survey system and also night sky monitoring and sky observation. As our results, the read-out time of each CCD are about 15sec, 64sec, 134sec for KAF-0401E, KAF-1602E, KAF-3200E., because these time are limited by the data transmission speed of parallel port. For larger format CCD, the data transmission is required more high speed. we are considering this control software to one using USB port for high speed data transmission.

Veriations of Carbon Dioxide Concentration in a Strawberry Greenhouse Using Dry ice (드라이아이스를 이용한 딸기재배 온실의 이산화탄소 농도변화)

  • Paek, Yee;Kang, Suk-Won;Jang, Jae-Kyung;Kwon, Jin-Kyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.182-188
    • /
    • 2020
  • This study aimed to collect the carbon dioxide generated as a by-product from petrochemicals and liquor factories and use it in a crop breeding greenhouse. This was applied mainly to the storage of dry ice and the supply of carbon dioxide to achieve this target. Dry ice has a strong cooling effect because CO2 becomes a solid or gas at temperatures and pressures below the triple point, and the solid sublimes at -78.5℃ and atmospheric pressure. The consumption of dry ice according to temperature was 0.983kg/day, 2.358kg/day, 5.102kg/day, and 7.035kg/day when the temperature was 5℃, 10℃, 15℃, and 20℃, respectively, which corresponded to 1,102ppm, 1,481ppm, 1,677ppm, and 1,855ppm. Dry ice consumption in the test greenhouse decreased by approximately 0.9kg/h, and the CO2 concentration in the greenhouse at 9 a.m., before supplying dry ice increased to 517ppm, 1,519ppm at 10 a.m., 1,651ppm at 11 a.m., and 1,651ppm at 12 p.m., before maintaining this level of activity. Overall, this study attempted to contribute to increasing farm income by deriving the supply conditions through an expansion of the supply of carbon dioxide gas for crops.

Improvement of Cooling Efficiency in Greenhouse Fog System Using the Dehumidifier (제습기를 이용한 온실 포그냉방시스템의 효율향상)

  • Nam Sang Woon;Kim Kee Sung;Giacomelli Gene A.
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • In order to provide fundamental data on utilization of dehumidifier in greenhouses, a condensing type dehumidifier using ground water as a coolant was developed and tested dehumidification performance. The developed dehumidifier was applied to greenhouse with fog cooling system and effect of dehumidification on improvement of evaporative cooling efficiency was analyzed. Results of the dehumidifier performance test showed that dehumidification using ground water as a coolant was sufficiently possible in fog cooling greenhouse. When the set point temperature of greenhouse cooling was $32^{\circ}C$ and as temperatures of ground water rose from $15^{\circ}C\;to\;18^{\circ}C,\;21^{\circ}C\;and\;24^{\circ}C$, dehumidification rates decreased by $17.7\%,\;35.4\%\;and\;52.8\%$, respectively. As flow rates of ground water reduced to $75\%\;and\;50\%$, dehumidification rates decreased by $12.1\%\;and\;30.5\%$, respectively. Cooling efficiency of greenhouse equipped with fog system was distinctly improved by artificial dehumidification. When the ventilation rate was 0.7 air exchanges per minute, dehumidification rates of the fog cooling greenhouse caused by natural ventilation were 53.9%-74.4% and they rose up to 75.4%-95.9% by operating the dehumidifier. In case of using the ground water of $18^{\circ}C$ and flow rate of design condition, it was analyzed that whole fog spraying water can be dehumidified even if the ventilation rate is 0.36 exchanges per minute. As a utilization of dehumidifier, it is possible to improve cooling efficiency of fog system in naturally ventilated greenhouses.

Influence of temperature gradient induced by concentrated solar thermal energy on the power generation performance of a thermoelectric module (집중 태양열에 의한 온도구배가 열전발전모듈의 출력 성능에 미치는 영향)

  • Choi, Kyungwho;Ahn, Dahoon;Boo, Joon Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.777-784
    • /
    • 2017
  • Energy harvesting through a thermoelectric module normally makes use of the temperature gradient in the system's operational environment. Therefore, it is difficult to obtain the desired output power when the system is subjected to an environment in which a low temperature gradient is generated across the module, because the power generation efficiency of the thermoelectric device is not optimized. The utilization of solar energy, which is a form of renewable energy abundant in nature, has mostly been limited to photovoltaic solar cells and solar thermal energy generation. However, photovoltaic power generation is capable of utilizing only a narrow wavelength band from the sunlight and, thus, the power generation efficiency might be lowered by light scattering. In the case of solar thermal energy generation, the system usually requires large-scale facilities. In this study, a simple and small size thermoelectric power generation system with a solar concentrator was designed to create a large temperature gradient for enhanced performance. A solar tracking system was used to concentrate the solar thermal energy during the experiments and a liquid circulating chiller was installed to maintain a large temperature gradient in order to avoid heat transfer to the bottom of the thermoelectric module. Then, the setup was tested through a series of experiments and the performance of the system was analyzed for the purpose of evaluating its feasibility and validity.

A study on the development of phthalate plasticizers CRM in ABS resin (ABS 중 phthalates 가소제 CRM 개발에 대한 연구)

  • Jung, Jung-Sul;Park, Jung-Woo;Yoo, Seok;Kweon, Seong-Il;Hong, Sung-Taeg;Sun, Yle-Shik;Park, Cheon-Min;Choi, Chang-Hyoo
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.273-283
    • /
    • 2012
  • Phthalate plasticizers are regulated by RoHS, REACH and CPSC as hazardous substances. Responding to these international environmental restrictions, we developed ABS certified reference material (CRM) for determination of phthalate plasticizers such as DMP, DEP, DBP, BBP, DEHP and DnOP. The candidate material has been made with ABS resin widely used in electric and electronic products and 6 kinds of phthalate plasticizers. The making of the material involved a series of processes like extruding, cooling, pelletizing, and drying using twin screw extruder. Then it has been certified according to ISO Guide 35. Using isotope dilution-gas chromatography/mass spectrometry (ID-GC/MS), homogeneity, short-term stability, and long-term stability were evaluated. The certified values were determined by using primary reference material (PRM) of KRISS for traceability. From now on, we will provide ABS CRM to national and international companies and research institutes after certification as certified reference material and registering on COMAR (code of reference material).

Development of the Pushing Type Cutting Device to Dismantle Concrete Structure for Decommissioning of Nuclear Power Plant (원전해체 시 콘크리트 구조물 절단을 위한 밀기형 절단장치 개발)

  • Lee, Bong-Jae;Kwon, Yong-Kyu;Hong, Chang-Dong;Lee, Dong-Won;Min, Kyong-Nam
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.103-111
    • /
    • 2020
  • Pulling-type cutting devices, which use a diamond wire saw, have been used generally for cutting concrete structures. In this study, a pushing-type cutting device with a collection cover was developed by overcoming the disadvantages of pulling-type devices. In this device, dry or liquid methods can be selected to cool frictional heat. Operation and leakage tests of the dust generated during the dismantling of a concrete structure were carried out, confirming the suitable operation of the fabricated cutting device; the leakage rate was approximately 1.7%. For a conservative evaluation, the internal dose of workers was estimated in dismantling the core center part of biological shield concrete with a specific activity of 99.5 Bq·g-1. The committed effective dose per worker was 0.25 mSv. The developed cutting device contributed to reducing radioactive concrete waste and minimizing worker exposure due to its easy installation. Therefore, it can be utilized as a cutting apparatus for dismantling not only reinforced concrete structures but also radioactive biological shield concrete in nuclear power plant decommissioning efforts.