Abstract
This study investigates two-phase cooling system of close-loop by using FC-72 and PCM(Phase change material). The cooling system consists of evaporator, cold plate, micro pump, and condenser. The heat input on the performance of evaporator is appreciated by visualizing the boiling on the evaporator. The heat performance of cooling system is investigated to determine the effects of volume fill ratio change at working fluid, pump flow rate change, and volume fill ratio change at PCM in cold plate. Experimental results show the ideal condition when the volume ratio of working fluid, the pump flowing, and the volume ratio of PCM are 60%, 6ml/min, and 60% respectively.