• Title/Summary/Keyword: 난방 시간

Search Result 138, Processing Time 0.045 seconds

Heating Effect by Electric Radiator in Greenhouse of Chrysanthemum Cultivation (전기 방열기가 국화재배온실의 난방에 미치는 영향)

  • Suh, Won-Myung;Leem, Jae-Woon;Kim, Young-Ju;Min, Young-Bong;Kim, Hyeon-Tae;Huh, Moo-Ryong;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.44 no.4
    • /
    • pp.79-85
    • /
    • 2010
  • An analysis in heating effects of an electric radiator located in a 1-2W type chrysanthemum (3 cultivars) cultivation greenhouse installed in Gyeongsang National University drew the following conclusions. During the experiment period, the highest, average, and the lowest outside temperatures were in the ranges of $-3.8{\sim}21.3^{\circ}C$, $-5.2{\sim}16.1^{\circ}C$ and $-12.5{\sim}14.4^{\circ}C$, respectively, and the average relative humidity inside and outside the greenhouses were in the ranges of 43.5~98.6% and 35.2~100%, respectively. From mid-December to early February, the lowest outside temperature was recorded as approximately $-5.0{\sim}-10.0^{\circ}C$, which showed that it tended to be relatively lower than the temperatures recorded at the Jinju Meteorological Observatory. During the night, the leaf temperature measured directly under the radiator tended to be higher by $2{\sim}3^{\circ}C$ than that those at the middle point of the radiator, or higher by a negligible amount. In the case of root zone temperature, it was found that there was almost no difference between temperatures of the part directly under and the middle point, and the time when the highest temperature of root zone and other highest temperatures took place showed that there was about a 2-hour delay phenomenon. The total electricity consumption, energy supply and total heating cost during the experiment period were 2,800 kWh, 2,408,000 kcal and 112,000 won, respectively. When diesel, a kind of fossil fuel, was used as heating oil, the total heating cost was around 224,500 won. It was estimated that the total heating cost could be reduced by around 50% if a radiator was used.

Experimental Study on Consumption of Energy and Heating Efficiency in Floor Water Heating System on Using Ondol Panel of Double Metal Rendering (이중금속융출형 온돌판넬을 이용한 바닥온수난방시스템의 난방성능과 에너지소비량에 관한 실험적 연구)

  • Bai, Dai-Kwon;Kim, Jin-Bong;Kim, Hwan-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6167-6175
    • /
    • 2012
  • This study is experimental analysis to verify heating efficiency of Ondol in floor heating panel developed. For this one, an experiment tests producing an each test speciment and measuring heating efficiency. The result of an experiment, supplying hot water temperature is $45^{\circ}C$ and the result of measuring on parts temperature of test speciment on supplying for 8 hours, mortar surface that is superstructure plumbing of heating system developed is $49.4^{\circ}C$, the gap of piping on center of mortar surface is $44.1^{\circ}C$ and airspace is proved $25.3^{\circ}C$. In floor structure of standards, mortar surface is $46.2^{\circ}C$, the gap of piping on center of mortar surface $37.7^{\circ}C$ and airspace is $24.7^{\circ}C$. On the other hand, energy consumption accumulating of development technology is identified, in case of hot-water supply on $45^{\circ}C$ as 4,646 kcal and in existing technology, as 4,814 kcal. developing technology is verified and lower than existing technology.

Design of thermal system using 3-way valve and PTC to which a solar module (태양광 모듈이 부착된 PTC 집열기 및 3웨이 밸브를 이용한 온열 시스템 설계)

  • Song, Je-Ho;Lee, In-Sang;Lee, You-Yub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.454-459
    • /
    • 2017
  • In this study, a thermal system was designed using a 3-way valve and PTC attached to a solar module. This design could help solve the problem of rising fossil fuel costs caused by limited reserves and environmental problems resulting from fossil fuel use. The thermal system is a hot-air and heating control system composed of a temperature sensor part, mode setting part (for hot air and heating modes), supply part, and thermal system control part. The temperature sensor part has piping and an indoor temperature display, and the temperature setting part has multiple monitoring functions. The mode setting part switches between hot air and heating modes and can be used to set the temperature. The thermal system control part performs functions such as PTC control and temperature setting, PTC day and night and time selection, hot air and heating control, and three-way valve selection. The results verify that the system operates with stable response speeds of $680{\mu}s$ in the temperature sensor part, $700{\mu}s$ in the mode setting part, and $610{\mu}s$ in the thermal system control part.

Outside Temperature Prediction Based on Artificial Neural Network for Estimating the Heating Load in Greenhouse (인공신경망 기반 온실 외부 온도 예측을 통한 난방부하 추정)

  • Kim, Sang Yeob;Park, Kyoung Sub;Ryu, Keun Ho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.7 no.4
    • /
    • pp.129-134
    • /
    • 2018
  • Recently, the artificial neural network (ANN) model is a promising technique in the prediction, numerical control, robot control and pattern recognition. We predicted the outside temperature of greenhouse using ANN and utilized the model in greenhouse control. The performance of ANN model was evaluated and compared with multiple regression model(MRM) and support vector machine (SVM) model. The 10-fold cross validation was used as the evaluation method. In order to improve the prediction performance, the data reduction was performed by correlation analysis and new factor were extracted from measured data to improve the reliability of training data. The backpropagation algorithm was used for constructing ANN, multiple regression model was constructed by M5 method. And SVM model was constructed by epsilon-SVM method. As the result showed that the RMSE (Root Mean Squared Error) value of ANN, MRM and SVM were 0.9256, 1.8503 and 7.5521 respectively. In addition, by applying the prediction model to greenhouse heating load calculation, it can increase the income by reducing the energy cost in the greenhouse. The heating load of the experimented greenhouse was 3326.4kcal/h and the fuel consumption was estimated to be 453.8L as the total heating time is $10000^{\circ}C/h$. Therefore, data mining technology of ANN can be applied to various agricultural fields such as precise greenhouse control, cultivation techniques, and harvest prediction, thereby contributing to the development of smart agriculture.

Digital variable structure control of a hot-water heating control system with long dead time (긴 지연시간을 갖는 온수난방 제어시스템의 디지틀 가변구조제어)

  • 안병천;장효환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.232-237
    • /
    • 1991
  • Digital Variable Structure Controller(DVSC) is proposed to control variable speed recirculating pump for hot-water heating control system. In this study, nonlinear sliding line is used beyond output error boundary layer and PID sliding line is used within the layer. For long dead time compensation, constraint is added to Smith predictor algorithm. Steady state error is eliminated by using the proposed sliding line in spite of heating load change. By decreasing sampling time, good sliding motion is yielded but system output noise bv flow dynamics is amplified.

  • PDF

공동주택 최초 지역냉방시스템 현장

  • Park, Jeong-Mi
    • The Magazine for Energy Service Companies
    • /
    • s.42
    • /
    • pp.30-31
    • /
    • 2006
  • 경기도 안산시 사동 푸른마을 3단지 주민들은 남들이 쓰는 에어컨 비용의 3분의 1만 내고도 원하는 시간에 에어컨을 사용하고 쾌적함까지 맛보고 있다. 바로 지역냉장시스템 덕분이다. 이 시스템은 공동주택으로서는 전국 최초로 시범설치된 것으로 하절기 소각열 등 버려지는 열을 이용해 에너지비용을 절감하면서도 프레온가스를 사용하지 않아 친환경적이다. 이 사업은 지난 2001년부터 안산지역에 지역난방을 공급하고 있는 안산도시개발(주)이 시행되고 있다.

  • PDF

ESCO탐방-(주)케너텍

  • Oh, Hae-Eun
    • The Magazine for Energy Service Companies
    • /
    • s.46
    • /
    • pp.22-25
    • /
    • 2007
  • 아파트 소형 열병합발전시스템을 국내에 처음으로 도입한 (주)케너텍(대표 정복임,신동오)은 ESCO 시장에서 항상 두각을 나타내고 있는 중소기업 대표로 통한다. 업계 대기업과 비교해도 손색이 없을만큼 많은 실적을 쌓아온 케너텍은 열병합발전시설의 '24시간 연속난방 시스템'을 가장 먼저 도입, 기술력에서도 높은 평가를 받고 있다. 최근에는 임목폐기물등 버려지는 자원을 연료로 활용한 바이오매스 열병합발전사업을 주도하고있다. 친환경에너지, 해외자원개발 분야에까지 사업을 확장하고 있는 (주)케너텍을 찾았다.

  • PDF

A Study on the Estimation of Adhesive Stability of Organic.Inorganic Mixed Tile Bond to Ondol-Heating Floor System (온돌난방 바닥에 적용하기 위한 유기.무기질 혼합계 타일접착제 종류에 따른 부착 안정성 평가연구)

  • Jung, Yang-Hee;Jung, Eun-Hye;Seo, Sin-Seok;Jeong, Jae-Soo;Kim, Ook-Jong;Lee, Do-Bum
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.99-102
    • /
    • 2009
  • This paper is to present the performance data for pressure setting method using some tile bonds for application on the Ondol-Heating floor system. For this purpose, powder and liquid tile bonds(Organic.Inorganic mixed tile bonds) were compared with the conventional tile cement for pressure setting method in the sight of the adhesive stability of porcelain tile. It tested for tiles after 14, 28days under standard condition and severe conditions. The severe conditions were water immersion and heat ageing($70^{\circ}C$). Another experimental factors concerned tile bond properties such as mixing ratio(in case of using liquid admixture), open time, which are supposed to affect the tensile strength of tile, were studied and discussed through the experiments.

  • PDF

원자력발전소의 Y2K 문제 대응 현황

  • 이규봉
    • JOURNAL OF ELECTRICAL WORLD
    • /
    • s.268
    • /
    • pp.25-29
    • /
    • 1999
  • 우리 국민에게 2000년은 야누스의 두 얼굴로 다가오고 있다. 새로운 천년에 대한 희망의 얼굴과, 세기말 대재양론에 Y2K문제까지 가세하여 불안함을 감추지 못하는 절망의 얼굴이다. 일부 종교단체나 예언가들은 Y2K문제로 인해 지구의 종말이 온다고 믿고서 피난처를 만들고 있으며 인터넷망 등을 이용, 지지세력의 확장을 꾀하고 있다. 그러나 우리는 이에 편승하여 인류의 미래를 이들에게 맡길 것이 아니라, Y2K문제의 실상을 정확히 이해하고 지혜로운 대처를 위해 모든 역량을 결집해야 할 것이다. Y2K문제는 개인용 컴퓨터에서부터 금융, 통신, 전력, 행정전산망 등 국가산업 전반에 영향을 미칠 뿐 아니라 모든 국민의 생활과 직결되는 문제이기 때문이다. 특히 안전성이 생명인 원자력 발전소에서의 Y2K문제는 모든 국민과 언론의 집중적인 관심의 대상이 되고 있다. 이 같은 관심과 우려의 표명은 원전의 특성을 고려할 때 당연한 현상이지만, 2000년이 되면 원전이 불시에 정지되고 큰 사고가 발생할 것이라는 일부의 시각은 국민의 불안만 가중시킬 뿐이다. 결론부터 말하자면 이러한 우려는 기우에 불과하다. 예를 들면 은행 전산망에서 이자를 계산할 때는 날짜가 필수적이다. 그러나 일반 산업 자동화 설비와 마찬가지로 24시간 연속 가동되는 원자력발전소를 운전 할 때는 미리 일정한 값으로 입력된 각종 운전자료, 즉 온도, 압력, 유량 등과 매순간 생성되는 운전자료들을 단순 비교하기 때문에 날짜가 필요치 않다. 이는 마치 실내 난방온도를 일정 값으로 미리 정해놓으면, 그때 그때의 실내온도와 미리 정해진 온도를 비교하여 난방기가 자동으로 작동되는 방식과 같다. 따라서 운전과 직접 관련되는 설비는 Y2K와 관련이 없고, 운전 편의를 위한 데이터취득설비 일부와 방사능 계측 등의 측정장비에 Y2K영향이 있다. 한전에서는 이들 문제의 적시 해결을 위해 충분한 예산과 인력을 확보하여 문제를 해결하는 과정에 있으며 3월 현재 약 70$\%$의 공정을 보이고 있다.

  • PDF

Qualitative analysis of some kinds of petroleum (thinner, gasoline, kerosene, and diesel oil) by gas chromatography (기체 크로마토그래피를 이용한 몇 가지 석유류(시너, 휘발유, 등유 및 경유)의 정성분석)

  • Hyun, Joon-Ho;Park, Jong-Heon;Kim, Sang-Soo;Choi, Jong-Moon
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • The evidence containing some kind of petroleum at the fire spot was analyzed by gas chromatography to identify a fire's sources. To extract some petroleum from fire evidence, 10.0 mL of n-hexane was added in this solution, and it was shaken for 30 minutes. To identify a kind of petroleum in fire evidence, the prepared n-hexane solution was injected and analyzed in the gas chromatograph. The chromatogram of sample was different from those of thinner and gasoline that have low boiling point, and shown different peak pattern to heating and boiler oils. But it was similar to the chromatogram of diesel oil. After small amount of diesel oil was added to the sample, the area of characteristic peaks was increased more than those of raw sample. From the results, the kind of petroleum in the fire evidence was diesel oil.