• Title/Summary/Keyword: 기초안정성 평가

Search Result 478, Processing Time 0.03 seconds

Liquefaction in Seabeds and Stability of Coastal Structure Foundations (해저지반의 액상화와 해안구조물 기초의 안정성)

  • Kang, Hong-Yoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.143-152
    • /
    • 1998
  • 해안구조물 설치시 기초지반의 안정성 해석을 위한 파랑에 기이한 액상화 메카니즘을 과잉간극수압(excess pore pressure) 현상과 관련하여 논의하였다. 과잉간극수압 발생 메커니즘에 있어서 두 가지 형태, 즉 변동과잉간극수압 (Oscillatory excess pore pressure) 및 잔류과잉간극수압 (Residual excess pore pressure) 각각에 기인한 액상화의 특성을 구명하였다. 또한, 과잉간극수압 및 해저지반의 액상화 가능성에 대한 평가공정을 제시하였는데 이는 모형실험과 현장관측자료에 의해 그 적용성이 검증되었다. 이러한 평가공정(Assessment Procedures)은 투수성 해저/기초 지반의 액상화를 추정하는데 이용될 수 있다. 해안구조물 기초 설계 및 해저 지반의 안정성 평가시 액상화의 가능성 또는 과잉간극수압의 적절한 평가.고려가 무엇보다 중요하다고 사료된다.

  • PDF

Stability Evaluation Along Interface Loss of a Foundation and the Ground (기초와 지반의 접촉면 손실에 따른 지지력 안정성 평가)

  • Kim, Sang-Hwan;Ji, Tal-Oh
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.178-185
    • /
    • 2010
  • This paper presents the evaluation of foundation stability according to decrease of the foundation contact area on the ground. In order to carry out this research, the experimental and numerical studies are performed. In the experimental study, the carefully controled laboratory model tests are carried out with different foundation size and types. The model test results are analyzed and interpreted by analytical and numerical calculation in order to verify both results obtained from experimental and numerical studies. It is clearly found from the results that the foundation stability is considerably reduced when the foundation contact area ratio is less than 75%. This research may be very useful to develop the economical foundation type.

Field Applicability Evaluation of Foundation Combine with Footing and Pile by Model Test (모형실험을 통한 복합기초의 현장 적용성 평가)

  • Kim, Hak-Moon;Jang, Kyung-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3729-3744
    • /
    • 2011
  • As the size of structures become larger by civil and architectural structures becoming large, deeply underground, and high-rise, the conditions of underground foundation vary according to the location that the lack of bearing capacity locally because of ununiform of foundation in some parts is frequent. Generally, when the foundation is not homogeneous, the acquisition of safety through applying the most conservative foundation method possible becomes the focus to secure the stability of the superstructures. It is considered as because of inability to verify the application and stability and application of construction of different foundations through an outlined review because of lack of study in case of different foundation of mixed use of direct foundation and pile foundation. Therefore, through measurement interpretation of the different foundation in which the direct foundation and pile foundation are mixed in use, the grounds in which the hypothetical bearing capacity changes dramatically was modeled to evaluate the applicability of different foundations. Also, based on the results of measurement interpretation, various foundations are created by using plaster, Joomunjin standard soil, and rubble to conduct an indoor model test to compare and analyze the movement of pile foundation and different foundations. Based on such research results, the stability and applicability of the different foundations which is more efficient and economical than the existing foundations in case of grounds in which the bearing capacity changes dramatically by comparing and analyzing the different foundations (direct foundation + pile foundation) with the conservative pile foundation and mat foundation. As a result, when the different foundation is applied, the overall settlement amount increased than the conservative pile foundation. However, the difference was very minute and it has been confirmed to be no issue as a result of assessment of stability of the differential settlement of structures through critical angle displacement.

The Numerical Analysis for Different Foundations Constructed by Footing and Pile (직접기초와 파일기초로 적용된 이질기초에 대한 수치해석적 평가)

  • Hwang, Eui-Suk;Jang, Kyung-Jun;Thak, Ki-Yoel;Lee, Jong-Sung;Kim, Hak-Moon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.985-992
    • /
    • 2009
  • 대형 구조물의 기초 시공 시 구조물의 하부지반이 불균질하거나 경사진 지반 또는 일반토사와 암반이 혼재된 지지력이 급격히 변화하는 구간에서 시공되는 경우가 많으며 이와 같은 경우에는 경제적인 최적의 방안으로 직접기초와 말뚝기초를 혼용하여 사용하는 방안이 필요하다. 그러나 일반적으로 기초의 안정성 확보를 위해 보수적으로 말뚝기초를 적용하는 경우가 대부분이며 소규모의 아파트 기초현장에서는 부분적으로 이질기초가 적용되나 이에 대한 보강이나 안정성 검토는 형식적으로 이루어지는 경우가 대부분이다. 본 연구에서는 직접기초와 파일기초가 적용되는 이질기초에 대한 수치해석을 통하여 이질기초 적용 시 기초 및 하부지반에 대한 거동을 평가하여, 이질기초에 대한 적용가능성 여부 및 기초하부에서의 개략적인 거동에 대하여 고찰하고자 한다.

  • PDF

Stability Evaluation of Shallow Foundation by Plate Bearing Test (PBT에 의한 직접기초의 안정성 평가)

  • Ki Wan-Seo;Joo Seung-Wan;Kim Sun-Hak
    • The Journal of Engineering Geology
    • /
    • v.15 no.4 s.42
    • /
    • pp.423-433
    • /
    • 2005
  • For the design of spread foundation and the stability evaluation, we compared and analyzed it for theoretical, empirical bearing capacity formulas, and various settlement computation formulas, by conducting the plate bearing test at the site of A and B, which consisted of gneiss weathered soil. In addition, we considered the effective method of stability evaluation by carrying out the plate bearing test carried out on the ground consisted of weathering soil of gneiss. Consequently, it was found out that the allowablebearing capacity by the theoretical formula of Terzaghi was too excessive in comparison with the result of the plate bearing test and the Terzaghi-Peck method, which was used widely domestically in designing the spread foundation. It was more effective for a stable design. As a result of the plate bearing test carried out, on the ground consisted of weathering soil. It was found that reviewing the stability by the bearing capacity calculated with load-settlement curve. It is evaluated in a safer side than the point of view of the settlement.

Development of Spatial Information System for Regional Ground Stability Assessment near Dam area (댐 주변지역 광역적 지반 안정성 평가를 위한 공간 정보시스템 개발)

  • 장범수;이사호;최위찬;최재원;오영철
    • Spatial Information Research
    • /
    • v.9 no.1
    • /
    • pp.125-135
    • /
    • 2001
  • Ground failure such as landslide, rock fall land subsidence by heavy rainfall have damaged to people and property. Especially, the damage to important facility such as dam, bridge, tunnel and industrial complex may be possible. Therefore the ground failure must be assessed and counter plan must be prepared. So, the object of this study is to develop the spatial information system for regional ground stability assessment. For this, the topographic, geologic, soil, forest, land use, rainfall frequency map, and satellite image near 40 dams were collected and constructed to the spatial information system. The spatial information system was developed using Avenue in ArcView 3.2 environment and consists of pull down menus and icons. For application of the spatial information system, regional ground stability was assessed in Andong dam. The assessment was ground failure susceptibility and possibility. The spatial information can be used for regional ground stability assessment, prevention and mitigation of hazard, and management of ground as basic data.

  • PDF

Numerical Analysis for Integrity Evaluation of River Bank (하천제방의 건전도 평가를 위한 수치해석적 연구)

  • Jung, Hyuksang;Byun, Yoseph;Chun, Byungsik;Choi, Bonghyuck;Kim, Jinman
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.11
    • /
    • pp.19-26
    • /
    • 2010
  • An influence factors for soundness evaluation of river levee include consisting embankment in case piping, permeability coefficient of ground, height of embankment, the width of crest, material characteristics of embankment and foundation ground, shape of embankment slope, an influence for penetration of rainfall or river water in case slope stability. In this study, it was operated a feasibility investigation of existing design result, stability evaluation for permeability coefficient use and permeability coefficient change of foundation ground to investigate an influence in line with permeability coefficient change for result of river levee penetration analysis. The evaluation results of influence factors, the permeability coefficient was used in design and it was evaluated influence in safety factor of piping. After the evaluation of influence factors, the permeability coefficient used in the design appears with the fact that differs in a design report about same soil.

Assesment on the Characteristics of Foundation Bearing Capacity in Reinforced Soil Wall Structure of Large Scale (대규모 보강토옹벽 구조물에서의 기초지반 지지력특성 평가)

  • Han, Jung-Geun;Yoo, Seung-Kyung;Cho, Sam-Deuk;Lee, Kyang-Woo;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.5 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • The reinforced soil retaining wall structures of serious types with environmental are widely expanding more and more in Korea, which divided conventional type's reinforced soil retaining wall on segmental retaining wall. The causes of most crack occurred at block in reinforced soil retaining wall structure caused by the differential settlement of foundation. It is difference of settlement for significant factor that with overall slope stability. In this study, design assessment of foundation bearing capacity related to differential settlement of foundation ground was considered. And, also, through case study, the countermeasure methods and its application were suggested that the bearing capacity of foundation had to stabilize. The foundation ground in charge of bearing capacity should be affected by the resisting force of sliding, because the foundation parts of reinforced soil retaining wall were belongs to potential slope sliding area in overall stabilizing including retaining wall structures. Therefore, the analyzing or the designing of bearing capacity for foundation should be considered control capacity on the overall slope sliding.

  • PDF