An Performance Evaluation of the Post-installed Anchor System According to the Freezing and Thawing of Concrete and the Corrosion of Anchor

콘크리트의 동결융해와 앵커의 부식에 따른 후 설치 앵커시스템의 성능평가

  • 권민호 (경상대학교 토목공학과 공학연구원) ;
  • 김진섭 (경상대학교 토목공학과) ;
  • 정우영 (강릉원주대학교 토목공학과) ;
  • 권상원 (경상대학교 토목공학과)
  • Received : 2013.03.12
  • Accepted : 2013.05.13
  • Published : 2013.09.30

Abstract

In this study, performance of the post-installed anchor system was evaluated with reduced strength of concrete and anchor. One of the post-installed anchors was selected to performance evaluation. Concrete strength was reduced by freeze-thawing test, and the post-installed anchor strength was reduced by corrosion test. The post-installed Anchor was installed in concrete of freezing and thawing and original concrete, and corroded anchor was installed in original concrete only. Anchor diameter and installation depth of the anchor were the variable for each specimen. Performance of post-installed anchor system of each specimen was evaluated by pullout test. Anchor diameter and installation depth of anchor, it may affect the performance of the post-installed anchor system from the experimental test results. Fracture mode of each post-installed anchor system had occurred differently depending on the durability of concrete and anchor. The anchor pullout strength from the experimental test results was used in order to compare with the results of CCD (Concrete Capacity Design) method, and CCD equation was modified. Modified equation was able to predict the anchor pullout strength of post-installed anchor system in Original concrete and freezing and thawing of concrete.

본 연구에서는 콘크리트 강도와 앵커의 강도 변화에 따른 앵커시스템의 성능을 평가하였다. 성능평가를 위하여 후 설치 앵커의 한 종류인 Set Anchor를 선정하였다. 동결융해 시험을 통하여 콘크리트의 강도를 감소시켰고, 부식을 통하여 앵커의 강도 감소를 고려하였다. 설치 앵커인 Set Anchor를 동결융해 된 콘크리트와 일반 앵커를 설치하고, 일반 콘크리트에 부식된 앵커를 설치하여 콘크리트 내력에 따른 인발 내력을 고찰 하였다. 각 시험체별로 앵커의 직경, 앵커의 근입 깊이를 변수로 설정하였다. 실험결과 인발 하중을 받는 경우에는 앵커의 직경 및 근입 깊이에 영향이 있는 것으로 나타났다. 인발 실험시 콘크리트 콘 파괴 및 뽑힘파괴 등 콘크리트와 앵커의 내구성에 따라 파괴모드가 다르게 발생하였다. 또한 앵커의 인발 내력을 CCD (Concrete Capacity Design)방법을 사용한 결과와 비교 평가하여 새로운 수정식을 제안하였으며, 수정식을 사용하여 일반 및 동결융해 콘크리트에 설치된 앵커의 인발 내력을 예측 할 수 있었다.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. ACI Committee 349, "Code Requirements for Nuclear Safety Related Concrete Structures (ACI 349-90)", American Concrete Institute, Detroit.
  2. Chung, L., Won, J. H., Cho, S. H., "Structural Performance of Reinforced Concrete Columns due to Corroded Main and Hoop Bars", Architectural Institute of Korea, Vol. 20, No. 3, 2004, pp.3-10 (in Korean).
  3. Hwang, H. J., Park, D. C., Oh, S. G., "Durability Life Prediction of Concrete Subjected to Freezing-Thawing and Chloride Attack", The Korea Institute of Building Construction, Vol. 8, No. 2, 2008, pp.97-101 (in Korean). https://doi.org/10.5345/JKIC.2008.8.1.097
  4. Kim, H. U., Jee, N. Y., "Effect of the Rebar Corrosion Rate on Bond Strength in Reinforced Concrete - factors caused by compressive strength and embedded rebar condition", Architectural Institute of Korea, Vol. 21, No. 11, 2005, pp.159-166 (in Korean).
  5. Kim, J. S., Kwon, M. H., Seo, H. S., Park, J. H., "Performance Evaluation and Analysis Model for the Post-Installed Anchor", Journal of KOSHAM, Vol. 13, No. 2, Apr. 2013, pp.089-095 (in Korean). https://doi.org/10.9798/KOSHAM.2013.13.2.089
  6. Kim, S. Y., Seo, S. Y., Kim, K. S., "Tensile Strength of Expansion Anchors installed in Uncracked and Unreinforced Concrete", Architectural Institute of Korea, Vol. 19, No. 11, 2003, pp.83-92 (in Korean).
  7. Kim, Y. H., You, S. G., "Evaluation and Application of Pullout Strength of Single Anchor in Plain Concrete According to Edge Distance", Journal of the Korea Institute for Structural Maintenance Inspection, Vol. 8, No. 1, 2004, pp.211-220 (in Korean).
  8. Oh, S. G., "The Change of Chloride Attack Resistibility of Concrete Damaged Due to Freezing-Thawing", Architectural Institute of Korea, Vol. 25, No. 4, 2009, pp.169-176.
  9. Seo, S. Y., Yoon, S. J., Kim, S. S., Yoon, Y. D., "An Experimental Study on the Pull-out Strength of Post-Installed Anchor Bolt", The Regional Association of Architectural Institute of Korea, Vol. 2, No. 1, 2006, pp.359-362 (in Korean).
  10. Summary of the KCI code, the Korea Concrete Institute, 2012.

Cited by

  1. A Study on Adhesion Behavior of CFRP Composite Plate Attached on the RC Beams by Freezing and Thawing vol.11, pp.2, 2020, https://doi.org/10.11004/kosacs.2020.11.2.001
  2. Evaluation of Behavior Characteristics of Reinforced Concrete Beam Structures by Freeze-thawing vol.11, pp.2, 2013, https://doi.org/10.11004/kosacs.2020.11.2.039