• Title/Summary/Keyword: 냉각수온도

Search Result 232, Processing Time 0.028 seconds

Performance Characteristic of Live Fishing Tank in Cooling Apparatus inshore Fishing Boat (연근해 어선용 활어조 냉각장치의 성능특성)

  • 한인근;이호생;김재돌;김흥윤;윤정민
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.1
    • /
    • pp.52-56
    • /
    • 2001
  • A fundamental study on the cooling apparatus inshore fishing boat and its operation characteristics in sea water cooling system were performed experimentally. The circumstance is giving the blow against fisherman with incoming-decreasing and the difficulty of crew's supply and demand and management. In addition, the depression of the external situation such as the plan of EEZ(Exclusive Economic Zone) proclaim is forcing them into improving their fishing condition. By this international and domestic surrounding, the development of a cooling apparatus inshore fishing boat is demanded sincerely. We investigated load characteristics as the pilot plant operation characteristics estimation which is based on the development of cooling system and optimum cooling apparatus inshore fishing boat. These results provide useful informations which are applicable to an actual design and show the possibility of application to other fields.

  • PDF

Development of a Solar Powered Water Pump by Using Low Temperature Phase Change Material ­ System Construction and Operation Analysis ­ (저온 상변화 물질 특성을 이용한 태양열 물펌프 실용화 연구개발(II) ­시스템 구성 및 작동분석)

  • 김영복;이양근;이승규;김성태;나우정;민영봉
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.69-78
    • /
    • 2003
  • In this study, the energy conversion equipment from the radiation energy to mechanical energy by using n­pentane as the operating fluid was constructed and the performance to pump the water was tested for the utilization of solar powered water pump. The equipment was designed optimally, after the theoretical analyses of the water pumping head and water quantity per cycle were done. The pentane vapour temperature in the condenser and the temperature of the outlet water from the condenser became lowered and the heat transfer rate became higher with decreasing the water inlet level to the condenser. The temperature difference between the condenser and the water tank was significant. Therefore, the distance between the water tank and condenser was recommended to be shorten and the diameter of their connecting pipe was recommended to be narrow in order to reduce the resistance of the fluid passage and improve the heat transfer rate. The amount of water pumped was 1.6­2.4 liters. Mass flow rate of the cooling water became lowered when the cooling water pipe was prolonged from the condenser to improve the heat transfer rate.

  • PDF

Numerical Study on Thermal Performances of Multi Heat Source Heating System Using Butane for Electric Vehicle (전기자동차용 부탄 연료 복합열원 히팅시스템의 열적 성능에 관한 수치적 연구)

  • Bang, You-Ma;Seo, Jae-Hyeong;Patil, Mahesh Suresh;Cho, Chong-Pyo;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.725-731
    • /
    • 2016
  • This study numerically investigates the thermal performance of a 2.0-kW butane-based combustion heating system for an electric vehicle under cold conditions. The system is used for cabin space heating and coolant-based battery thermal management. ANSYS CFX 17 software was used for parametric analysis. The mass flow rates of cold air and coolant were varied, and their effects were compared. The numerical results were validated with theoretical studies, which showed an error of 0.15%. As the outside air mass flow rates were increased to 0.005, 0.01, and 0.015 kg/s, the cabin supply air temperature decreased continuously while the coolant outlet temperature increased. When the coolant mass flow rates were increased to 0.005, 0.01 and 0.015 kg/s, the air temperature increased while the coolant outlet temperatures decreased. The optimal mass flow rates are discussed in a consideration of the requirements for high cabin heating capacity and efficient battery thermal management.

냉각수가 비등하지 않는 조건에서 용융물의 피막층 형성에 대한 2차원적 해석

  • 조재선;이병철;정창현;김희동
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.707-712
    • /
    • 1996
  • 중대사고시 원자로 압력용기내 또는 원자로 공동(cavity) 내에서의 노심용융물은 주입되는 물로 인하여 물과 접촉하는 표면이 냉각되면서 피막층(crust)이 형성된다. 이러한 피막층의 형성은 노심용융물과 냉각수 사이의 열전달 현상에 영향을 미치며 중대사고 발생시 사고 진행에 중요한 역할을 한다. 본 연구에서는 이러한 용융물의 피막층 형성의 해석모델을 수립하기 위해 전이현상과 전도와 대류를 포함하는 2차원 열전달과 상변화를 수반하는 문제를 포함하는 운동량방정식과 에너지방정식을 2차원으로 구성하였으며 에너지방정식은 엔탈피의 함수로 나타내었다. 그리고 이러한 2차원 지배방정식을 해석하기 위해 유한차분법 및 SIMPIER 알고리즘을 이용하였다. 비교대상으로는 한국원자력연구소에서 수행한 냉각수의 비등과 기체주입 효과가 고려되지 않은 실험을 대상으로 하였다. 계산결과 용융물의 피막층은 파동(wave) 형태로 형성되었으며 일정시간이 경과하면 변화가 없는 안정한 상태가 되었다. 용융물 내에서의 온도분포는 액체상태일 경우에는 하부가열면과 상변화가 일어나는 경계면부근을 제외하고는 거의 일정한 온도분포를 나타내고 있으며 용융물이 고화된 피막층에서는 급격한 온도변화를 보여주고 있다.

  • PDF

A Study on the Optimum Design Parameters of the Thermostat for Coolant Temperature Control of an Automotive Engine (자동차용 기관의 냉각수 온도조절을 위한 서머스탯의 최적설계 변수설정에 관한 연구)

  • 박경석;신진식;원종필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.2
    • /
    • pp.1-16
    • /
    • 1993
  • It is widely recognized that exhaust emissions, fuel economy and engine torque are affected by engine temperature, and logic would suggest that a cooling system offering a better compromise of engine temperature would improve both overall engine performance and economy. Author measured coolant temperature of some parts and flow rate which are necessary to heat transfer in a engine. And Author determined parameters necessary for the optimum design of a thermostat to keep the best engine performance ; determined the optimum operating temperature of electric cooling fan. A summary of this study is followed. 1. Study of the effects of cooling condition to combustion character in a engine. 2. Analyze of heat transfer surrounding engine cylinders. 3. Study of the effects of cooling character to engine heat rejection, determination of the optimum collant temperature for keeping the optimum engine performance and determination of the optimum design of a thermostat for keeping that temperature.

  • PDF

Maximum Efficiency Point Tracking Method for Liquid Cooled Inverter (수냉형 인버터의 최대 효율 출력 추적 방법)

  • Kim, Sang-Hyun;Kim, Kwang-Seob;In, Dong-Seok;Lee, Jong-Hak;Park, Young-Min;Won, Seon-Min
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.538-539
    • /
    • 2012
  • 수냉형 인버터는 냉각 시 칠러를 사용하게 되는데 칠러는 입력 냉각수의 온도가 높을수록 열교환 효율이 높아져 소비전력이 감소한다. 하지만 인버터는 입력 냉각수의 온도가 높을수록 손실이 증가하게 되므로 수냉형 인버터는 각각의 출력 부하에 따라 최대 효율 점이 존재한다. 본 논문에서는 각각의 출력 부하에서 냉각수 온도 제어를 통해 수냉형 인버터의 최대 효율점을 추적하는 방법을 제안한다.

  • PDF

A Study on Development of Liquid Cooled Plate for Cooling of a Communication Electronic Device with High Heat Generation (고발열 통신용 전자부품 냉각을 위한 고성능 수냉식 냉각판 개발에 관한 연구)

  • Chang, G.;Park, C.M.;Kim, E.P.
    • Journal of Power System Engineering
    • /
    • v.11 no.2
    • /
    • pp.26-31
    • /
    • 2007
  • 통신용 전자기기에서 대부분의 열은 증폭기에서 발생한다. 일반적으로 증폭기를 냉각하기 위하여 공랭식을 사용하여 발생하는 많은 열을 냉각하였다. 그러나 전통적인 방법은 고성능 콤팩트화 되어가는 추세에서 발열되는 열을 충분히 냉각하기는 부족하다. 본 논문은 고발열 전자부품 냉각을 위해서 수냉식 방법을 사용하였다. 열전달 효율을 높이기 위하여 냉각판에 직접 냉각수를 흐르게하여 접촉저항을 줄였다. 그리고 냉각판의 유로에 대한 배열과 유량의 비의 효과를 조사하였다. 연구를 수행한 결과, 다음과 같은 결론을 얻을 수 있었다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 냉각 성능이 10 mm일 때보다 우수한 것으로 나타났다. 냉각수 순환량이 $3{\iota}/min$인 경우, 유로 직경이 8 mm일 때의 발열 소자 표면 온도 분포가 더욱 안정적으로 나타났으며, 상하부에 설치된 발열 소자 표면 온도가 더 낮게 나타났다. 동일한 유로 직경의 냉각판에서, 열유속 증가에 따른 냉각수의 전열 성능 증가로 인해 전체 발열량의 증가율보다 발열 소자의 온도 증가율이 낮게 나타났다.

  • PDF

생물공정의 측정 및 새로운 공정변수의 개발

  • Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.51-52
    • /
    • 2000
  • 생물공정의 운전에 있어서 적절한 공정변수가 부족한 경우가 많다. 이것은 멸균과정을 견딜 수 있는 신뢰성 높은 센서가 부족하기 때문이다[1]. 생물공정에 주로 사용되는 센서로서는 온도, pH, D.O., rpm, viscosoty 등이 있으나 이 센서들은 배양액의 물리적 혹은 화학적 상태를 측정할 수 있는 경우가 대부분이다[2]. 미생물의 대사활동과 관련이 있는 공정 변수로는 배출가스의 성분을 측정하여 얻을 수 있는 Oxygen uptake rate, Carbon dioxide evolution rate 및 Respiratory quotient가 있으며 현재 생물공정의 운전에 사용되고 있다[3]. 그러나 반복적인 센서의 보정과 연결관의 잦은 청소 및 보수를 필요로 하여 제한적으로 사용되고있는 실정이다. 자동화된 습식분석장치, Gas chromatograph, High Performace Liquid Chromatograph 혹은 Mass spectrophtometry 등을 온라인 샘플 처리장치와 연결하여 발효조의 배양액의 성분을 온라인으로 분석하고 공정의 운전에 응용하는 사례가 많이 발표되었다[4-6]. 고가의 장비 및 운전의 번거러움이나 추가적인 인력이 필요하므로 역시 특별한 경우에만 사용되고 있다. 이외에도 여러 종류의 온라인 센서 및 바이오 센서등이 개발되어 사용되고 있으나 역시 그 사용범위는 특수한 영역에 한정되어있다. 이와 같이 새로운 센서를 개발하여 공정변수를 측정하려는 시도중의 하나가 소프트웨어 센서의 개발이다. 이 것은 공정상에서 발생하는 1차 공정변수를 이용하여 배양액의 상태 혹은 2차적인 공정 변수를 추측해내는 것이다. 대부분의 경우 기존의 공정 변수를 사용하므로 추가적인 비용이 들지 않고 소프트웨어의 형태로 구현되므로 센서의 보정과 설치 및 유지관리의 노력이 매우 적은 장점이 있다. 본 연구에서는 생물공정에서 자동제어 과정에서 발생하는 여러 가지 공정상의 제어 신호로부터 새로운 공정 변수를 얻어내고자 시도하였다. 대부분의 생물공정에서는 pH의 자동제어가 필수적인데 자동제어 과정에서 발생하는 pH 제어 신호 및 pH의 변화 응답신호를 이용하여 배지의 완충용량의 변화와 알칼리의 소비속도를 온라인으로 측정할 수 있었다. 여기에 인공지능망을 설계하여 균체의 량을 온라인으로 추정하는 방법을 개발하였다 [7].산업용 발효조의 운전 온도는 주로 냉각수의 단속적인 공급에 의하여 항상 일정하게 조절된다. 따라서 냉각수의 냉각량을 측정하면 미생물의 배양시 발생하는 대사열량을 측정할 수 있게 된다. 본 연구에서는 실험실의 발효조를 냉각수의 단속적인 공급에 의하여 자동온도 조절이 되도록 개조하고 여기에 냉각수의 유출입 지점에 온도센서를 부착하여 냉각수의 온도를 측정하고 냉각수의 공급량과 대기의 온도 등을 측정하여 대사열의 발생을 추정할 수 있었다. 동시에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.

  • PDF

Breakdown Characteristic of Coolant for Hydrogen Fuel Cell by Thermal Aging (열 열화에 의한 수소 연료전지용 냉각수의 절연파괴 특성)

  • Kim, Yoon-Hyoung;Choi, Kang-Wal;Han, Sang-Ok;Lee, Sei-Hyun;Yong, Gee-Joong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2132-2133
    • /
    • 2011
  • 본 논문에서는 차량용 수소 연료전지 냉각수의 절연열화특성을 평가하기 위해 냉각수 시료에 대해 운전온도 보다 가혹한 열 열화 조건을 인가하여 그 특성을 평가하였다. 연료전지 냉각수의 절연열화기구는 냉각수 내 이온성 불순물 증가로 인한 도전율 상승, 유기물 성분의 열열화로 인한 절연저항 및 유전특성 변화 등으로, 이는 연료전지 차량의 절연저항 저하 등의 문제를 야기시킬 수 있다. 본 논문에서는 이온성 불순물에 의한 국부적인 절연특성을 평가 하기 위해 상용 전기전도도미터를 이용한 비전도도 측정 및 열열화로 인한 유기물 성분인 절연성 부동액의 유전특성 변화를 진단하여 열 열화된 냉각수의 전기전도도 및 전기용량 특성을 평가하였다. 또한 각 시료에 대한 내전압 시험을 진행하여 열 열화와 절연파괴 특성의 관계를 확인하였다.

  • PDF

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.