• Title/Summary/Keyword: 낙뢰율

Search Result 8, Processing Time 0.025 seconds

Lightning Characteristics and Lightning Rate Evaluation of Wind Farm by Lightning of Jeju Island for 2008-2012 (2008-2012년의 제주지역 낙뢰 특성 및 낙뢰에 의한 풍력단지 낙뢰율 평가)

  • Han, Ji-Hoon;Ko, Kyung-Nam;Huh, Jong-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.60-68
    • /
    • 2013
  • This paper presents the characteristics of lightning over established and scheduled wind farms of Jeju island as well as over specific range of entire Jeju Island. The lightning data for 5 years from 2008 to 2012 was obtained from IMPACT ESP which detects lightning. Lightning frequency, lightning strength and regional lightning events were analyzed in detail, and then the lightning maps of Jeju Island were created. The evaluation of lightning rate was made for all the wind farms of this study. Damage to wind turbines by lightning was found in the existing wind farms. As a result, the eastern part of Jeju Island had more lightning frequency than the western part of the Island. Also, the evaluation of lightning rate was good for all established and scheduled wind farms of Jeju Island. Hankyung is the best place for lightning safety, while precaution should be taken against lightning damage in Kimnyung. Lightning damage to wind turbines occurred in Samdal and Haengwon wind farms, which had the first and the second highest lightning rate of the five existing wind farms.

Statistical Characteristics of Recent Lightning Occurred over South Korea (최근 남한지역에서 발생한 낙뢰의 통계적 특성)

  • Eom, Hyo-Sik;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.30 no.2
    • /
    • pp.210-222
    • /
    • 2009
  • Lightning data, observed from total lightning detection system (TLDS) of KMA, for the recent five years (2002-2006) have been analyzed for temporal and spatial characteristics of frequency, intensity, duration, and flash rate. Lightning frequency varies largely with years (most frequent in 2006) and the lightning during the summer accounts for 75% of total flashes and only 0.6% of lightnings strike in cold season. In rainy season (JJAS), the ratio of positive flashes to negative ones is as low as 0.15, but it increases up to 0.98 in February. The seasonal variation of lightning duration is strongly linked with lightning occurrences, whereas flashes rates show weak seasonal variability. In a daily scale, lightning, on average, occurs more often at dawn (2 am, 5-7 am) and in the mid-afternoon (15 pm), and the lightning at dawn (around 5 am) is most intense during the day. The western inland areas md the West/South Sea show high lightning density during JJAS, whereas eastern part and the East Sea exhibit a low density of lightning. Considering the low ratio of positive flashes (0.15) for the whole analysis domain during summer period, Chungnam and Jeonbuk areas have a high ratio of flashes over 0.4. However, these should be analyzed with much caution because weak positive cloud-to-cloud discharges can be regarded as cloud-to-ground flashes. The western inland also exhibits long annual flash hours (15-24). And the W3st Sea has high flash rates as a result of large density and low flash hours. The most frequent time of lightning occurrence over most inland areas lies between mid-afternoon and early-evening, whereas mountainous and coastal areas, and the northern Kyoungki and Hwanghae provinces show the maximum lightning strikes in the morning and at dawn, respectively.

Research on the Electromagnetic Analysis Method of Indirect Effects on a High-Conductive Structure Exposed by Lightning (낙뢰에 노출된 높은 도전성 구조체의 간접적 영향 분석을 위한 전자파 해석기법 연구)

  • Cho, Jeahoon;Lee, Jinho;Tae, Hyun-Sung;Jung, Kyung-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.11
    • /
    • pp.1012-1018
    • /
    • 2016
  • We perform a electromagnetic analysis method for indirect effects of a high-conductive structure such as an aircraft exposed by lightning, by using the finite-difference time-domain(FDTD) method. The lightning waveform used to analyze indirect effects has low frequency spectrum and high-conductive materials such as aluminum and carbon fiber composite materials have very short skin depths, and thus, it requires large memory and long computation time using conventional three dimensional FDTD analysis method. We develop an efficient electromagnetic analysis method suitable for lightning and high-conductive structures. The developed analysis method is based on two dimensional FDTD and impedance network boundary condition(INBC) algorithms and we investigate the indirect effects on the structures exposed to lightning.

Effects of Fertilizer Levels and Plant Densities on Flowering and Bolling in Cotton (시비량과 재식밀도가 목화의 개화 및 결삭에 미치는 영향)

  • 김상곤;박홍재;성병열;정동희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.5
    • /
    • pp.436-441
    • /
    • 1992
  • This study was carried out to discuss the influences of the different fertilizer levels and plant densities on the flowering and balling in cotton in Mokpo Branch Station, Crop Experiment Station in 1991. The cotton flowered 67% before Aug. 25 which is the limit date of picked-cotton harvest, and the ratio of flowering for stalk-cut cotton was 30%. The 1.5 times fertilizer levels and the 70cm row density had more flower buds, flowers and bolls per m$^2$ than any other treatment plot. The crop growing was bad in dense planting due to the nutrient deficiency. The flowering ratio to flower bud was about 70%, and the balling ratio to flower numbers was about 48%. The bolling ratio was lower in the case of more flower number. The shedding ratio of flower buds was about 30% in average and showed increasing tendency by dense planting. It was observed that the higher ratio of bud shedding tended to accompany with shedding the lower ratio of boll shedding.

  • PDF

Alleviation of Low and High Temperature Injury in Tomato Plants by Uniconazole (Uniconazole처리가 토마토의 저온 및 고온 피해 경감에 미치는 효과)

  • Ku, Ja Hyeong;Lee, Young Bok
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.2
    • /
    • pp.86-94
    • /
    • 2000
  • This study was carried out to determine the effectiveness of uniconazole in ameliorating low and high temperature injury in tomato plants(Lycopersicon esculentum Mill. cvs. Fireball and Patio). Plants were given a soil drench of 0, 0.001, 0.01 or $0.1mg{\cdot}pot^{-1}$ uniconazole, and after 14 days, were treated with 12-h day/12-h night cycles at $25/25^{\circ}C$, $2.5/25^{\circ}C$, $25/2.5^{\circ}C$ or $40/40^{\circ}C$ for 4 days in controlled-environment chamber. Number of damaged leaves per plant, reduction of stem elongation, and overall injury were high at $2.5/25^{\circ}C$, but more reduction of leaf elongation, delay of flowering, and abortion of floral bud were observed in plants at $40/40^{\circ}C$. There was difference in degree of injury between cultivars, thus, 'Fireball' was much affected by unfavorable temperature regimes. All concentrations of uniconazole reduced leaf and stem elongation, increased total chlorophyll concentration, delayed flowering, and significantly provided protection against low and high temperature injury in two cultivars. In general, the application of uniconazole did not inhibit flowering delay and floral bud abortion induced by high and low temperature exposure. Our results support the hypothesis that the role of uniconazole is related to defense system against oxidative stress induced by low temperature stress. Further research is required to clarifu the phytoprotective mechanism of this compound agaist high temperature stress.

  • PDF

A study on the Site Survey and Detection Efficiency for Kepco Lightning Detection and Information Network (낙뢰측정 네트워크(KLDNet)를 위한 감지기 사이트서베이와 낙뢰 감지율 검토)

  • Woo, J.W.;Kwak, J.S.;Moon, J.D.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.532-537
    • /
    • 2006
  • Lightning induced faults accounts for more than 66% at the transmission lines of KEPCO. The lightning causes damages to power system equipments including transmission line, the blackout of electricity and the electro-magnetic interference. Because of this reason, we need the real time lightning information for the optimal operation of power system. And, it is required to obtain and accumulate the lightning current parameters for the insulation design. In 2005, KEPRI constructed a lightning detection network, the KLDNet (i.e. Kepco Lightning Detection & Information System) and launched a lightning information service for KEPCO customers. It is intended to provide data service on the operation of transmission lines and collect lightning-related data, which is the most important factor regulating power system design and operation. The new system will replace LPATS, the old detection system, which has been operating since 1995 and is rapidly failing in terms of both detection performance and location accuracy. The purpose of this paper is to explain the work performed and the results of that work in performing a site survey of several locations. The purpose of the site survey is to find locations acceptable for the installation of a lightning location receiver in support of a Lightning detection system(LDS). A restriction was placed on the surveyed locations, as they must belong to the Korea Electric Power Company. This requirement was made to facilitate the communication needs of the LDS network. Total of 15 sites were evaluated as possible LDS sensor sites. Some of the sites were rejected for physical reasons and therefore no electrical testing was performed. Of the 15 sites, total of 10 sites were considered acceptable and 5 sites were rejected for various reason. In this paper, we would like to explain the site survey and detection efficiency for LDS.

Insulation Coordination on 22.9kV HTS Power Cable for Applying to Real Grid (22.9kV 초전도 케이블 실계통 적용을 위한 절연협조 검토)

  • Yang, B.M.;Kang, J.W.;Kang, Y.W.;Park, J.W.;Jo, H.S.;Kim, T.H.;Jung, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.497-498
    • /
    • 2011
  • 초전도 케이블을 실계통에 연계한 계통이 운용되고 있으므로 인해 많은 계통 과도현상의 모델링이 필요하다. 초전도 전력기기의 특성을 고려한 계통영향 분석을 통해 향후 초전도 기기의 확대 보급을 위한 적용기술 기반 확보가 필요하다. 그래서 본 논문에서는 초전도케이블의 실계통 적용을 위해서 이천변전소에 시범 적용된 초전도케이블 계통을 대상으로 전력계통의 뇌격 침입에 의한 계통의 과전압 현상을 파악하기 위한 전력계통 모델링 및 계통모의를 실시하였다. 최근 낙뢰로 인한 전력계통의 고장율도 증대되고 이로 인한 피해도 증가되고 있어, 향후 실계통 적용될 초전도 전력기기에 대한 과전압 특성에 대한 기술적 분석은 반드시 요구되고 있다.

  • PDF

Characteristics of Flowering and Bolling in Cotton (목화의 개화 및 결삭 특성)

  • 박홍재;김철우;김상곤;정동희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.3
    • /
    • pp.201-207
    • /
    • 1993
  • This study was carried out to ascertain the flowering and boiling habits in conditions of vinyl mulched cultivation. The effects of vinyl mulching cultivation in cotton was early flowering. The flowering period was no more than 26 days and shedding of flower bud was lower. The total boll setting rate to flower number was about 38%. The number of flowering plants was rapidly increased until Aug. 8, then later was decreased, the period of the highest flowering occured was for 5 days from Aug. 6 to Aug. 10. Boll setting was increased that the flowers opened before July 30, then the later flowers was tended to decrease belling in spite of the increased flowering. However flower bud shedding had a tendency to decrease after the highest boiling period. The effect of weather, max. temperature and hours of sunshine on flowering days were highly positive significant correlation. Minimum temperatures, high air humidity and amount of rainfall had a negative significant correlation. The demanded days to flowering on the same internode in each fruiting branches was taken average 1.2 days, these days among the fruiting branches of the same internode was 3.6 days.

  • PDF