• Title/Summary/Keyword: 내구 성능

Search Result 1,230, Processing Time 0.027 seconds

Position-Dependent Cathode Degradation of Large Scale Membrane Electrode Assembly for Direct Methanol Fuel Cell (직접 메탄올 연료전지용 대면적 막-전극 접합체 공기극의 위치별 열화 현상)

  • Kim, Soo-Kil;Lee, Eun-Sook;Kim, Yi-Young;Kim, Jang-Mi;Joh, Han-Ik;Ha, Heung-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.12 no.2
    • /
    • pp.148-154
    • /
    • 2009
  • With respect to the durability of large scale ($150cm^2$) membrane electrode assembly (MEA) of direct methanol fuel cell (DMFC), degradation phenomena at cathode is monitored and analyzed according to the position on the cathode surface. After constant current mode operation of large scale MEA for 500 hr, the MEA is divided into three parts along the cathode channel; (close to) inlet, middle, and (close to) outlet. The performance of each MEA is tested and it is revealed that the MEA from the cathode outlet of large MEA shows the worst performance. This is due to the catalyst degradation and GDL delamination caused by flooding at cathode outlet of large MEA during the 500 hr operation. Particularly on the catalyst degradation, the loss of electrochemically active surface area (ECSA) of catalyst gets worse along the cathode channel from inlet to outlet, of which the reason is believed to be loss of catalysts by dissolution and migration rather than their agglomeration. The extent of loss in the performance and catalyst degradation has strong relation to the cathode flooding and it is required to develop proper water management techniques and separator channel design to control the flooding.

Evaluation on the Mechanical Performance of Concrete Using Entanglement Polyamide Fiber (다발형 폴리아미드섬유 보강 콘크리트의 역학적 성능평가)

  • Jeon, Joong Kyu;Kim, Gyu Yong;Jeon, Chan Ki;Lee, Soo Choul
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.3
    • /
    • pp.223-233
    • /
    • 2012
  • Steel fiber is high stiffness and large weight. So, Pumping hose to rupture of the safety management is difficult. Steel fiber caused by corrosion of the deterioration of durability and high-rebound losses are needed for the improvements. Thus, the revised regulations in 2009 by a steel fiber to reinforce other materials is possible. Variety of fiber reinforcement material for concrete review of applicability is needed. Steel fiber strength than the other fibers is large and by the geometry of the fibers are attached to improve performance. However, compared to steel fiber organic fibers and low modulus of elasticity and tensile strength of fiber and agglomeration occurs in the concrete to be used as reinforcement material is difficult. In this regard, the present study as a single object in the micro-fiber bouquet sharp entanglement through make muck attach surface area, distributed fibers from surfactant of the surface enhanced polyamide fibers, steel fiber and PP fiber reinforced concrete by comparing the scene to provide a basis for the use.

Flexural Behavior of High-Strength Reinforced Concrete Beam with Recycled Aggregate Strengthened by FRP Plate (FRP로 보강된 순환골재 고강도 철근콘크리트 보의 휨거동)

  • Hong, Seong-Uk;Lee, Seung-Ho;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.126-132
    • /
    • 2018
  • As means to increase the use of concrete with recycled coarse aggregate (RCA), this study aims to evaluate the applicability for flexural strengthening of reinforced concrete beam with high-strength concretes and RCA on which FRP plates, used for repair and strengthening of old and low-durability reinforced concrete structures, is applied. In order to increase the adhesive force of epoxy and FRP plate, FRP plate was installed according to Near-Surface-Mounted (NSM) method. 12 specimens were manufactured using substitution rate of RCA (30%), concrete strengths (40MPa, 60MPa), diameters of deformed bar (D10, D13), and types of FRP plate (AFRP, CFRP) as variables to analyse flexural performance according to FRP plate and substitution rate of recycled aggregate. As a result, in all specimens, specimens strengthened by FRP plate showed a maximum of 17% increase in performance compared to specimens without FRP plate and strengthening performance of CFRP was found to be higher than AFRP. When modulus of rupture was used, the value of cracking moment was similar to that of the reference equation. As bending moment of some specimens strengthened by FRP plate failed to satisfy the criteria of KCI 2012 and ACI 440-2R, additional experiment is deemed as necessary.

Multiscale Virtual Testing Machines of Concrete and Other Composite Materials: A Review (콘크리트 및 복합재료용 멀티스케일 가상 시험기계에 관한 소고)

  • Haile, Bezawit F.;Park, S.M.;Yang, B.J.;Lee, H.K.
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.4
    • /
    • pp.173-181
    • /
    • 2018
  • Recently composite materials have dominated most engineering fields, owing to their better performance, increased durability and flexibility to be customized and designed for a specific required property. This has given them unprecedented superiority over conventional materials. With the help of the ever increasing computational capabilities of computers, researchers have been trying to develop accurate material models for the complex and integrated properties of these composites. This has led to advances in virtual testing of composite materials as a supplement or a possible replacement of laboratory experiments to predict the properties and responses of composite materials and structures. This paper presents a review on the complex multi-scale modelling framework of the virtual testing machines, which involve computational mechanics at various length-scales starting with nano-mechanics and ending in structure level computational mechanics, with a homogenization technique used to link the different length scales. In addition, the paper presents the features of some of the biggest integrated virtual testing machines developed for study of concrete, including a multiscale modeling scheme for the simulation of the constitutive properties of nanocomposites. Finally, the current challenges and future development potentials for virtual test machines are discussed.

An Performance Evaluation of the Post-installed Anchor System According to the Freezing and Thawing of Concrete and the Corrosion of Anchor (콘크리트의 동결융해와 앵커의 부식에 따른 후 설치 앵커시스템의 성능평가)

  • Kwon, Min-Ho;Kim, Jin-Sup;Jung, Woo-Young;Kwon, Sang-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.31-39
    • /
    • 2013
  • In this study, performance of the post-installed anchor system was evaluated with reduced strength of concrete and anchor. One of the post-installed anchors was selected to performance evaluation. Concrete strength was reduced by freeze-thawing test, and the post-installed anchor strength was reduced by corrosion test. The post-installed Anchor was installed in concrete of freezing and thawing and original concrete, and corroded anchor was installed in original concrete only. Anchor diameter and installation depth of the anchor were the variable for each specimen. Performance of post-installed anchor system of each specimen was evaluated by pullout test. Anchor diameter and installation depth of anchor, it may affect the performance of the post-installed anchor system from the experimental test results. Fracture mode of each post-installed anchor system had occurred differently depending on the durability of concrete and anchor. The anchor pullout strength from the experimental test results was used in order to compare with the results of CCD (Concrete Capacity Design) method, and CCD equation was modified. Modified equation was able to predict the anchor pullout strength of post-installed anchor system in Original concrete and freezing and thawing of concrete.

Properties of SPE-Based Cement Grout for Semi-Rigid Pavements (Sulfur Polymer Emulsion을 활용한 반강성 포장용 시멘트 주입재의 특성)

  • Lee, Byung-Jae;Lee, Jun;Hyun, Jung-Hwan;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.57-65
    • /
    • 2013
  • The development of the oil refining industry has resulted in an annual 120 million tons of sulphur, which is a by-product of the desulphurization process. To exploit this abundance, the applications of sulphur must be expanded. as excellent durability of reuse of leftover sulphur which has high potential for utilization in construction materials, the study is actively in progress. Meanwhile, there has been active research on semi-rigid pavements that draw on the strengths and overcome the weaknesses of asphalt and concrete pavements. Acrylate is used to prevent cracking but involves a high cost, thus, an alternative material is required. As such, this study presents methods on the reuse of leftover sulphur and examines the engineering performance of grout containing sulfur polymer emulsion (SPE) for use in semi-rigid pavements. Our analysis shows that grout in which 30% of acrylate is replaced with SPE has superior properties in terms of time of flow and strength compared to regular grout. However, performance declined when more than 50% of acrylate was replaced by SPE, indicating that the optimum replacement level is 30%. Through SEM analysis, we found that grout with utra harding cement in this study at three hours had similar hydration properties to that of Type 1 Ordinary Portland Cement (OPC) at seven days, and maintained the properties regardless of grout containing SPE. OPC and grout with a replacement level of 30% displayed similar levels of chloride invasion resistance, whereas grout without SPE was far less resistant. Within the scope of this paper, the optimum replacement level of acrylate with SPE was found to be 30% in consideration of various properties such as time of flow, strength, and chloride invasion resistance.

Improvement of Flight Safety on Configuration Change of Rotorcraft Wiper Arm (회전익 항공기의 와이퍼 암 형상변경을 통한 비행 안전성 향상)

  • Kim, Dae-Han;Lee, Yoon-Woo;An, Jeong-Min;Park, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.736-741
    • /
    • 2017
  • This paper examines the design for improving the wiper system of rotorcraft. During rotorcraft operation, the wiping performance and excessive clearance can decrease. The wiper system consists of a wiper arm assembly, motor, convertor and flex drive. If there is a problem with the wiper system, the operation ability decreases because the operation is restricted in a rainy environment. There are two main causes of the problem of the wiper system: the lifting forces acting on the wiper arm in aircraft flight and the excessive gap of the components. To remedy these two problems, the wiper arm was improved. The improvements included increased contact pressure on the wiper arm (spring tension), improved gear clearance, and material and shape changes. Durability test, aircraft ground test and flight test were carried out to verify the improved shape, and it was confirmed that the wiping performance and clearance problems were solved. Currently, the rotorcraft is operated without problem by applying the improved shape, and this design improvement process will be a useful reference for future rotorcraft development.

Analysis of breaching behavior of levee according to coating thickness of new substance (신소재의 피복두께에 따른 제방의 붕괴 거동 분석)

  • Ko, Dong Woo;Kim, Sung Joong;Kang, Joon Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.480-480
    • /
    • 2018
  • 전 세계적으로 자연 친화, 하천생태계 보전, 친수하천 등을 조성하기 위한 대대적인 하천 정비사업이 활발히 진행 중에 있다. 최근 홍수로 인한 제방 붕괴에 대응하기 위한 제방의 안정화 및 개선을 위한 방법으로 기존의 시멘트와 같은 혼합물질을 사용하지 않고 환경 친화적이고 지속 가능한 대안에 대한 수요가 증가되고 있는 추세이며 현재 노후화 된 불안정 제방에 대한 보강대책을 수립해나가는 과정으로써 친환경 신소재를 활용하여 제방을 보호하는 연구가 수행되고 있다. 제방사면에 적용되는 신소재는 바이오폴리머를 활용한 재료로써 공동연구기관 카이스트에서 개발된 환경 친화적인 물질로 미생물에 의해 유도된 고인장 및 인체 무해성 등의 특성을 갖고 있으며 경제적 타당성인 측면에서 시멘트와 비교 분석 되어야 하고 실제 현장에서의 적용 가능성, 신뢰성 및 내구성 검토 등 성능을 보장하기 위한 지속적인 연구가 필요한 상황이다. 이에 본 안동하천실험센터에서는 중규모 제방을 직접 제작하여 수리모형실험을 통한 친환경 신소재 활용 제방의 안정성 및 성능 평가를 실시하였다. 수리실험 조건은 카이스트에서 제시된 레시피를 기반으로 먼저 분말형태의 바이이폴리머를 물과 희석하여 만들어진 바이오폴리머 용액을 흙과 혼합한 뒤 제방표면에 직접 미장작업을 수행하여 실험조건에 따라 일정한 두께(1cm, 3cm, 5cm)로 피복하였다. 이후 월류 붕괴 실험이 가능한 3 - 5일 정도의 양생기간을 거쳐 실험을 진행하였다. 실험결과는 다수의 고프로(GoPro) 및 비디오 카메라 등 다양한 영상장치를 이용하여 픽셀기반의 영상분석기법을 활용한 시간 흐름에 따른 제방 사면에서의 붕괴규모를 산정하여 신소재의 피복 두께에 따른 제체의 붕괴 거동 및 안정성을 평가하였으며, 또한 제방 파괴부에서의 흐름 상황 및 유속이 붕괴 발달에 미치는 영향을 분석하기 위하여 PIV 분석을 실시하였다. 이번 연구의 최종목표는 지속적인 예비실험을 수행하여 월류 및 침투, 파이핑 등 파괴 인자 별 신소재의 성능 개선 및 개발된 새로운 공법에 대한 효과 검토를 통한 최적안을 도출함으로써 향후 실규모 실험실증을 통한 신소재 시공 및 공법에 대한 현장적용 가능성 검증을 거쳐 최종적으로 신소재 제방 공법 설계 기술, 신소재 및 공법 표준안, 제방공법 안정성 평가 가이드라인 등을 제시하고자 하며, 이러한 실험데이터를 축적함으로써 실제 제방 붕괴 시 비상대처계획 수립에 필요한 기초자료로 활용이 가능할 것으로 사료된다.

  • PDF

Effect of SUS316L Bipolar Plate Corrosion on Contact Resistance and PEMFC Performance (SUS316L 분리판 부식에 의한 접촉저항 및 고분자전해질 연료전지 성능에 미치는 영향)

  • Kim, Junseob;Kim, Junbom
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.664-670
    • /
    • 2021
  • Stainless steel was applied as bipolar plate (BP) of polymer electrolyte membrane fuel cell (PEMFC) due to high mechanical strength, electrical conductivity, and good machinability. However, stainless steel was corroded and increased contact resistance resulting PEMFC performance decrease. Although the corrosion resistance could be improved by surface treatment such as noble metal coating, there is a disadvantage of cost increase. The stainless steel corrosion behavior and passive layer influence on PEMFC performance should be studied to improve durability and economics of metal bipolar plate. In this study, SUS316L bipolar plate of 25 cm2 active area was manufactured, and experiments were conducted for corrosion behavior at an anode and cathode. The influence of SUS316L BP corrosion on fuel cell performance was measured using the polarization curve, impedance, and contact resistance. The metal ion concentration in drained water was analyzed during fuel cell operation with SUS316L BP. It was confirmed that the corrosion occurs more severely at the anode than at the cathode for SUS316L BP. The contact resistance was increased due to the passivation of SUS316L during fuel cell operation, and metal ions continuously dissolved even after the passive layer formation.

Feasibility of Economic Analysis of Riverfront Facility Based on Mobile Big Data (통신 빅데이터 기반 하천이용시설 사용성능 경제성평가기법개발)

  • Choi, Byeong Jun;Noh, Hee-Ji;Bang, Young Jun;Lee, Seung Oh
    • Journal of Korean Society of Disaster and Security
    • /
    • v.14 no.3
    • /
    • pp.29-38
    • /
    • 2021
  • Riverfront facilities are river space facilities used by citizens for the rest and convenience. Recently, although the importance of efficient maintenance of riverfront facilities is increasing, damaging facilities cases are increasing due to frequent floods. Currently, the inspections and diagnosis of river space facilities are limited to the main flood control facilities. And the standards for the maintenance and management of the riverfront facilities are insufficient. Utilization survey, which is the standard for managing river space facilities, is also inefficient in terms of manpower consumption and economic feasibility. This study uses mobile big data to classify river usage and conducts a survey for usability of river facilities to derive economic evaluation for usage performance. In the future, if economical method system that considers safety, usability, and durability is conducted and demanding analysis for each convenience facility is evaluated, it is expected that the efficient maintenance of riverfront facilities is perfomed better and the use of rivers by citizens will further increase.