• 제목/요약/키워드: 냉각(cooling)

검색결과 3,156건 처리시간 0.028초

전자장비 캐비넷의 냉각특성에 관한 실험적 연구 (An experimental study on the cooling characteristics of electronic cabinet)

  • 박종흥;이재헌
    • 대한기계학회논문집B
    • /
    • 제20권7호
    • /
    • pp.2356-2366
    • /
    • 1996
  • High-power electronic chips have been advanced to such an extent that the heat dissipation capability of a system design has become one of the primary limiting factors. Therefore, thermal design must be considered in the early stage of the electronic system development. In present paper, the results of an experimental study on the forced convection cooling are presented to evaluate cooling performance of an electronic cabinet which in generally used for telecommunication system. Temperatures and thermal resistances are applied to compare the heat transfer characteristics for various locations of a fan unit as well as various configuration of non-uniform powering modules. As a result, the optimal configuration of a fan unit and powering configuration is suggested for the effective thermal design of telecommunication system.

경사면에서의 분무냉각 막비등 열전달에 관한 실험적 연구 (Experimental Study on Film Boiling Heat Transfer of Spray Cooling for Inclined heat transfer Surface)

  • 김영찬
    • 설비공학논문집
    • /
    • 제22권1호
    • /
    • pp.33-39
    • /
    • 2010
  • The film boiling heat transfer was experimentally investigated for the water sprays impacting on an inclined hot surface. Full cone spray nozzles were employed for the spray cooling experiment, and experiments were made for different inclination angles of $\theta=0^{\circ}$, $15^{\circ}$, $30^{\circ}$ and $45^{\circ}$. The experimental results show that, in the downstream region of the inclined hot surface, increasing the inclination angle increases the local heat flux slowly because of increasing the number of rebound droplets. However, the inclination angle of heat transfer surface had no remarkable effect on the local heat flux of spray cooling under the present test conditions.

정밀 오일냉각기의 오일온도 제어오차에 관한 연구 (A Study on the Oil Temperature Control Errors of Precision Oil Coolers)

  • 이상호;이찬홍;김갑순
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.451-454
    • /
    • 2003
  • The Oil Coolers is very important unit for the stable thermal performance in machine tools, semiconductor equipments and high precision measuring systems. To select a proper oil cooler for the temperature control of core unit in a machine, not only cooling ability but also static and dynamic sensitivity of temperature sensors are considered. In this paper, the relationship between cooling ability and inflow oil temperature is identified. The cooling ability is increased with the increase of inflow oil temperature. The oil temperature control errors of a cooler are influenced by mainly sensitivity of temperature sensors and heating velocity in a machine. The validity of error cause analysis for temperature control is proved by real cooling experiments with inflow and outflow temperature sensors.

  • PDF

평판 분무냉각 시의 고온역 열전달계수에 관한 연구 (A Study on the High Temperature Region Heat Transfer Coefficients for the Spray Cooling of Hot Flat Plates)

  • 윤두호;오철;윤석훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.25-32
    • /
    • 2000
  • In this paper, experiments investigating the high-temperature region heat transfer coefficients for the spray cooling of hot flat plates were performed by down spray water using flat spray nozzles. The heat transfer surface is made of copper and is 100mm in length and 40mm in width and 15mm in thickness. The experimental condition of spray are as follows: temperatures of the water droplets are T=20~$80^{\circ}C$ and droplets volume fluxes are D=0.001565~0.010438$m^3/m^2s$. Next, correlating equations for the heat transfer characteristics of spray cooling in the high temperature region are developed from the effects of droplets volume flux and the surface temperature of heat transfer plate.

  • PDF

세탁기용 유도모터의 냉각에 관한 수치적 연구 (Numerical Study on the Cooling of Induction Motor In a Washing Machine)

  • 홍상욱;전시문
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.266-271
    • /
    • 2003
  • The numerical study was carried out to effectively cool Induction motor applied to a washing machine. The outer rotor made of steel periodically spins up and down. The stator consists of the thin layered iron plates and copper coil. The effective cooling system is necessary to solve the reliability problem caused by the electric losses at the coil and the iron plate. Because the heat transfer rate of the natural convection in partially open space is generally low, thus it is necessary to enhance the heat transfer using rotating perforated plate. The flow phenomena around the motor are very complex due to the motor geometry and the outer rotor motion. The mixed convection takes place due to the slow rotation speed. The three dimensional flow simulation was performed using rotating reference frame technique and Boussinesq approximation but the radiation effect was neglected. It was found that the angle and direction of the cooling blades play an important role in the stator temperature.

  • PDF

Cold plate를 이용한 휴대용 컴퓨터 냉각 시스템의 열성능에 관한 연구 (A Study on Thermal Performance of Cooling System for a Laptop Computer Using a Cold Plate)

  • 박상희;조남해;최성대
    • 한국기계가공학회지
    • /
    • 제8권4호
    • /
    • pp.83-89
    • /
    • 2009
  • This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.

  • PDF

기계통풍식 냉각탑 유닛의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Cooling Tower Unit for Mechanical Draft)

  • 정순영
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.642-648
    • /
    • 2021
  • In this paper, an experimental study was conducted on the performance of the cooling tower. In order to improve reliability in the cooling tower performance test, the measurement uncertainty of the instrument was estimated. Measurement uncertainty refers to the uncertainty of a measurement, estimates the range in which the expected value of the measurement can be within a certain confidence level, and suggests a range in which the measured representative value is incorrect. Therefore, the measurement result of the performance experiment is not an actual value, but a reasonable estimated value. The measurement uncertainty for the test was calculated and the measured results were presented.

청송 주왕산 북부 일대의 구과상 유문암에 대한 연구 (The Study on the Spherulitic Rhyolites in the northern part of Juwang Mt., Cheongsong)

  • 오창환;김성원;황상구;손창환;김창숙;김형식
    • 암석학회지
    • /
    • 제13권2호
    • /
    • pp.103-118
    • /
    • 2004
  • 청송 지역에서는 국내외적으로 희귀하며 매우 다양하고 아름다운 형태를 보여주는 구과상 유문암들이 맥의 형태로 산출된다. 청송 구과상 유문암내에 나타나는 섬유상 광물은 이들 암맥이 지표근처에서 빠르게 냉각되었음을 지시하며 청송 구과강 유문암의 다양한 형태는 각 맥의 냉각속도의 다양함에 기인한다. 구과상 유문암의 형태는 성인에 따라 방사상 단식,층상 단식, 층상 복식, 방사상-층상 복식, 방사층상 복식의 5가지로 분류된다. 방사상 단식 구과형과 방사층상 복식 구과형은 상대적으로 가장 빠른 냉각시 과냉각에 의한 확산류에 의해 형성되었으며 냉각속도가 상대적으로 가장 느린 경우 리제강 링의 형성 원리와 같은 방식으로 상대적으로 느린 확산에 의해 층상형 복식 구과형이 형성되었다. 그리고 냉각속도가 중간일 경우 층상 단식 구과형이 생성된다. 따라서 청송 지역의 구과상 유문암중 방사상 단식 혹은 방사층상 복식 구과형인 국화형, 민들레형, 해바라기형, 다알리아형은 가장 빠르게 냉각된 암맥에서 생성된 반면 층상형 복식 구과형인 장미형, 무명형과 목단형등은 상대적으로 가장 천천히 냉각된 암맥으로 부터 형성되었다. 그리고 매화형과 같은 층상단식 구과형은 상대적으로 중간 속도의 냉각 속도를 갖는 맥에서 산출된다. 구과상 유문암 맥들의 K-Ar 전암 연령은 이들 암석이 48-50Ma에 관입한 암체임을 지시한다 청송지역의 구과상 유문암은 그 희귀성과 다양하며 아름다운 형태 때문에 연구 및 보존가치가 높다.

실물형 액체로켓엔진 연소기 물냉각 연소시험 성능결과 (Combustion Performance of a Full-scale Liquid Rocket Thrust Chamber Using Water as Coolant)

  • 한영민;김종규;문일윤;이광진;서성현;최환석;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.187-192
    • /
    • 2006
  • 본 논문에서는 추력 30톤급 액체로켓엔진의 실물형 연소기 물냉각 연소시험 성능결과에 대해 기술하였다. 연소기 연소압력은 53bara 그리고 추진제 유량은 90kg/s이다. 30톤급 실물형 연소기에 대한 첫 채널 냉각 연소시험인 관계로 연소실 채널로 냉각수 물을 케로신 설계 냉각 체적 유량의 110%인 35kg/s와 케로신 냉각과 비슷한 성능을 갖는 유량 18kg/s에 대한 연소시험을 수행하였다. 각각의 연소시험 결과에 대해 기술하였으며, 채널 냉각 연소실에서 냉각 성능이 충분해 케로신 냉각 연소시험이 가능하다는 것을 알 수 있었다.

  • PDF

항공기용 가스터빈의 고압 냉각터빈 노즐에 대한 복합열전달 해석 (Conjugate Heat Transfer Analysis for High Pressure Cooled Turbine Vane in Aircraft Gas Turbine)

  • 김진욱;박정규;강영석;조진수
    • 한국유체기계학회 논문집
    • /
    • 제18권2호
    • /
    • pp.60-66
    • /
    • 2015
  • Conjugate heat transfer analysis was performed to investigate the flow and cooling performance of the high pressure turbine nozzle of gas turbine engine. The CHT code was verified by comparison between CFD results and experimental results of C3X vane. The combination of k-${\omega}$ based SST turbulence model and transition model was used to solve the flow and thermal field of the fluid zone and the material property of CMSX-4 was applied to the solid zone. The turbine nozzle has two internal cooling channels and each channel has a complex cooling configurations, such as the film cooling, jet impingement, pedestal and rib turbulator. The parabolic temperature profile was given to the inlet condition of the nozzle to simulate the combustor exit condition. The flow characteristics were analyzed by comparing with uncooled nozzle vane. The Mach number around the vane increased due to the increase of coolant mass flow flowed in the main flow passage. The maximum cooling effectiveness (91 %) at the vane surface is located in the middle of pressure side which is effected by the film cooling and the rib turbulrator. The region of the minimum cooling effectiveness (44.8 %) was positioned at the leading edge. And the results show that the TBC layer increases the average cooling effectiveness up to 18 %.